Utility of transesophageal echocardiography to assess real time left atrial pressure changes and dynamic mitral regurgitation following placement of transseptal multistage venous cannula for systemic venous drainage and indirect left ventricular venting in venoarterial extracorporeal membrane oxygenation. Issue 3 (22nd February 2021)
- Record Type:
- Journal Article
- Title:
- Utility of transesophageal echocardiography to assess real time left atrial pressure changes and dynamic mitral regurgitation following placement of transseptal multistage venous cannula for systemic venous drainage and indirect left ventricular venting in venoarterial extracorporeal membrane oxygenation. Issue 3 (22nd February 2021)
- Main Title:
- Utility of transesophageal echocardiography to assess real time left atrial pressure changes and dynamic mitral regurgitation following placement of transseptal multistage venous cannula for systemic venous drainage and indirect left ventricular venting in venoarterial extracorporeal membrane oxygenation
- Authors:
- Meers, Jacob Bradley
Nanda, Navin C.
Watts, Thomas Evan
Prejean, Shane
Hoopes, Charles W.
Lenneman, Andrew
Ahmed, Mustafa I. - Abstract:
- Abstract: A patient with heart failure due to nonischemic cardiomyopathy presented as a transfer to our institution following peripheral (femoral) venoarterial (VA) extracorporeal membrane oxygenation (ECMO) placement. With peripheral VA ECMO cannulation, the patient continued to have unstable ventricular tachyarrhythmias. Echocardiography demonstrated left ventricular (LV) dilation and severe mitral regurgitation (MR) with clinical and chest X‐ray evidence of pulmonary edema. To provide venous drainage and simultaneous decompression of the left atrium (LA) and thereby indirect LV venting, a single multistage venous cannula was placed across the inter‐atrial septum (IAS) using the previously described left atrial venoarterial (LA‐VA) ECMO cannulation technique. Two‐ and three‐dimensional (3D) transesophageal echocardiography (TEE) demonstrated utility in guiding cannula placement into the appropriate position and providing real time assessment of ventricular decompression and MR severity. There was subsequent improvement in pulmonary edema. This case is thought to be the first demonstration of real time resolution of pulmonary venous flow reversal in a patient undergoing LA‐VA ECMO cannulation. This demonstration offers important mechanistic insight into some of the potential benefits of such an approach.
- Is Part Of:
- Echocardiography. Volume 38:Issue 3(2021)
- Journal:
- Echocardiography
- Issue:
- Volume 38:Issue 3(2021)
- Issue Display:
- Volume 38, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 38
- Issue:
- 3
- Issue Sort Value:
- 2021-0038-0003-0000
- Page Start:
- 493
- Page End:
- 499
- Publication Date:
- 2021-02-22
- Subjects:
- ECMO -- extracorporeal membranous oxygenation -- left atrial pressure -- mechanical circulatory support -- mitral regurgitation -- three‐dimensional echocardiography -- transseptal cannulation
Echocardiography -- Periodicals
Echocardiography -- Periodicals
616.1207543 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8175 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/echo.14990 ↗
- Languages:
- English
- ISSNs:
- 0742-2822
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3647.572500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 24479.xml