Safety and Effectiveness of Vessel Sealing for Dissection during Pancreaticoduodenectomy. Issue 3 (March 2013)
- Record Type:
- Journal Article
- Title:
- Safety and Effectiveness of Vessel Sealing for Dissection during Pancreaticoduodenectomy. Issue 3 (March 2013)
- Main Title:
- Safety and Effectiveness of Vessel Sealing for Dissection during Pancreaticoduodenectomy
- Authors:
- Pointer, David T.
Slakey, Lauren M.
Slakey, Douglas P. - Abstract:
- Traditional pancreaticoduodenectomy dissection techniques are tedious and time-consuming. The LigaSure® Vessel Sealing System is an alternative to standard dissection methods. LigaSure® can be used in replace of ligatures, clips, and sutures in most of the pancreaticoduodenectomy procedure. The objective of this study was to examine our experience with LigaSure® in pancreaticoduodenectomies and to show the safety and time-effectiveness. Forty-three pancreaticoduodenectomies were performed by a single surgeon using the LigaSure® device in place of traditional dissection techniques. A retrospective chart review was conducted to evaluate patient management and outcome. Demographics, preoperative, intraoperative, and postoperative data were analyzed. The average patient age was 61 years. Primary pathologic diagnoses were: periampullary carcinoma (56%), chronic pancreatitis (5%), cystic lesion (26%), neuroendocrine tumor (7%), and other (5%). Our patient population demonstrated American Society of Anesthesiologists Class I (2%), Class II (14%), III (75%), and IV (9%). Average operative time was 4:11 hours. The study group required an average of 0.49 ± 1.35 units of blood. Eight patients (19%) received blood transfusion, receiving an average of 2.63 ± 2.13 units. Patients had a median hospital stay of 10 days (range, 5 to 41 days). An oral diet was ordered for most patients by Day 4. Fourteen patients (32.5%) had a complication, including two patients requiring additional surgeryTraditional pancreaticoduodenectomy dissection techniques are tedious and time-consuming. The LigaSure® Vessel Sealing System is an alternative to standard dissection methods. LigaSure® can be used in replace of ligatures, clips, and sutures in most of the pancreaticoduodenectomy procedure. The objective of this study was to examine our experience with LigaSure® in pancreaticoduodenectomies and to show the safety and time-effectiveness. Forty-three pancreaticoduodenectomies were performed by a single surgeon using the LigaSure® device in place of traditional dissection techniques. A retrospective chart review was conducted to evaluate patient management and outcome. Demographics, preoperative, intraoperative, and postoperative data were analyzed. The average patient age was 61 years. Primary pathologic diagnoses were: periampullary carcinoma (56%), chronic pancreatitis (5%), cystic lesion (26%), neuroendocrine tumor (7%), and other (5%). Our patient population demonstrated American Society of Anesthesiologists Class I (2%), Class II (14%), III (75%), and IV (9%). Average operative time was 4:11 hours. The study group required an average of 0.49 ± 1.35 units of blood. Eight patients (19%) received blood transfusion, receiving an average of 2.63 ± 2.13 units. Patients had a median hospital stay of 10 days (range, 5 to 41 days). An oral diet was ordered for most patients by Day 4. Fourteen patients (32.5%) had a complication, including two patients requiring additional surgery for drainage of abscess. There were no postoperative deaths. The use of LigaSure® is a practical and safe alternative to standard dissection techniques. Operative time, blood loss, and complication rate are favorable compared with published series. … (more)
- Is Part Of:
- American surgeon. Volume 79:Issue 3(2013)
- Journal:
- American surgeon
- Issue:
- Volume 79:Issue 3(2013)
- Issue Display:
- Volume 79, Issue 3 (2013)
- Year:
- 2013
- Volume:
- 79
- Issue:
- 3
- Issue Sort Value:
- 2013-0079-0003-0000
- Page Start:
- 290
- Page End:
- 295
- Publication Date:
- 2013-03
- Subjects:
- Surgery -- Periodicals
Surgery -- United States -- Periodicals
617.0973 - Journal URLs:
- https://journals.sagepub.com/home/asua ↗
http://www.sagepublications.com/ ↗ - DOI:
- 10.1177/000313481307900329 ↗
- Languages:
- English
- ISSNs:
- 0003-1348
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24543.xml