Patients with known coronary artery disease who are ruled out for acute myocardial infarction using a high sensitivity troponin T 0/1-hour algorithm have increased 30-day major adverse cardiac events. (3rd October 2022)
- Record Type:
- Journal Article
- Title:
- Patients with known coronary artery disease who are ruled out for acute myocardial infarction using a high sensitivity troponin T 0/1-hour algorithm have increased 30-day major adverse cardiac events. (3rd October 2022)
- Main Title:
- Patients with known coronary artery disease who are ruled out for acute myocardial infarction using a high sensitivity troponin T 0/1-hour algorithm have increased 30-day major adverse cardiac events
- Authors:
- Nowak, R M
O'Neill, J C
Ashburn, N P
Snavely, A C
Paradee, B E
Allen, B R
Christenson, R H
Mumma, B E
Madsen, T
Stopyra, J P
Mahler, S A - Abstract:
- Abstract: Background: The European Society of Cardiology (ESC) 0/1-hour high sensitivity troponin (hs-cTn) algorithm is widely used in the evaluation of patients presenting to the Emergency Department (ED) with symptoms suspicious for non ST-segment elevation myocardial infarction (NSTEMI). There is limited data available for the use of this algorithm comparing NSTEMI rule-out rates and 30-day adverse outcomes in patients with and without known coronary artery disease (CA), defined as prior myocardial infarction [MI], coronary revascularization, or ≥70% coronary stenosis. Purpose: The objective of this secondary analysis of the STOP-CP (High Sensitivity Cardiac Troponin T to Optimize Chest Pain Risk Stratification) United States (US) multicenter study was to compare the ESC 0/1-hour algorithm for rapid NSTEMI rule-out and 30-day adverse outcomes in patients with and without known CAD. Methods: Patients (≥21 years old) presenting to the (ED) with symptoms suggestive of NSTEMI were enrolled (1/25/2017–9/6/2018) at 8 US medical centers. The ESC hs-cTnT 0/1-hour hs-cTnT algorithm was used to stratify patients into rule-out, observe, and rule-in zones. Algorithm performance for 30-day adverse outcomes was analyzed in patients with or without known CAD. Major adverse cardiovascular events (MACE) consisted of cardiac death, MI, or coronary revascularization. Fisher's exact tests were used to compare NSTEMI rule-out and 30-day MACE rates in patients with and without known CAD.Abstract: Background: The European Society of Cardiology (ESC) 0/1-hour high sensitivity troponin (hs-cTn) algorithm is widely used in the evaluation of patients presenting to the Emergency Department (ED) with symptoms suspicious for non ST-segment elevation myocardial infarction (NSTEMI). There is limited data available for the use of this algorithm comparing NSTEMI rule-out rates and 30-day adverse outcomes in patients with and without known coronary artery disease (CA), defined as prior myocardial infarction [MI], coronary revascularization, or ≥70% coronary stenosis. Purpose: The objective of this secondary analysis of the STOP-CP (High Sensitivity Cardiac Troponin T to Optimize Chest Pain Risk Stratification) United States (US) multicenter study was to compare the ESC 0/1-hour algorithm for rapid NSTEMI rule-out and 30-day adverse outcomes in patients with and without known CAD. Methods: Patients (≥21 years old) presenting to the (ED) with symptoms suggestive of NSTEMI were enrolled (1/25/2017–9/6/2018) at 8 US medical centers. The ESC hs-cTnT 0/1-hour hs-cTnT algorithm was used to stratify patients into rule-out, observe, and rule-in zones. Algorithm performance for 30-day adverse outcomes was analyzed in patients with or without known CAD. Major adverse cardiovascular events (MACE) consisted of cardiac death, MI, or coronary revascularization. Fisher's exact tests were used to compare NSTEMI rule-out and 30-day MACE rates in patients with and without known CAD. Negative likelihood ratios (NLR) with a 95% confidence interval (CI) were calculated for 30-day MACE. Results: Overall 1430 patients were enrolled. Of these 31.4% (449/1430) had known CAD while 14.2% (203 /1430) experienced 30-day MACE. Using the ESC 0/1-hour hs-cTnT algorithm 39.6% (178/449) of patients with known CAD were placed in the rule-out zone compared to 66.1% (648/981) without CAD (p<0.0001). Of patients with known CAD 23.2% (104/449) had 30-day MACE compared to 10.1% (99/981) of those without known CAD (p<0.0001). Additionally, amongst those patients placed in the rule-out zone, 30-day MACE occurred in 7.9% (14/178) of individuals with known CAD and 1.4% (9/648) of those without known CAD (p<0.0001). NLR for 30-day MACE was 0.28 (95% CI 0.17–0.47) in patients with known CAD and 0.13 (95% CI 0.07–0.23) in those without CAD. Conclusions: In the multicenter US STOP-CP study patients with known CAD were less often rapidly ruled out for NSTEMI and had higher 30-day MACE rates than those without known CAD. Patients with known CAD who were rapidly ruled out for NSTEMI had a higher 30-day MACE rate compared to those without known CAD. Our analysis suggests that patients with known CAD require further cardiac reevaluations whether they are ruled out for NSTEMI by the ESC 0/1 hour hs-cTnT algorithm or not. Funding Acknowledgement: Type of funding sources: Private company. Main funding source(s): Roche, Basel, Switzerland … (more)
- Is Part Of:
- European heart journal. Volume 43(2022)Supplement 2
- Journal:
- European heart journal
- Issue:
- Volume 43(2022)Supplement 2
- Issue Display:
- Volume 43, Issue 2 (2022)
- Year:
- 2022
- Volume:
- 43
- Issue:
- 2
- Issue Sort Value:
- 2022-0043-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-10-03
- Subjects:
- Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/eurheartj/ehac544.1337 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24496.xml