Analysis of sex steroids in human tears using LC-MS and GC-MS: Considerations and developments to improve method sensitivity and accuracy. (December 2022)
- Record Type:
- Journal Article
- Title:
- Analysis of sex steroids in human tears using LC-MS and GC-MS: Considerations and developments to improve method sensitivity and accuracy. (December 2022)
- Main Title:
- Analysis of sex steroids in human tears using LC-MS and GC-MS: Considerations and developments to improve method sensitivity and accuracy
- Authors:
- Phan, Minh Anh Thu
Gibson, Emma
Golebiowski, Blanka
Stapleton, Fiona
Jenner, Andrew M.
Bucknall, Martin P. - Abstract:
- Abstract: Sex steroids play a role in regulation of tear film function and may exert their action locally at the ocular surface. However, measurement of sex steroids in tears is difficult due to small-volume tear samples and very low concentrations of the hormones. This short communication highlights what has been achieved to date in the analysis of tear sex steroids using ultra-performance LC-MS (UPLC-MS) as previously published, and reports further and more recent investigations toward optimising mass spectrometry method sensitivity and accuracy. The published UPLC-MS method successfully measured progesterone, androsterone glucuronide and 5α-androstane-3α, 17β-diol in pooled basal tears of postmenopausal women, and fourteen sex steroid standards in methanol. Limitations included sub-optimal limits of detection (LOD) and lower limits of quantification (LLOQ) for some analytes (particularly oestrogens), exclusion of sample matrix effects and no use of internal standards. This update reports on further experiments carried out to improve sensitivity and accuracy. Sample matrix effects, internal standard spiking, and derivatisation with dansyl chloride and oximes were investigated. Dansylation significantly improved the LOD and LLOQ of oestrogens and their metabolites, by a factor of 10 for oestradiol and a factor of 5 for oestrone, but sensitivity of this updated method is not sufficient however for analysis of these oestrogens in human tears. Using gas chromatography-massAbstract: Sex steroids play a role in regulation of tear film function and may exert their action locally at the ocular surface. However, measurement of sex steroids in tears is difficult due to small-volume tear samples and very low concentrations of the hormones. This short communication highlights what has been achieved to date in the analysis of tear sex steroids using ultra-performance LC-MS (UPLC-MS) as previously published, and reports further and more recent investigations toward optimising mass spectrometry method sensitivity and accuracy. The published UPLC-MS method successfully measured progesterone, androsterone glucuronide and 5α-androstane-3α, 17β-diol in pooled basal tears of postmenopausal women, and fourteen sex steroid standards in methanol. Limitations included sub-optimal limits of detection (LOD) and lower limits of quantification (LLOQ) for some analytes (particularly oestrogens), exclusion of sample matrix effects and no use of internal standards. This update reports on further experiments carried out to improve sensitivity and accuracy. Sample matrix effects, internal standard spiking, and derivatisation with dansyl chloride and oximes were investigated. Dansylation significantly improved the LOD and LLOQ of oestrogens and their metabolites, by a factor of 10 for oestradiol and a factor of 5 for oestrone, but sensitivity of this updated method is not sufficient however for analysis of these oestrogens in human tears. Using gas chromatography-mass spectrometry (GC-MS) as an alternative technique to LC-MS, improved sensitivity for derivatised oestradiol is reported. This work demonstrates the need to develop higher sensitivity methods and points researchers towards specific MS ionisation techniques for future analysis of sex steroids in tears, in order to progress current understanding of the role of sex steroids in tear function and dry eye. Highlights: Analysis of sex steroids in tears is challenging due to the extremely limited sample volumes and low analyte concentrations. UPLC-MS performed on a Orbitrap MS in APCI+ mode with dansyl chloride derivatisation improved sensitivity for oestrogens. UPLC-MS plus derivatisation was more suitable than GC-MS for analysing sex steroids in tears. … (more)
- Is Part Of:
- Experimental eye research. Volume 225(2022)
- Journal:
- Experimental eye research
- Issue:
- Volume 225(2022)
- Issue Display:
- Volume 225, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 225
- Issue:
- 2022
- Issue Sort Value:
- 2022-0225-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-12
- Subjects:
- Sex steroids -- LC-MS -- GC-MS -- Tear film -- Serum
Ophthalmology -- Periodicals
Eye -- Periodicals
Œil -- Périodiques
Ophthalmology
Periodicals
Electronic journals
612.8405 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00144835 ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0014-4835;screen=info;ECOIP ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.exer.2022.109283 ↗
- Languages:
- English
- ISSNs:
- 0014-4835
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3839.150000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24469.xml