Reliability of two dissociating tests of phoria in artificially created phoria in normal adults. Issue 5 (8th September 2021)
- Record Type:
- Journal Article
- Title:
- Reliability of two dissociating tests of phoria in artificially created phoria in normal adults. Issue 5 (8th September 2021)
- Main Title:
- Reliability of two dissociating tests of phoria in artificially created phoria in normal adults
- Authors:
- Helminski, Janet O.
Keller, Sarah
Suckow, Melissa
Stein, Amy
Grieco, Lauren
Lintakas, Rima
Reinders, Caroline - Abstract:
- Abstract: Background: The ability of physical therapists (PTs) to accurately identify and reliably measure phoria/tropia is critical in the differential diagnosis of individuals with acute vestibular syndrome and concussion/mild traumatic brain injury. Objectives: To determine if PTs may reliably measure phoria and to determine the reliability of two dissociating tests of phoria, the prism neutralized Maddox rod test and modified Thorington method, in normal adults with artificially created phoria. Methods: Thirty adults (mean age 24.87 ± 4.74 years) were randomly assigned to wear trial lenses (1, 2, 4, or 6 pd prism left, plain glass right) to create phoria. In sitting and supine, phoria was measured using prism neutralized Maddox rod test and modified Thorington method. Mean, SD, and range of first neutral endpoint were calculated for each examiner. Percentage of trials in agreement (≤ 2 and 4 pd); comparisons within the linear mixed effects regression model; and inter‐rater reliability between examiners was calculated with the intra‐class correlation coefficient (ICC). Results: Participants underwent 20 measurements by each examiner. Trial agreement between examiners was 74% (range 13%‐100%) in horizontal and 91% (range 63%‐100%) in vertical plane. Maddox rod test had significantly different means between two examiners ( P < .05). Modified Thorington test had no significant difference. The Maddox rod test had a significant examiner main effect, examiner 2 always scoredAbstract: Background: The ability of physical therapists (PTs) to accurately identify and reliably measure phoria/tropia is critical in the differential diagnosis of individuals with acute vestibular syndrome and concussion/mild traumatic brain injury. Objectives: To determine if PTs may reliably measure phoria and to determine the reliability of two dissociating tests of phoria, the prism neutralized Maddox rod test and modified Thorington method, in normal adults with artificially created phoria. Methods: Thirty adults (mean age 24.87 ± 4.74 years) were randomly assigned to wear trial lenses (1, 2, 4, or 6 pd prism left, plain glass right) to create phoria. In sitting and supine, phoria was measured using prism neutralized Maddox rod test and modified Thorington method. Mean, SD, and range of first neutral endpoint were calculated for each examiner. Percentage of trials in agreement (≤ 2 and 4 pd); comparisons within the linear mixed effects regression model; and inter‐rater reliability between examiners was calculated with the intra‐class correlation coefficient (ICC). Results: Participants underwent 20 measurements by each examiner. Trial agreement between examiners was 74% (range 13%‐100%) in horizontal and 91% (range 63%‐100%) in vertical plane. Maddox rod test had significantly different means between two examiners ( P < .05). Modified Thorington test had no significant difference. The Maddox rod test had a significant examiner main effect, examiner 2 always scored lower. Inter‐rater correlation coefficient for each test was significant at level of P < .01 (ICC ≥ 0.67 ≤ 0.94) except for modified Thorington test in supine, horizontal plane with P < .05 (ICC ≥ 0.38). Conclusion: PTs may reliably measure artificially created phorias using prism neutralized Maddox rod test and modified Thorington method. Abstract : Physical therapists may reliably measure phoria using the prism neutralized Maddox Rod Test and modified Thorington method in sitting and supine recumbent positions in normal adults with artificially created phoria. These tests may be reliably performed to identify and measure misalignment of the visual axis to assist in the differential diagnosis of individuals with acute vestibular syndrome and management of individuals with concussion/mild traumatic brain injury. … (more)
- Is Part Of:
- Laryngoscope investigative otolaryngology. Volume 6:Issue 5(2021)
- Journal:
- Laryngoscope investigative otolaryngology
- Issue:
- Volume 6:Issue 5(2021)
- Issue Display:
- Volume 6, Issue 5 (2021)
- Year:
- 2021
- Volume:
- 6
- Issue:
- 5
- Issue Sort Value:
- 2021-0006-0005-0000
- Page Start:
- 1142
- Page End:
- 1150
- Publication Date:
- 2021-09-08
- Subjects:
- dissociative test -- ocular misalignment test -- phoria test -- skew deviation -- vertical diplopia
Otolaryngology -- Periodicals
Laryngoscopy -- Periodicals
Otolaryngology
Otolaryngology
Periodicals
Periodicals
617.51 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2378-8038 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/lio2.653 ↗
- Languages:
- English
- ISSNs:
- 2378-8038
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24443.xml