Hot or Cold? Is Monothermal Caloric Testing Useful and Cost-Effective?. (June 2013)
- Record Type:
- Journal Article
- Title:
- Hot or Cold? Is Monothermal Caloric Testing Useful and Cost-Effective?. (June 2013)
- Main Title:
- Hot or Cold? Is Monothermal Caloric Testing Useful and Cost-Effective?
- Authors:
- Bush, Matthew L.
Bingcang, Christopher M.
Chang, Edward T.
Fornwalt, Brandon
Rayle, Christopher
Gal, Thomas J.
Jones, Raleigh O.
Shinn, Jennifer B. - Abstract:
- Objectives: Videonystagmography (VNG) is used widely in the assessment of balance dysfunction. The full test battery can be time-consuming and can induce patient discomfort. The purpose of this study was to examine the value of monothermal caloric testing in predicting unilateral caloric weakness, as well as abnormal VNG vestibular and nonvestibular eye movement, while considering the time and reimbursement associated with these tests. Methods: In a retrospective review of 645 patients who completed a comprehensive VNG test battery with bithermal caloric testing, we calculated the specificity, sensitivity, and predictive values of monothermal caloric testing in relation to bithermal caloric results and noncaloric VNG results. Results: With unilateral vestibular weakness (UVW) defined as a 25% interear difference, warm-air monothermal caloric testing yielded a sensitivity of 87% and a negative predictive value of 90% for predicting UVW. With a 10% UVW definition, the warm-air caloric testing sensitivity increased to 95% and the negative predictive value to 92%. Warm-air monothermal caloric testing had a positive predictive value of 85% and a negative predictive value of 18% for predicting noncaloric VNG findings; cold-air monothermal and bithermal testing displayed similar results. Conclusions: Isolated monothermal testing is a sensitive screening tool for detecting UVW, but is not adequate for predicting noncaloric VNG results.
- Is Part Of:
- Annals of otology, rhinology & laryngology. Volume 122:Number 6(2013)
- Journal:
- Annals of otology, rhinology & laryngology
- Issue:
- Volume 122:Number 6(2013)
- Issue Display:
- Volume 122, Issue 6 (2013)
- Year:
- 2013
- Volume:
- 122
- Issue:
- 6
- Issue Sort Value:
- 2013-0122-0006-0000
- Page Start:
- 412
- Page End:
- 416
- Publication Date:
- 2013-06
- Subjects:
- cost-effectiveness -- electronystagmography -- monothermal caloric testing -- videonystagmography
Otolaryngology -- Periodicals
617.51 - Journal URLs:
- http://aor.sagepub.com/ ↗
http://www.sagepublications.com/ ↗
http://www.Annals.com/ ↗ - DOI:
- 10.1177/000348941312200611 ↗
- Languages:
- English
- ISSNs:
- 0003-4894
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 24499.xml