Validation of a novel high-sensitivity cardiac troponin assay. (3rd October 2022)
- Record Type:
- Journal Article
- Title:
- Validation of a novel high-sensitivity cardiac troponin assay. (3rd October 2022)
- Main Title:
- Validation of a novel high-sensitivity cardiac troponin assay
- Authors:
- Restan, I
Steiro, O T
Tjora, H L
Langoergen, J
Omland, T
Collinson, P
Bjoerneklett, R
Vikenes, K
Steinsvik, T
Skadberg, O
Mjelva, O R
Larsen, A I
Bonarjee, V S
Aakre, K M - Abstract:
- Abstract: Background: The accuracy for early identification of non-ST-elevation myocardial infarction (NSTEMI) in the emergency department must be determined for all novel high-sensitivity cardiac troponin assays (hs-cTn). In this prospective, multi-centre study we developed rule-out algorithms for a high-sensitivity cardiac troponin I (hs-cTnI) assay and compared it to established algorithms for hs-cTnT and hs-cTnI. Methods: Two rule-out algorithms for NSTEMI were developed from a derivation cohort of 977 patients assessed by the Siemens Atellica IM hs-cTnI assay. Diagnostic performance was compared with hs-cTnT (Roche) and hs-cTnI (Abbott) algorithms. The derived algorithms were tested in two different validation cohorts (n=518 and n=405, respectively). Results: An admission sample algorithm (hs-cTnI (Siemens)) for rule-out of NSTEMI with cutoff <5 ng/L had negative predictive value (NPV) 99.4–100.0%, sensitivity 98.3–100% and specificity 46.7–56.5% in the two validation cohorts. Sensitivity and NPV was similar, specificity trended towards improvement over the comparator algorithms (Figure 1). A 0–1 hour algorithm (hs-cTnI (Siemens)) with cutoff <10 ng/L and Δ change <3 ng/L achieved sensitivity and NPV 100% with specificity >70% in both validation cohorts, similar to the comparator algorithms (Table 1). Conclusions: Rule-out algorithms from the Siemens Atellica hs-cTnI assay has comparable diagnostic accuracy to established hs-cTn rule-out algorithms. FundingAbstract: Background: The accuracy for early identification of non-ST-elevation myocardial infarction (NSTEMI) in the emergency department must be determined for all novel high-sensitivity cardiac troponin assays (hs-cTn). In this prospective, multi-centre study we developed rule-out algorithms for a high-sensitivity cardiac troponin I (hs-cTnI) assay and compared it to established algorithms for hs-cTnT and hs-cTnI. Methods: Two rule-out algorithms for NSTEMI were developed from a derivation cohort of 977 patients assessed by the Siemens Atellica IM hs-cTnI assay. Diagnostic performance was compared with hs-cTnT (Roche) and hs-cTnI (Abbott) algorithms. The derived algorithms were tested in two different validation cohorts (n=518 and n=405, respectively). Results: An admission sample algorithm (hs-cTnI (Siemens)) for rule-out of NSTEMI with cutoff <5 ng/L had negative predictive value (NPV) 99.4–100.0%, sensitivity 98.3–100% and specificity 46.7–56.5% in the two validation cohorts. Sensitivity and NPV was similar, specificity trended towards improvement over the comparator algorithms (Figure 1). A 0–1 hour algorithm (hs-cTnI (Siemens)) with cutoff <10 ng/L and Δ change <3 ng/L achieved sensitivity and NPV 100% with specificity >70% in both validation cohorts, similar to the comparator algorithms (Table 1). Conclusions: Rule-out algorithms from the Siemens Atellica hs-cTnI assay has comparable diagnostic accuracy to established hs-cTn rule-out algorithms. Funding Acknowledgement: Type of funding sources: Public grant(s) – National budget only. Main funding source(s): Public grant: Western Norway Regional Health Authority.Private company funding: Siemens Healthineers AG … (more)
- Is Part Of:
- European heart journal. Volume 43(2022)Supplement 2
- Journal:
- European heart journal
- Issue:
- Volume 43(2022)Supplement 2
- Issue Display:
- Volume 43, Issue 2 (2022)
- Year:
- 2022
- Volume:
- 43
- Issue:
- 2
- Issue Sort Value:
- 2022-0043-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-10-03
- Subjects:
- Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/eurheartj/ehac544.1363 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24445.xml