Implementation of pencil beam redefinition algorithm (PBRA) for intraoperative electron radiation therapy (IOERT) treatment planning. (December 2022)
- Record Type:
- Journal Article
- Title:
- Implementation of pencil beam redefinition algorithm (PBRA) for intraoperative electron radiation therapy (IOERT) treatment planning. (December 2022)
- Main Title:
- Implementation of pencil beam redefinition algorithm (PBRA) for intraoperative electron radiation therapy (IOERT) treatment planning
- Authors:
- Tavallaie, Mina
Hariri Tabrizi, Sanaz
Heidarloo, Nematollah - Abstract:
- Highlights: Pencil Beam Redefination Algorithm (PBRA) was implemented with three initialization methods and compared to MC. Phase space distribution of the electrons below the applicator was generated using MC simulation. The agreement between PBRA dose calculation and MC is promising for development of an intraoperative TPS for IOERT. Abstract: Purpose: Similar to other radiation therapy techniques, intraoperative electron radiation therapy (IOERT) can benefit from an online treatment planning system (TPS). Among all the analytical electron dose calculation algorithms, pencil beam redefinition algorithm (PBRA) has shown an acceptable accuracy in inhomogeneities. The input dataset for PBRA includes electron planar fluence, mean direction and root mean square (RMS) spread about the mean direction which had been introduced based on the conventional linear accelerator geometry in former studies. Herein, three methods for implementing PBRA for IOERT system are presented. Methods: The initialization parameters were identified using Monte Carlo (MC) simulation of a dedicated IOERT system equipped with a cylindrical 10 cm applicator, irradiating a water phantom. Phase space distribution of electrons was recorded on a plane below the applicator. The input dataset was extracted for 2 × 2 mm 2 pixels and energy bin width of 1 MeV. Results: PBRA was implemented with three initialization methods and compared to MC. The 3D gamma analysis of the algorithm with the Formula method, whichHighlights: Pencil Beam Redefination Algorithm (PBRA) was implemented with three initialization methods and compared to MC. Phase space distribution of the electrons below the applicator was generated using MC simulation. The agreement between PBRA dose calculation and MC is promising for development of an intraoperative TPS for IOERT. Abstract: Purpose: Similar to other radiation therapy techniques, intraoperative electron radiation therapy (IOERT) can benefit from an online treatment planning system (TPS). Among all the analytical electron dose calculation algorithms, pencil beam redefinition algorithm (PBRA) has shown an acceptable accuracy in inhomogeneities. The input dataset for PBRA includes electron planar fluence, mean direction and root mean square (RMS) spread about the mean direction which had been introduced based on the conventional linear accelerator geometry in former studies. Herein, three methods for implementing PBRA for IOERT system are presented. Methods: The initialization parameters were identified using Monte Carlo (MC) simulation of a dedicated IOERT system equipped with a cylindrical 10 cm applicator, irradiating a water phantom. Phase space distribution of electrons was recorded on a plane below the applicator. The input dataset was extracted for 2 × 2 mm 2 pixels and energy bin width of 1 MeV. Results: PBRA was implemented with three initialization methods and compared to MC. The 3D gamma analysis of the algorithm with the Formula method, which was in best agreement with MC in a simple water phantom, showed passing rates of more than 99 % for all nominal energies and it was 97.1 % for 8 MeV in the presence of protecting disk and irregular surface. Implementing PBRA on CUDA C++ resulted in 5 s run time for 8 MeV nominal energy in a water phantom. Conclusions: The agreement between PBRA dose calculation and MC is promising for the development of an intraoperative TPS for IOERT. … (more)
- Is Part Of:
- Physica medica. Volume 104(2023)
- Journal:
- Physica medica
- Issue:
- Volume 104(2023)
- Issue Display:
- Volume 104, Issue 2023 (2023)
- Year:
- 2023
- Volume:
- 104
- Issue:
- 2023
- Issue Sort Value:
- 2023-0104-2023-0000
- Page Start:
- 32
- Page End:
- 42
- Publication Date:
- 2022-12
- Subjects:
- Intraoperative electron radiation therapy (IOERT) -- Pencil beam redefinition algorithm (PBRA) -- Treatment planning
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2022.10.015 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24544.xml