Characterization of helium retention in the inhomogeneous co-deposited layers using a long pulse laser induced ablation-quadrupole mass spectroscopy. (October 2022)
- Record Type:
- Journal Article
- Title:
- Characterization of helium retention in the inhomogeneous co-deposited layers using a long pulse laser induced ablation-quadrupole mass spectroscopy. (October 2022)
- Main Title:
- Characterization of helium retention in the inhomogeneous co-deposited layers using a long pulse laser induced ablation-quadrupole mass spectroscopy
- Authors:
- Lyu, Yan
He, Zhonglin
Wang, XueYan
Bai, Xue
Li, Cong
Wu, Ding
Hai, Ran
Ding, Hongbin - Abstract:
- Highlights: The 2D-resolved quantitative characterization of the He retention in the inhomogeneous co-deposited layers has been carried out using 750 microsecond pulse laser induced ablation-quadrupole mass spectrometry (LIA-QMS). The concentration of He atoms in the co-deposited layer has been determined based on the measured He mass spectral intensity and the ablation mass of laser ablated crater. LIA-QMS approach has a significantly potential for the 2D-resolved quantitative diagnosis for the He or D/T retention in the non-uniform co-deposited layers on PFMs in nuclear fusion devices. Abstract: In this work, a spatially lateral-resolved study of the co-deposition of helium (He) and aluminum (Al) in non-uniform layers is carried out by a long pulse Laser-Induced Ablation-Quadrupole Mass Spectrometry (LIA-QMS) approach. He was co-deposited with Al on the silicon (Si) substrate by Pulse Laser Deposition (PLD) method at He ambient pressure of 4.0 Pa. The Al is a proxy of beryllium (Be) because the Be is toxic. The thickness of the He-Al co-deposited layers decreases from approximately 3.9 µm to 0.2 µm with increasing lateral distance measured using white light confocal 3-D profilometer. The areal number density of He-retention in the inhomogeneous co-deposited layers decreases from 5.8 × 10 21 to 7.5 × 10 19 He/m 2 along the lateral distance, which is consistent with the variation trend of the deposition layer thickness. The 2-D imaging of the He atomic areal density measuredHighlights: The 2D-resolved quantitative characterization of the He retention in the inhomogeneous co-deposited layers has been carried out using 750 microsecond pulse laser induced ablation-quadrupole mass spectrometry (LIA-QMS). The concentration of He atoms in the co-deposited layer has been determined based on the measured He mass spectral intensity and the ablation mass of laser ablated crater. LIA-QMS approach has a significantly potential for the 2D-resolved quantitative diagnosis for the He or D/T retention in the non-uniform co-deposited layers on PFMs in nuclear fusion devices. Abstract: In this work, a spatially lateral-resolved study of the co-deposition of helium (He) and aluminum (Al) in non-uniform layers is carried out by a long pulse Laser-Induced Ablation-Quadrupole Mass Spectrometry (LIA-QMS) approach. He was co-deposited with Al on the silicon (Si) substrate by Pulse Laser Deposition (PLD) method at He ambient pressure of 4.0 Pa. The Al is a proxy of beryllium (Be) because the Be is toxic. The thickness of the He-Al co-deposited layers decreases from approximately 3.9 µm to 0.2 µm with increasing lateral distance measured using white light confocal 3-D profilometer. The areal number density of He-retention in the inhomogeneous co-deposited layers decreases from 5.8 × 10 21 to 7.5 × 10 19 He/m 2 along the lateral distance, which is consistent with the variation trend of the deposition layer thickness. The 2-D imaging of the He atomic areal density measured by LIA-QMS shows that the He-retention in the co-deposition layer is significantly inhomogeneous. The maximum and minimum of the He concentration in atom ratio in the co-deposited layer are about 4 % and 0.4 %, respectively. The results indicate that LIA-QMS diagnostic approach has a significantly potential for the 2D-resolved quantitative characterization of the He (or D/T) retention in the co-deposited layers on Plasma Facing Materials (PFMs). … (more)
- Is Part Of:
- Nuclear materials and energy. Volume 33(2022)
- Journal:
- Nuclear materials and energy
- Issue:
- Volume 33(2022)
- Issue Display:
- Volume 33, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 33
- Issue:
- 2022
- Issue Sort Value:
- 2022-0033-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-10
- Subjects:
- LIA-QMS -- He-retention -- 2D-imaging of He atomic density -- Inhomogeneous co-deposited layer
Nuclear energy -- Periodicals
Nuclear fuels -- Periodicals
Nuclear reactors -- Materials -- Periodicals
Radioactive substances -- Periodicals
621.4833 - Journal URLs:
- http://www.sciencedirect.com/science/journal/23521791 ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.nme.2022.101268 ↗
- Languages:
- English
- ISSNs:
- 2352-1791
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24451.xml