High‐resolution in vivo monophasic gastric slow waves to quantify activation and recovery profiles. Issue 12 (20th June 2022)
- Record Type:
- Journal Article
- Title:
- High‐resolution in vivo monophasic gastric slow waves to quantify activation and recovery profiles. Issue 12 (20th June 2022)
- Main Title:
- High‐resolution in vivo monophasic gastric slow waves to quantify activation and recovery profiles
- Authors:
- Han, Henry
Cheng, Leo K.
Paskaranandavadivel, Niranchan - Abstract:
- Abstract: Background: Gastric bio‐electrical slow waves are, in part, responsible for coordinating motility. Spatial dynamics about the recovery phase of slow wave recordings have not been thoroughly investigated due to the lack of suitable experimental techniques. Methods: A high‐resolution multi‐channel suction electrode array was developed and applied in pigs to acquire monophasic gastric slow waves. Signal characteristics were verified against biphasic slow waves recorded by conventional surface contact electrode arrays. Monophasic slow wave events were categorized into two groups based on their morphological characteristics, after which their amplitudes, activation to recovery intervals, and gradients were quantified and compared. Coverage of activation and recovery maps for both electrode types were calculated and compared. Key Results: Monophasic slow waves had a more pronounced recovery phase with a higher gradient than biphasic slow waves (0.5 ± 0.1 vs. 0.3 ± 0.1 mV·s −1 ). Between the 2 groups of monophasic slow waves, there was a significant difference in amplitude (1.8 ± 0.5 vs. 1.1 ± 0.2 mV), activation time gradient (0.8 ± 0.2 vs. 0.3 ± 0.1 mV·s −1 ), and recovery time gradient (0.5 ± 0.1 vs. 0.3 ± 0.1 mV·s −1 ). For the suction and conventional contact electrode arrays, the recovery maps had reduced coverage compared to the activation maps (4 ± 6% and 43 ± 11%, respectively). Conclusions and Inferences: A novel high‐resolution multi‐channel suction electrodeAbstract: Background: Gastric bio‐electrical slow waves are, in part, responsible for coordinating motility. Spatial dynamics about the recovery phase of slow wave recordings have not been thoroughly investigated due to the lack of suitable experimental techniques. Methods: A high‐resolution multi‐channel suction electrode array was developed and applied in pigs to acquire monophasic gastric slow waves. Signal characteristics were verified against biphasic slow waves recorded by conventional surface contact electrode arrays. Monophasic slow wave events were categorized into two groups based on their morphological characteristics, after which their amplitudes, activation to recovery intervals, and gradients were quantified and compared. Coverage of activation and recovery maps for both electrode types were calculated and compared. Key Results: Monophasic slow waves had a more pronounced recovery phase with a higher gradient than biphasic slow waves (0.5 ± 0.1 vs. 0.3 ± 0.1 mV·s −1 ). Between the 2 groups of monophasic slow waves, there was a significant difference in amplitude (1.8 ± 0.5 vs. 1.1 ± 0.2 mV), activation time gradient (0.8 ± 0.2 vs. 0.3 ± 0.1 mV·s −1 ), and recovery time gradient (0.5 ± 0.1 vs. 0.3 ± 0.1 mV·s −1 ). For the suction and conventional contact electrode arrays, the recovery maps had reduced coverage compared to the activation maps (4 ± 6% and 43 ± 11%, respectively). Conclusions and Inferences: A novel high‐resolution multi‐channel suction electrode array was developed and applied in vivo to record monophasic gastric slow waves. Slow wave recovery phase analysis could be performed more efficiently on monophasic signals compared with biphasic signals, due to the more identifiable recovery phases. Abstract : A novel high‐resolution multi‐channel suction electrode array was developed and applied in vivo to record monophasic gastric slow waves. Spatiotemporal slow wave recovery phase analysis was more reliably performed on monophasic signals compared with the biphasic signals, owing to the defined recovery morphology. … (more)
- Is Part Of:
- Neurogastroenterology & motility. Volume 34:Issue 12(2022)
- Journal:
- Neurogastroenterology & motility
- Issue:
- Volume 34:Issue 12(2022)
- Issue Display:
- Volume 34, Issue 12 (2022)
- Year:
- 2022
- Volume:
- 34
- Issue:
- 12
- Issue Sort Value:
- 2022-0034-0012-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2022-06-20
- Subjects:
- gastric dysrhythmias -- multielectrode recordings -- slow waves
Gastrointestinal system -- Motility -- Periodicals
Gastrointestinal system -- Innervation -- Periodicals
616.33 - Journal URLs:
- http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=nmo ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1365-2982 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/nmo.14422 ↗
- Languages:
- English
- ISSNs:
- 1350-1925
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6081.371450
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 24540.xml