Evaluation of two different vacuum-assisted breast biopsy systems: Mammotome® system 11G/8G vs. ATEC® system 12G/9G. (March 2013)
- Record Type:
- Journal Article
- Title:
- Evaluation of two different vacuum-assisted breast biopsy systems: Mammotome® system 11G/8G vs. ATEC® system 12G/9G. (March 2013)
- Main Title:
- Evaluation of two different vacuum-assisted breast biopsy systems: Mammotome® system 11G/8G vs. ATEC® system 12G/9G
- Authors:
- Order, Berndt-Michael
Schaefer, Philipp J
Peters, G
Eckmann-Scholz, Christel
Hilpert, Felix
Strauss, Alexander
Warneke, Viktoria
Mathiak, Micaela
Heller, Martin
Jonat, Walter
Schaefer, Fritz KW - Abstract:
- Background: Breast cancer screening programs have been established worldwide and early detection of breast cancer has increased steadily. The most common way to confirm dignity of non-palpable and sonographically-occult suspicious findings on mammography is the stereotactically-guided vacuum-assisted breast biopsy Purpose: To compare two stereotactically guided vacuum-assisted breast biopsy systems measuring time effectiveness and quality of harvested material in clinical practice. Material and Methods: One hundred and forty-six patients presenting with suspicious microcalcifications on mammography were included in the study. Biopsies were carried out with either the Mammotome ® system (11-gauge and 8-gauge) or the ATEC ® system (12-gauge and 9-gauge). Lesions with a diameter <15 mm on mammography were biopsied with 11-gauge or 12-gauge devices whereas lesions >15 mm were targeted with 8-gauge and 9-gauge. Mammotome ® system 8-gauge device was used in 34 patients, the 11-gauge system in 37 patients. The ATEC ® system 9-gauge system was used in 37 patients and 12-gauge in 38 patients. Time was taken, focusing on preparing the system, time of collecting the samples, preparing the samples, and cleaning the site. During the biopsies 24 samples were taken. The histologic quality of the tissue samples was judged by a pathologist in a blinded fashion according to a specimen grading classification concerning tissue fragmentation, artefacts, and the adequacy of the tissue forBackground: Breast cancer screening programs have been established worldwide and early detection of breast cancer has increased steadily. The most common way to confirm dignity of non-palpable and sonographically-occult suspicious findings on mammography is the stereotactically-guided vacuum-assisted breast biopsy Purpose: To compare two stereotactically guided vacuum-assisted breast biopsy systems measuring time effectiveness and quality of harvested material in clinical practice. Material and Methods: One hundred and forty-six patients presenting with suspicious microcalcifications on mammography were included in the study. Biopsies were carried out with either the Mammotome ® system (11-gauge and 8-gauge) or the ATEC ® system (12-gauge and 9-gauge). Lesions with a diameter <15 mm on mammography were biopsied with 11-gauge or 12-gauge devices whereas lesions >15 mm were targeted with 8-gauge and 9-gauge. Mammotome ® system 8-gauge device was used in 34 patients, the 11-gauge system in 37 patients. The ATEC ® system 9-gauge system was used in 37 patients and 12-gauge in 38 patients. Time was taken, focusing on preparing the system, time of collecting the samples, preparing the samples, and cleaning the site. During the biopsies 24 samples were taken. The histologic quality of the tissue samples was judged by a pathologist in a blinded fashion according to a specimen grading classification concerning tissue fragmentation, artefacts, and the adequacy of the tissue for diagnosis. Results: The median overall time for the Mammotome ® system was 879 s (11-gauge) and 934 s (8-gauge) and for the ATEC ® system 671 s (12-gauge) and 673 s (9-gauge). The ATEC ® system displays a significantly shorter overall time for small and large biopsy devices (U-test, P < 0.001). Concerning the mean time difference of the overall time comparing small and large systems the ATEC ® system was 267.6 s faster using the small and 244.8 s faster using the large system. Comparing the histologic quality of tissue samples the Mammotome ® system shows significantly higher values for the large and the small system (Chi-square test, P < 0.001). Conclusion: Both biopsy systems meet all requirements for daily practice and confirm the diagnosis of suspicious microcalcifications. The ATEC ® system was observed to be faster but this difference of about 250 s might not be relevant in daily practice. The Mammotome ® system provides a better histologic quality of tissue samples. … (more)
- Is Part Of:
- Acta radiologica. Volume 54:Number 2(2013)
- Journal:
- Acta radiologica
- Issue:
- Volume 54:Number 2(2013)
- Issue Display:
- Volume 54, Issue 2 (2013)
- Year:
- 2013
- Volume:
- 54
- Issue:
- 2
- Issue Sort Value:
- 2013-0054-0002-0000
- Page Start:
- 137
- Page End:
- 143
- Publication Date:
- 2013-03
- Subjects:
- Vacuum-assisted biopsy -- breast -- histologic quality
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1258/ar.2012.120420 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24390.xml