Effect of CAD/CAM aesthetic material thickness and translucency on the polymerisation of light- and dual-cured resin cements. Issue 12 (December 2022)
- Record Type:
- Journal Article
- Title:
- Effect of CAD/CAM aesthetic material thickness and translucency on the polymerisation of light- and dual-cured resin cements. Issue 12 (December 2022)
- Main Title:
- Effect of CAD/CAM aesthetic material thickness and translucency on the polymerisation of light- and dual-cured resin cements
- Authors:
- Babaier, Rua
Haider, Julfikar
Silikas, Nick
Watts, David C. - Abstract:
- Abstract: Objectives: This study investigated potential variations in polymerisation of light- and dual-cured (LC and DC) resin cements photoactivated through four CAD/CAM restorative materials as a function of substrate thickness. Methods: Four CAD/CAM materials [two resin composites CeraSmart (CS) and Grandio Blocs (GB); a polymer infiltrated ceramic Vita Enamic (VE) and a feldspathic ceramic Vita Mark II (VM)], with five thicknesses (0.5, 1, 1.5, 2, and 2.5 mm) were prepared and their optical characteristics measured. 1 mm discs of LC and DC resin cement (Variolink® Esthetic, Ivoclar AG) were photoactivated through each specimen thickness. After 1 h post-cure, polymerisation efficiency was determined by degree of conversion (DC%) and Martens hardness (HM ). Interactions between materials, thicknesses and properties were analysed by linear regressions, two-way ANOVA and one-way ANOVA followed by post hoc multiple comparisons (α = 0.05). Results: All substrates of 0.5- and 1.0-mm thickness transmitted sufficiently high peak irradiances at around 455 nm: (It = 588–819 mW/cm 2 ) with translucency parameter TP = 21.14 – 10.7; ranked: CS> GB = VM> VE. However, increasing the substrate thickness (1.5–2.5 mm) reduced energy delivery to the luting cements (4 – 2.8 J/cm 2 ). Consequently, as their thicknesses increased beyond 1.5 mm, HM of the cement discs differed significantly between the substrates. But there were only slight reduction of DC% in LC cements and DC cement discsAbstract: Objectives: This study investigated potential variations in polymerisation of light- and dual-cured (LC and DC) resin cements photoactivated through four CAD/CAM restorative materials as a function of substrate thickness. Methods: Four CAD/CAM materials [two resin composites CeraSmart (CS) and Grandio Blocs (GB); a polymer infiltrated ceramic Vita Enamic (VE) and a feldspathic ceramic Vita Mark II (VM)], with five thicknesses (0.5, 1, 1.5, 2, and 2.5 mm) were prepared and their optical characteristics measured. 1 mm discs of LC and DC resin cement (Variolink® Esthetic, Ivoclar AG) were photoactivated through each specimen thickness. After 1 h post-cure, polymerisation efficiency was determined by degree of conversion (DC%) and Martens hardness (HM ). Interactions between materials, thicknesses and properties were analysed by linear regressions, two-way ANOVA and one-way ANOVA followed by post hoc multiple comparisons (α = 0.05). Results: All substrates of 0.5- and 1.0-mm thickness transmitted sufficiently high peak irradiances at around 455 nm: (It = 588–819 mW/cm 2 ) with translucency parameter TP = 21.14 – 10.7; ranked: CS> GB = VM> VE. However, increasing the substrate thickness (1.5–2.5 mm) reduced energy delivery to the luting cements (4 – 2.8 J/cm 2 ). Consequently, as their thicknesses increased beyond 1.5 mm, HM of the cement discs differed significantly between the substrates. But there were only slight reduction of DC% in LC cements and DC cement discs were not affected. Significance: Photoactivating light-cured Ivocerin™ containing cement through feldspathic ceramics and polymer-infiltrated ceramics achieved greater early hardness results than dual-cured type, irrespective of substrate thickness (0.5 – 2.5 mm). However, only 0.5 and 1 mm-thick resin composites showed similar outcome (LC>DC). Therefore, for cases requiring early hardness development, appropriate cement selection for each substrate material is recommended. … (more)
- Is Part Of:
- Dental materials. Volume 38:Issue 12(2022)
- Journal:
- Dental materials
- Issue:
- Volume 38:Issue 12(2022)
- Issue Display:
- Volume 38, Issue 12 (2022)
- Year:
- 2022
- Volume:
- 38
- Issue:
- 12
- Issue Sort Value:
- 2022-0038-0012-0000
- Page Start:
- 2073
- Page End:
- 2083
- Publication Date:
- 2022-12
- Subjects:
- CAD/CAM -- Resin cements -- Optical properties -- Translucency -- Irradiance -- Radiant exposure -- FTIR -- Degree of conversion -- Martens hardness
Dentistry -- Periodicals
Dental materials -- Periodicals
617.695 - Journal URLs:
- http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science/journal/01095641/ ↗ - DOI:
- 10.1016/j.dental.2022.11.016 ↗
- Languages:
- English
- ISSNs:
- 0109-5641
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3553.365800
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 24462.xml