PERFORMANCE 1 study: Novel carotid stent system with integrated post‐dilation balloon and embolic protection device. Issue 6 (13th October 2022)
- Record Type:
- Journal Article
- Title:
- PERFORMANCE 1 study: Novel carotid stent system with integrated post‐dilation balloon and embolic protection device. Issue 6 (13th October 2022)
- Main Title:
- PERFORMANCE 1 study: Novel carotid stent system with integrated post‐dilation balloon and embolic protection device
- Authors:
- Langhoff, Ralf
Petrov, Ivo
Kedev, Sasko
Milosevic, Zoran
Schmidt, Andrej
Scheinert, Dierk
Schofer, Joachim
Sievert, Horst
Sedgewick, Gerald
Saylors, Elizabeth
Sachar, Ravish
Cremonesi, Alberto
Micari, Antonio - Abstract:
- Abstract: Objectives: The PERFORMANCE I study was designed to evaluate the safety and feasibility of the Neuroguard IEP® System, a novel carotid stent system with an integrated embolic filter and post‐dilatation balloon, to treat clinically significant carotid artery stenosis. Background: The risk of major adverse events during carotid artery stenting is comparable to carotid endarterectomy, however, the risk of minor stroke remains higher with stenting. Methods: In total, 67 patients undergoing carotid artery stenting were enrolled at nine centers in Europe. Follow‐up assessments included neurological exams, duplex ultrasound, 12‐lead electrocardiogram, and cardiac enzyme analysis. The primary endpoint was the 30‐day composite rate of stroke, death, and myocardial infarctions versus a prespecified performance goal. Secondary endpoints included procedure success, device success, and target lesion revascularization. Results: The study population was predominantly male (74.6%) with a mean age of 69.3 ± 8.9 years and 67% of subjects met at least one criterion placing them at an elevated risk for adverse events following carotid endarterectomy. All patients were treated successfully with the study device. There were no deaths or strokes within 30 days of the index procedure. One subject (1.5%) experienced a non‐ST elevation myocardial infarction at day 17. The primary endpoint was met with a 30‐day major adverse events rate of 1.5% (1/67). Through 12‐month follow‐up, there wereAbstract: Objectives: The PERFORMANCE I study was designed to evaluate the safety and feasibility of the Neuroguard IEP® System, a novel carotid stent system with an integrated embolic filter and post‐dilatation balloon, to treat clinically significant carotid artery stenosis. Background: The risk of major adverse events during carotid artery stenting is comparable to carotid endarterectomy, however, the risk of minor stroke remains higher with stenting. Methods: In total, 67 patients undergoing carotid artery stenting were enrolled at nine centers in Europe. Follow‐up assessments included neurological exams, duplex ultrasound, 12‐lead electrocardiogram, and cardiac enzyme analysis. The primary endpoint was the 30‐day composite rate of stroke, death, and myocardial infarctions versus a prespecified performance goal. Secondary endpoints included procedure success, device success, and target lesion revascularization. Results: The study population was predominantly male (74.6%) with a mean age of 69.3 ± 8.9 years and 67% of subjects met at least one criterion placing them at an elevated risk for adverse events following carotid endarterectomy. All patients were treated successfully with the study device. There were no deaths or strokes within 30 days of the index procedure. One subject (1.5%) experienced a non‐ST elevation myocardial infarction at day 17. The primary endpoint was met with a 30‐day major adverse events rate of 1.5% (1/67). Through 12‐month follow‐up, there were no strokes, neurological deaths, target lesion revascularizations, or instances of in‐stent‐restenosis. Conclusions: Results from this study demonstrate the Neuroguard IEP system is safe and feasible with a stroke/death rate of 0% at 30 days. A large pivotal study is currently underway. … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 100:Issue 6(2022)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 100:Issue 6(2022)
- Issue Display:
- Volume 100, Issue 6 (2022)
- Year:
- 2022
- Volume:
- 100
- Issue:
- 6
- Issue Sort Value:
- 2022-0100-0006-0000
- Page Start:
- 1090
- Page End:
- 1099
- Publication Date:
- 2022-10-13
- Subjects:
- carotid artery stenting -- cerebral embolic protection -- periprocedural stroke
Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.30410 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 24433.xml