Incidence and predictors of permanent pacemaker implantation following treatment with the repositionable Lotus™ transcatheter aortic valve. Issue 1 (12th November 2016)
- Record Type:
- Journal Article
- Title:
- Incidence and predictors of permanent pacemaker implantation following treatment with the repositionable Lotus™ transcatheter aortic valve. Issue 1 (12th November 2016)
- Main Title:
- Incidence and predictors of permanent pacemaker implantation following treatment with the repositionable Lotus™ transcatheter aortic valve
- Authors:
- Zaman, Sarah
McCormick, Liam
Gooley, Robert
Rashid, Hashrul
Ramkumar, Satish
Jackson, Damon
Hui, Samuel
Meredith, Ian T. - Abstract:
- Abstract : Objectives: To determine the incidence and predictors of permanent pacemaker (PPM) requirement following transcatheter aortic valve replacement (TAVR) with the mechanically expanded Lotus TM Valve System (Boston Scientific). Background: Pacemaker implantation is the most common complication following TAVR. Predictors of pacing following TAVR with the Lotus valve have not been systematically assessed. Methods: Consecutive patients with severe aortic stenosis who underwent Lotus valve implantation were prospectively recruited at a single‐centre. Patients with a pre‐existing PPM were excluded. Baseline ECG, echocardiographic and multiple detector computed tomography as well as procedural telemetry and depth of implantation were independently analyzed in a blinded manner. The primary endpoint was 30‐day incidence of pacemaker requirement (PPM implantation or death while pacing‐dependent). Multivariate analysis was performed to identify independent predictors of the primary endpoint. Results: A total of 104 consecutive patients underwent TAVR with the Lotus valve with 9/104 (9%) with a pre‐existing PPM excluded. New or worsened procedural LBBB occurred in 78%. Thirty‐day incidence of the primary pacing endpoint was 28%. The most common indication for PPM implantation was complete heart block (CHB) (69%). Independent predictors of the primary endpoint included pre‐existing RBBB (hazard ratio [HR] 2.8, 95% CI 1.1–7.0; P = 0.032) and depth of implantation below theAbstract : Objectives: To determine the incidence and predictors of permanent pacemaker (PPM) requirement following transcatheter aortic valve replacement (TAVR) with the mechanically expanded Lotus TM Valve System (Boston Scientific). Background: Pacemaker implantation is the most common complication following TAVR. Predictors of pacing following TAVR with the Lotus valve have not been systematically assessed. Methods: Consecutive patients with severe aortic stenosis who underwent Lotus valve implantation were prospectively recruited at a single‐centre. Patients with a pre‐existing PPM were excluded. Baseline ECG, echocardiographic and multiple detector computed tomography as well as procedural telemetry and depth of implantation were independently analyzed in a blinded manner. The primary endpoint was 30‐day incidence of pacemaker requirement (PPM implantation or death while pacing‐dependent). Multivariate analysis was performed to identify independent predictors of the primary endpoint. Results: A total of 104 consecutive patients underwent TAVR with the Lotus valve with 9/104 (9%) with a pre‐existing PPM excluded. New or worsened procedural LBBB occurred in 78%. Thirty‐day incidence of the primary pacing endpoint was 28%. The most common indication for PPM implantation was complete heart block (CHB) (69%). Independent predictors of the primary endpoint included pre‐existing RBBB (hazard ratio [HR] 2.8, 95% CI 1.1–7.0; P = 0.032) and depth of implantation below the noncoronary cusp (NCC) (HR 2.4, 95% CI 1.0–5.7; P = 0.045). Conclusions: Almost a third of Lotus valve recipients require pacemaker implantation within 30 days. The presence of pre‐existing RBBB and the depth of prosthesis implantation below the NCC were significant pacing predictors. © 2016 Wiley Periodicals, Inc. … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 90:Issue 1(2017)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 90:Issue 1(2017)
- Issue Display:
- Volume 90, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 90
- Issue:
- 1
- Issue Sort Value:
- 2017-0090-0001-0000
- Page Start:
- 147
- Page End:
- 154
- Publication Date:
- 2016-11-12
- Subjects:
- aortic valve disease -- percutaneous intervention -- transcatheter valve implantation -- imaging -- electron beam CT/multidetector CT
Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.26857 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 24488.xml