Correspondence between scapular anatomical coordinate systems and the 3D axis of motion: A new perspective on an old challenge. (December 2022)
- Record Type:
- Journal Article
- Title:
- Correspondence between scapular anatomical coordinate systems and the 3D axis of motion: A new perspective on an old challenge. (December 2022)
- Main Title:
- Correspondence between scapular anatomical coordinate systems and the 3D axis of motion: A new perspective on an old challenge
- Authors:
- Lawrence, Rebekah L.
Roseni, Kevin
Bey, Michael J. - Abstract:
- Abstract: Several scapular anatomical coordinate systems have been reported in the literature to describe shoulder kinematics. Unfortunately, the use of different conventions hinders comparison across studies. Further, inconsistencies between a coordinate system and the scapula's 3D axis of motion means that scapular motion will be incorrectly attributed to axes about which it did not rotate. The objectives of this study were to: 1) determine the extent to which the axes of four common scapular coordinate system conventions correspond to the 3D axis of scapular motion (i.e., instantaneous helical axis, IHA), and 2) report the prevalence of scapulothoracic gimbal lock for each convention. Shoulder kinematics were tracked during scapular plane abduction in 45 participants using biplane videoradiography. Scapulothoracic kinematics were described using the original convention proposed by van der Helm, the convention recommended by the International Society of Biomechanics (ISB), a glenoid-based coordinate system, and a glenoid-oriented coordinate system. The 3D angle was calculated between the IHA and each axis of the four conventions (IHA-axis angular deviations). A repeated measures ANOVA was used to compare IHA-axis angular deviations between conventions. The glenoid-oriented and ISB conventions resulted in the smallest and largest IHA-axis angular deviations, respectively (21.7°±3.6° vs. 30.5°±5.2°, p < 0.01). Gimbal lock was approached in 17.8% of participants when usingAbstract: Several scapular anatomical coordinate systems have been reported in the literature to describe shoulder kinematics. Unfortunately, the use of different conventions hinders comparison across studies. Further, inconsistencies between a coordinate system and the scapula's 3D axis of motion means that scapular motion will be incorrectly attributed to axes about which it did not rotate. The objectives of this study were to: 1) determine the extent to which the axes of four common scapular coordinate system conventions correspond to the 3D axis of scapular motion (i.e., instantaneous helical axis, IHA), and 2) report the prevalence of scapulothoracic gimbal lock for each convention. Shoulder kinematics were tracked during scapular plane abduction in 45 participants using biplane videoradiography. Scapulothoracic kinematics were described using the original convention proposed by van der Helm, the convention recommended by the International Society of Biomechanics (ISB), a glenoid-based coordinate system, and a glenoid-oriented coordinate system. The 3D angle was calculated between the IHA and each axis of the four conventions (IHA-axis angular deviations). A repeated measures ANOVA was used to compare IHA-axis angular deviations between conventions. The glenoid-oriented and ISB conventions resulted in the smallest and largest IHA-axis angular deviations, respectively (21.7°±3.6° vs. 30.5°±5.2°, p < 0.01). Gimbal lock was approached in 17.8% of participants when using the original convention, 2.2% when using the ISB convention, and 0% when using the glenoid-based or -oriented conventions. These findings suggest the glenoid-oriented coordinate system may be worthy of further consideration when investigating shoulder kinematics during scapular plane abduction. … (more)
- Is Part Of:
- Journal of biomechanics. Volume 145(2022)
- Journal:
- Journal of biomechanics
- Issue:
- Volume 145(2022)
- Issue Display:
- Volume 145, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 145
- Issue:
- 2022
- Issue Sort Value:
- 2022-0145-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-12
- Subjects:
- Kinematics -- Scapula -- Anatomical coordinate systems -- Gimbal lock
Animal mechanics -- Periodicals
Biomechanics -- Periodicals
Biomechanics -- Periodicals
Mécanique animale -- Périodiques
Biomécanique -- Périodiques
Electronic journals
571.4305 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00219290 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00219290 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219290 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jbiomech.2022.111385 ↗
- Languages:
- English
- ISSNs:
- 0021-9290
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.600000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24452.xml