Fabrication of a strain sensor based on polymer/silver nanowires nanocomposite for medical applications: Siloxane based versus urethane based nanocomposites. Issue 3 (24th December 2020)
- Record Type:
- Journal Article
- Title:
- Fabrication of a strain sensor based on polymer/silver nanowires nanocomposite for medical applications: Siloxane based versus urethane based nanocomposites. Issue 3 (24th December 2020)
- Main Title:
- Fabrication of a strain sensor based on polymer/silver nanowires nanocomposite for medical applications: Siloxane based versus urethane based nanocomposites
- Authors:
- Hashemi, Pegah
Mehranpour, Milad
Ghasemi, Ismail - Abstract:
- Abstract: In the current study, strain sensors based on two polymer matrixes of polydimethylsiloxane (PDMS) and thermoplastic polyurethane (TPU) and conductive nanomaterials of the silver nanowires (AgNWs) were fabricated. The sensors were arranged with a sandwich like morphology in which AgNWs layer(s) were embedded with polymeric layers of PDMS or TPU. The effect of the polymer matrix type and the number of the conductive layers on sensor properties has been evaluated. Morphology and electromechanical properties of the sensors including electrical resistance (R), sensitivity of the resistance change to strain, linearity of the resistance change with strain and repeatability of the sensor response to cyclic loading were analyzed. The experimental results corroborated that with increasing conductive layers from one to three, the resistance decreased by 53% and 61% in respective PDMS and TPU based sensors. Moreover, the sensitivity decreased by 78% and 77% in PDMS and TPU based sensors, respectively. The calculation of the relative SD (RSD) of the maximum ΔR/R0 values substantiated that sensors were able to represent a repeatable response to the sequential loading/unloading cycles. The repeatability was decreased with increasing conductive layers from one to two, and then augmented with further increase in conductive layers. With respect to polymer type, the resistance and repeatability of the TPU based sensors was higher than the PDMS counterparts, whereas the sensitivity ofAbstract: In the current study, strain sensors based on two polymer matrixes of polydimethylsiloxane (PDMS) and thermoplastic polyurethane (TPU) and conductive nanomaterials of the silver nanowires (AgNWs) were fabricated. The sensors were arranged with a sandwich like morphology in which AgNWs layer(s) were embedded with polymeric layers of PDMS or TPU. The effect of the polymer matrix type and the number of the conductive layers on sensor properties has been evaluated. Morphology and electromechanical properties of the sensors including electrical resistance (R), sensitivity of the resistance change to strain, linearity of the resistance change with strain and repeatability of the sensor response to cyclic loading were analyzed. The experimental results corroborated that with increasing conductive layers from one to three, the resistance decreased by 53% and 61% in respective PDMS and TPU based sensors. Moreover, the sensitivity decreased by 78% and 77% in PDMS and TPU based sensors, respectively. The calculation of the relative SD (RSD) of the maximum ΔR/R0 values substantiated that sensors were able to represent a repeatable response to the sequential loading/unloading cycles. The repeatability was decreased with increasing conductive layers from one to two, and then augmented with further increase in conductive layers. With respect to polymer type, the resistance and repeatability of the TPU based sensors was higher than the PDMS counterparts, whereas the sensitivity of the TPU based sensors was lower than the PDMS ones. … (more)
- Is Part Of:
- Polymer composites. Volume 42:Issue 3(2021)
- Journal:
- Polymer composites
- Issue:
- Volume 42:Issue 3(2021)
- Issue Display:
- Volume 42, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 42
- Issue:
- 3
- Issue Sort Value:
- 2021-0042-0003-0000
- Page Start:
- 1440
- Page End:
- 1450
- Publication Date:
- 2020-12-24
- Subjects:
- nanocomposites -- polysiloxanes -- polyurethane -- sensor
Polymeric composites -- Periodicals
620.192 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1548-0569 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/pc.25914 ↗
- Languages:
- English
- ISSNs:
- 0272-8397
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6547.704300
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24486.xml