Prevalence of thyroid dysfunction and effect of contrast medium on thyroid metabolism in cardiac patients undergoing coronary angiography. (February 2013)
- Record Type:
- Journal Article
- Title:
- Prevalence of thyroid dysfunction and effect of contrast medium on thyroid metabolism in cardiac patients undergoing coronary angiography. (February 2013)
- Main Title:
- Prevalence of thyroid dysfunction and effect of contrast medium on thyroid metabolism in cardiac patients undergoing coronary angiography
- Authors:
- Marraccini, Paolo
Bianchi, Massimiliano
Bottoni, Antonio
Mazzarisi, Alessandro
Coceani, Michele
Molinaro, Sabrina
Lorenzoni, Valentina
Landi, Patrizia
Iervasi, Giorgio - Abstract:
- Background: Iodinated contrast media (CM) may influence thyroid function. Precautions are generally taken in patients with hyperthyroidism, even if subclinical, whereas the risks in patients with hypothyroidism or low triiodothyronine (T3) syndrome are not considered as appreciable. Purpose: To assess the presence and type of thyroid dysfunction in patients admitted for coronary angiography (CA), to assess the concentration of free-iodide in five non-ionic CM, and to evaluate changes in thyroid function after CA in patients with low T3 syndrome. Material and Methods: We measured free T3, free thyroxine (T4), and thyroid-stimulating hormone (TSH) in 1752 consecutive patients prior to CA and free-iodide in five non-ionic CM. Urinary free-iodide before and 24 h after CA, and thyroid hormone profile 48 h after CA were also made in 17 patients with low T3 syndrome. Patients were followed up for an average duration of 63.5 months. Results: The patients were divided into four groups: euthyroidism (60%), low T3 syndrome (28%), hypothyroidism (10%), and hyperthyroidism (2%). The free-iodide resulted far below the recommended limit of 50 μg/mL in all tested CM. In low T3 syndrome, 24-h free-iodide increased after CA from 99.9± 63 ug to 12276±9285 ug (P< 0.0001). A reduction in TSH (4.97±1.1 vs. 4.17±1.1 mUI/mL, P < 0.01) and free T3 (1.44±0.2 vs. 1.25±0.3 pg/mL, P < 0.01), with an increase in free T4 (11.3±2.9 vs. 12.5±3.4 pg/dL, P < 0.001), was found. Patients with functional thyroidBackground: Iodinated contrast media (CM) may influence thyroid function. Precautions are generally taken in patients with hyperthyroidism, even if subclinical, whereas the risks in patients with hypothyroidism or low triiodothyronine (T3) syndrome are not considered as appreciable. Purpose: To assess the presence and type of thyroid dysfunction in patients admitted for coronary angiography (CA), to assess the concentration of free-iodide in five non-ionic CM, and to evaluate changes in thyroid function after CA in patients with low T3 syndrome. Material and Methods: We measured free T3, free thyroxine (T4), and thyroid-stimulating hormone (TSH) in 1752 consecutive patients prior to CA and free-iodide in five non-ionic CM. Urinary free-iodide before and 24 h after CA, and thyroid hormone profile 48 h after CA were also made in 17 patients with low T3 syndrome. Patients were followed up for an average duration of 63.5 months. Results: The patients were divided into four groups: euthyroidism (60%), low T3 syndrome (28%), hypothyroidism (10%), and hyperthyroidism (2%). The free-iodide resulted far below the recommended limit of 50 μg/mL in all tested CM. In low T3 syndrome, 24-h free-iodide increased after CA from 99.9± 63 ug to 12276±9285 ug (P< 0.0001). A reduction in TSH (4.97±1.1 vs. 4.17±1.1 mUI/mL, P < 0.01) and free T3 (1.44±0.2 vs. 1.25±0.3 pg/mL, P < 0.01), with an increase in free T4 (11.3±2.9 vs. 12.5±3.4 pg/dL, P < 0.001), was found. Patients with functional thyroid disease in the follow-up had a significant lower rate survival compared to euthyroid patients (90.7 vs. 82.2%, P < 0.00001). Conclusion: Thyroid dysfunction is frequent in patients who perform a CA, and low T3 syndrome is the predominant feature. The administration of contrast medium may further compromise the thyroid function. … (more)
- Is Part Of:
- Acta radiologica. Volume 54:Number 1(2013)
- Journal:
- Acta radiologica
- Issue:
- Volume 54:Number 1(2013)
- Issue Display:
- Volume 54, Issue 1 (2013)
- Year:
- 2013
- Volume:
- 54
- Issue:
- 1
- Issue Sort Value:
- 2013-0054-0001-0000
- Page Start:
- 42
- Page End:
- 47
- Publication Date:
- 2013-02
- Subjects:
- Ischemic heart disease -- thyroid disease -- contrast medium
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1258/ar.2012.120326 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24410.xml