Dosimetric comparison of VitalBeam® and HalcyonTM 2.0 for hypofractionated VMAT with simultaneous integrated boost treatment of early‐stage left‐sided breast cancer. Issue 10 (23rd September 2021)
- Record Type:
- Journal Article
- Title:
- Dosimetric comparison of VitalBeam® and HalcyonTM 2.0 for hypofractionated VMAT with simultaneous integrated boost treatment of early‐stage left‐sided breast cancer. Issue 10 (23rd September 2021)
- Main Title:
- Dosimetric comparison of VitalBeam® and HalcyonTM 2.0 for hypofractionated VMAT with simultaneous integrated boost treatment of early‐stage left‐sided breast cancer
- Authors:
- Ju, Eunbin
Heo, Eun Jeong
Park, Chun Gun
Kim, Minseok
Kim, Kwang Hyeon
Shim, Jang Bo
Park, Young Je
Lee, Nam Kwon
Kim, Chul Yong
Lee, Suk - Abstract:
- Abstract: Purpose: This study compared the quality of treatment plans for early‐stage, left‐sided breast cancer, as planned for and delivered by the Halcyon TM and VitalBeam ® . Materials and methods: Fifteen patients diagnosed with early‐stage left‐sided breast cancer, who had received VMAT with hypofractionated SIB, were recruited. All cases were planned using Halcyon TM comprising a dual‐layer MLC (DL‐MLC) and VitalBeam ® with a Millennium 120 MLC (VB‐MLC). For the PTVs, the quality of coverage (QC), conformity index (CI), and homogeneity index (HI) were calculated for each plan. The dosimetric differences between the two treatment plans were statistically compared using the Wilcoxon signed‐rank test ( p < 0.05). To evaluate delivery efficiency, the average delivery time for each patient's treatment plan was recorded and compared. Results: For the PTVs, the two plans (DL‐MLC and VB‐MLC) were comparable in terms of the QC, CI, and HI. However, V 30Gy and D mean for the heart in the DL‐MLC plan were significantly reduced by 0.49% and 14.6%, respectively, compared with those in the VB‐MLC plan ( p < 0.05). The D mean value for the ipsilateral lung in the DL‐MLC plan significantly decreased by 5.5%, compared with that in the VB‐MLC plan ( p < 0.05). In addition, the delivery times for the DL‐MLC and VB‐MLC plans were 79 ± 10 and 101 ± 11 s, respectively. Conclusions: DL‐MLC plans were found to improve OAR sparing. In particular, when treating left‐sided breast cancer viaAbstract: Purpose: This study compared the quality of treatment plans for early‐stage, left‐sided breast cancer, as planned for and delivered by the Halcyon TM and VitalBeam ® . Materials and methods: Fifteen patients diagnosed with early‐stage left‐sided breast cancer, who had received VMAT with hypofractionated SIB, were recruited. All cases were planned using Halcyon TM comprising a dual‐layer MLC (DL‐MLC) and VitalBeam ® with a Millennium 120 MLC (VB‐MLC). For the PTVs, the quality of coverage (QC), conformity index (CI), and homogeneity index (HI) were calculated for each plan. The dosimetric differences between the two treatment plans were statistically compared using the Wilcoxon signed‐rank test ( p < 0.05). To evaluate delivery efficiency, the average delivery time for each patient's treatment plan was recorded and compared. Results: For the PTVs, the two plans (DL‐MLC and VB‐MLC) were comparable in terms of the QC, CI, and HI. However, V 30Gy and D mean for the heart in the DL‐MLC plan were significantly reduced by 0.49% and 14.6%, respectively, compared with those in the VB‐MLC plan ( p < 0.05). The D mean value for the ipsilateral lung in the DL‐MLC plan significantly decreased by 5.5%, compared with that in the VB‐MLC plan ( p < 0.05). In addition, the delivery times for the DL‐MLC and VB‐MLC plans were 79 ± 10 and 101 ± 11 s, respectively. Conclusions: DL‐MLC plans were found to improve OAR sparing. In particular, when treating left‐sided breast cancer via DL‐MLC plans, the risk of heart toxicity is expected to be reduced. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 22:Issue 10(2021)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 22:Issue 10(2021)
- Issue Display:
- Volume 22, Issue 10 (2021)
- Year:
- 2021
- Volume:
- 22
- Issue:
- 10
- Issue Sort Value:
- 2021-0022-0010-0000
- Page Start:
- 232
- Page End:
- 238
- Publication Date:
- 2021-09-23
- Subjects:
- dosimetric comparison -- HalcyonTM -- left‐sided breast cancer -- VitalBeam®
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.13428 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24477.xml