Cytotoxic Effects of Polyhexanide on Cellular Repopulation and Calcification of Decellularized Equine Carotids in vitro and in vivo. Issue 3 (March 2013)
- Record Type:
- Journal Article
- Title:
- Cytotoxic Effects of Polyhexanide on Cellular Repopulation and Calcification of Decellularized Equine Carotids in vitro and in vivo. Issue 3 (March 2013)
- Main Title:
- Cytotoxic Effects of Polyhexanide on Cellular Repopulation and Calcification of Decellularized Equine Carotids in vitro and in vivo
- Authors:
- Böer, Ulrike
Spengler, Claas
Klingenberg, Melanie
Jonigk, Danny
Harder, Michael
Kreipe, Hans-Heinrich
Haverich, Axel
Wilhelmi, Mathias - Abstract:
- Purpose: Disinfection of biological implants is indispensable for clinical safety. Here, decellularized equine carotid arteries (dECAs) were disinfected by polyhexanide (PHX), an effective, well-tolerated and nontoxic wound disinfectant and evaluated as vascular grafts for their repopulation and local biocompatibility in vivo. Methods: dECAs were terminally disinfected by a combination of 0.1% PHX and 70% ethanol (dECA_PHX-ET) or exclusively ethanol (dECA-ET) and subsequently implanted as arteriovenous shunts in sheep for 14 weeks. Repopulation was determined by immunohistochemistry for endothelial- (ECs) or smooth muscle cells (SMCs) using antibodies against CD31 and smooth muscle actin. Histological evaluation was performed on HE-stained sections. Cytotoxicity of dECAs was measured directly by seeding the scaffolds with L-929 fibroblasts, which were visualized by calcein staining. Indirect cytotoxicity was determined by WST-8 viability assay by incubation of L-929 with dECA extracts. Results: dECA_PHX-ET completely lacked repopulation with ECs and SMCs, showed leukocyte infiltration, strong calcification and poor neovascularization indicating insufficient biocompatibility and inflammatory graft degeneration. PHX-treatment reduced cell viability to 33.2 ± 12.6% and disturbed cell growth at direct contact. In contrast, dECA_ET had no direct cytotoxic effect and only slightly influenced cell viability (82.9 ± 12.5%), showed a substantial repopulation by ECs and SMCs includingPurpose: Disinfection of biological implants is indispensable for clinical safety. Here, decellularized equine carotid arteries (dECAs) were disinfected by polyhexanide (PHX), an effective, well-tolerated and nontoxic wound disinfectant and evaluated as vascular grafts for their repopulation and local biocompatibility in vivo. Methods: dECAs were terminally disinfected by a combination of 0.1% PHX and 70% ethanol (dECA_PHX-ET) or exclusively ethanol (dECA-ET) and subsequently implanted as arteriovenous shunts in sheep for 14 weeks. Repopulation was determined by immunohistochemistry for endothelial- (ECs) or smooth muscle cells (SMCs) using antibodies against CD31 and smooth muscle actin. Histological evaluation was performed on HE-stained sections. Cytotoxicity of dECAs was measured directly by seeding the scaffolds with L-929 fibroblasts, which were visualized by calcein staining. Indirect cytotoxicity was determined by WST-8 viability assay by incubation of L-929 with dECA extracts. Results: dECA_PHX-ET completely lacked repopulation with ECs and SMCs, showed leukocyte infiltration, strong calcification and poor neovascularization indicating insufficient biocompatibility and inflammatory graft degeneration. PHX-treatment reduced cell viability to 33.2 ± 12.6% and disturbed cell growth at direct contact. In contrast, dECA_ET had no direct cytotoxic effect and only slightly influenced cell viability (82.9 ± 12.5%), showed a substantial repopulation by ECs and SMCs including neovascularization, and were only slightly calcified. Conclusion: The disinfectant polyhexanide seems to exert severe cytotoxic effects when used for the processing of decellularized matrices and may result in degenerative graft deterioration. In contrast, dECAs exclusively disinfected with ethanol were well integrated. Thus, ethanol seems to be a more suitable tool for graft processing than polyhexanide. … (more)
- Is Part Of:
- International journal of artificial organs. Volume 36:Issue 3(2013)
- Journal:
- International journal of artificial organs
- Issue:
- Volume 36:Issue 3(2013)
- Issue Display:
- Volume 36, Issue 3 (2013)
- Year:
- 2013
- Volume:
- 36
- Issue:
- 3
- Issue Sort Value:
- 2013-0036-0003-0000
- Page Start:
- 184
- Page End:
- 194
- Publication Date:
- 2013-03
- Subjects:
- Tissue-engineered vascular graft -- Blood vessel prothesis implantation -- Guided tissue generation -- Biocompatibility testing -- Endothelial cells
Artificial organs -- Periodicals
617.956 - Journal URLs:
- http://catalog.hathitrust.org/api/volumes/oclc/3676874.html ↗
http://www.artificial-organs.com/ ↗
http://www.wichtig-publisher.com/jao/ ↗
http://www.uk.sagepub.com/home.nav ↗
http://journals.sagepub.com/loi/jaoa ↗
https://us.sagepub.com/en-us/nam/the-international-journal-of-artificial-organs/journal203459 ↗ - DOI:
- 10.5301/ijao.5000182 ↗
- Languages:
- English
- ISSNs:
- 0391-3988
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24549.xml