BL‐11C Micro‐MX: a high‐flux microfocus macromolecular‐crystallography beamline for micrometre‐sized protein crystals at Pohang Light Source II. (2nd June 2021)
- Record Type:
- Journal Article
- Title:
- BL‐11C Micro‐MX: a high‐flux microfocus macromolecular‐crystallography beamline for micrometre‐sized protein crystals at Pohang Light Source II. (2nd June 2021)
- Main Title:
- BL‐11C Micro‐MX: a high‐flux microfocus macromolecular‐crystallography beamline for micrometre‐sized protein crystals at Pohang Light Source II
- Authors:
- Gu, Do-Heon
Eo, Cheolsoo
Hwangbo, Seung-A
Ha, Sung-Chul
Kim, Jin Hong
Kim, Hyoyun
Lee, Chae-Soon
Seo, In Deuk
Yun, Young Duck
Lee, Woulwoo
Choi, Hyeongju
Kim, Jangwoo
Lim, Jun
Rah, Seungyu
Kim, Jeong-Sun
Lee, Jie-Oh
Kim, Yeon-Gil
Park, Suk-Youl - Abstract:
- Abstract : A new protein crystallography beamline (BL‐11C) has been constructed at Pohang Light Source II. The BL‐11C beamline allows routine protein‐structure determinations under a robot sample‐mounting system and room‐temperature structure determinations through synchrotron serial crystallography experiments. Abstract : BL‐11C, a new protein crystallography beamline, is an in‐vacuum undulator‐based microfocus beamline used for macromolecular crystallography at the Pohang Accelerator Laboratory and it was made available to users in June 2017. The beamline is energy tunable in the range 5.0–20 keV to support conventional single‐ and multi‐wavelength anomalous‐dispersion experiments against a wide range of heavy metals. At the standard working energy of 12.659 keV, the monochromated beam is focused to 4.1 µm (V) × 8.5 µm (H) full width at half‐maximum at the sample position and the measured photon flux is 1.3 × 10 12 photons s −1 . The experimental station is equipped with a Pilatus3 6M detector, a micro‐diffractometer (MD2S) incorporating a multi‐axis goniometer, and a robotic sample exchanger (CATS) with a dewar capacity of 90 samples. This beamline is suitable for structural determination of weakly diffracting crystalline substances, such as biomaterials, including protein, nucleic acids and their complexes. In addition, serial crystallography experiments for determining crystal structures at room temperature are possible. Herein, the current beamline characteristics,Abstract : A new protein crystallography beamline (BL‐11C) has been constructed at Pohang Light Source II. The BL‐11C beamline allows routine protein‐structure determinations under a robot sample‐mounting system and room‐temperature structure determinations through synchrotron serial crystallography experiments. Abstract : BL‐11C, a new protein crystallography beamline, is an in‐vacuum undulator‐based microfocus beamline used for macromolecular crystallography at the Pohang Accelerator Laboratory and it was made available to users in June 2017. The beamline is energy tunable in the range 5.0–20 keV to support conventional single‐ and multi‐wavelength anomalous‐dispersion experiments against a wide range of heavy metals. At the standard working energy of 12.659 keV, the monochromated beam is focused to 4.1 µm (V) × 8.5 µm (H) full width at half‐maximum at the sample position and the measured photon flux is 1.3 × 10 12 photons s −1 . The experimental station is equipped with a Pilatus3 6M detector, a micro‐diffractometer (MD2S) incorporating a multi‐axis goniometer, and a robotic sample exchanger (CATS) with a dewar capacity of 90 samples. This beamline is suitable for structural determination of weakly diffracting crystalline substances, such as biomaterials, including protein, nucleic acids and their complexes. In addition, serial crystallography experiments for determining crystal structures at room temperature are possible. Herein, the current beamline characteristics, technical information for users and some recent scientific highlights are described. … (more)
- Is Part Of:
- Journal of synchrotron radiation. Volume 28:Part 4(2021)
- Journal:
- Journal of synchrotron radiation
- Issue:
- Volume 28:Part 4(2021)
- Issue Display:
- Volume 28, Issue 4, Part 4 (2021)
- Year:
- 2021
- Volume:
- 28
- Issue:
- 4
- Part:
- 4
- Issue Sort Value:
- 2021-0028-0004-0004
- Page Start:
- 1210
- Page End:
- 1215
- Publication Date:
- 2021-06-02
- Subjects:
- beamlines -- microfocus -- macromolecular crystallography -- protein structures -- serial crystallography
Synchrotron radiation -- Periodicals
Free electron lasers -- Periodicals
539.73505 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1107/S16005775 ↗
http://journals.iucr.org/s/journalhomepage.html ↗
http://www.blackwell-synergy.com/openurl?genre=journal&issn=0909-0495 ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1107/S1600577521004355 ↗
- Languages:
- English
- ISSNs:
- 0909-0495
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5068.035000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 24417.xml