Dual-source CT coronary angiography involving injection protocol with iodine load tailored to patient body weight and body mass index: Estimation of optimal contrast material dose. (March 2013)
- Record Type:
- Journal Article
- Title:
- Dual-source CT coronary angiography involving injection protocol with iodine load tailored to patient body weight and body mass index: Estimation of optimal contrast material dose. (March 2013)
- Main Title:
- Dual-source CT coronary angiography involving injection protocol with iodine load tailored to patient body weight and body mass index: Estimation of optimal contrast material dose
- Authors:
- Zhu, Xiaomei
Zhu, Yinsu
Xu, Hai
Yang, Guanyu
Tang, Lijun
Xu, Yi - Abstract:
- Background: Body mass index (BMI) has a positive linear influence on arterial attenuation at coronary CT angiography involving injection protocol with dose linearly tailored to body weight (BW). Excessive contrast material may inadvertently be given in heavier patients when the dose is determined by BW only. Purpose: To investigate the effect of injection protocol with dose of contrast material (CM) tailored to BW and BMI on coronary arterial attenuation, contrast-to-noise ratio, and image noise at dual-source CT coronary angiography (DSCT-CA). Material and Methods: A total of 233 consecutive patients (mean age, 60.2 years) undergoing DSCT-CA were included. Image acquisition protocol was standardized (120 kV, 380 mAs, and retrospective electrocardiograph-triggered DSCT-CA). CM dosage calculation was randomly categorized into groups: a BW group and a BW-BMI group. CM flow rate in both groups was calculated as dosage divided by scan time plus 8 s. Correlations between BW, BMI, and attenuations of ascending aorta (AA) above coronary ostia, left main coronary artery (LM), proximal right coronary artery (RCA), left anterior descending (LAD), and left circumflex artery (LCX), contrast to noise ratio of LM (LMCNR ) and RCA (RCACNR ), and image noise were evaluated with simple linear regression for two groups individually. Results: In BW group, attenuations of AA and coronary arteries showed positive linear correlations to BW and BMI. In contrast, no relationships were found inBackground: Body mass index (BMI) has a positive linear influence on arterial attenuation at coronary CT angiography involving injection protocol with dose linearly tailored to body weight (BW). Excessive contrast material may inadvertently be given in heavier patients when the dose is determined by BW only. Purpose: To investigate the effect of injection protocol with dose of contrast material (CM) tailored to BW and BMI on coronary arterial attenuation, contrast-to-noise ratio, and image noise at dual-source CT coronary angiography (DSCT-CA). Material and Methods: A total of 233 consecutive patients (mean age, 60.2 years) undergoing DSCT-CA were included. Image acquisition protocol was standardized (120 kV, 380 mAs, and retrospective electrocardiograph-triggered DSCT-CA). CM dosage calculation was randomly categorized into groups: a BW group and a BW-BMI group. CM flow rate in both groups was calculated as dosage divided by scan time plus 8 s. Correlations between BW, BMI, and attenuations of ascending aorta (AA) above coronary ostia, left main coronary artery (LM), proximal right coronary artery (RCA), left anterior descending (LAD), and left circumflex artery (LCX), contrast to noise ratio of LM (LMCNR ) and RCA (RCACNR ), and image noise were evaluated with simple linear regression for two groups individually. Results: In BW group, attenuations of AA and coronary arteries showed positive linear correlations to BW and BMI. In contrast, no relationships were found in BW-BMI group. LMCNR and RCACNR were inversely determined by BW and BMI in both groups. Image noise increased with BW and BMI increasing in two groups. Conclusion: BMI has a positive linear influence on arterial attenuation with fixed iodine per BW. The injection protocol with CM dose tailored to BW and BMI is reasonable during DSCT-CA. … (more)
- Is Part Of:
- Acta radiologica. Volume 54:Number 2(2013)
- Journal:
- Acta radiologica
- Issue:
- Volume 54:Number 2(2013)
- Issue Display:
- Volume 54, Issue 2 (2013)
- Year:
- 2013
- Volume:
- 54
- Issue:
- 2
- Issue Sort Value:
- 2013-0054-0002-0000
- Page Start:
- 149
- Page End:
- 155
- Publication Date:
- 2013-03
- Subjects:
- Body mass index -- body weight -- coronary CT angiography -- contrast to noise ratio -- image noise
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1258/ar.2012.120362 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24390.xml