Paclitaxel-Eluting Balloon vs. Standard Angioplasty to Reduce Recurrent Restenosis in Diabetic Patients With In-Stent Restenosis of the Superficial Femoral and Proximal Popliteal Arteries: The DEBATE-ISR Study. (February 2014)
- Record Type:
- Journal Article
- Title:
- Paclitaxel-Eluting Balloon vs. Standard Angioplasty to Reduce Recurrent Restenosis in Diabetic Patients With In-Stent Restenosis of the Superficial Femoral and Proximal Popliteal Arteries: The DEBATE-ISR Study. (February 2014)
- Main Title:
- Paclitaxel-Eluting Balloon vs. Standard Angioplasty to Reduce Recurrent Restenosis in Diabetic Patients With In-Stent Restenosis of the Superficial Femoral and Proximal Popliteal Arteries: The DEBATE-ISR Study
- Authors:
- Liistro, Francesco
Angioli, Paolo
Porto, Italo
Ricci, Lucia
Ducci, Kenneth
Grotti, Simone
Falsini, Giovanni
Ventoruzzo, Giorgio
Turini, Filippo
Bellandi, Guido
Bolognese, Leonardo - Abstract:
- Purpose: To test the ability of a drug-eluting balloon (DEB) to reduce recurrent in-stent restenosis (ISR) in diabetic patients with femoropopliteal stents. Methods: A prospective all-comers study [Drug-Eluting Balloon in Peripheral Intervention for In-Stent Restenosis (DEBATE-ISR); ClinicalTrials.gov identifier NCT01558531] of symptomatic diabetic patients with femoropopliteal ISR undergoing treatment with paclitaxel-eluting balloons was designed to compare their 12-month recurrent restenosis rate with that of historical diabetic controls. From January 2010 to December 2011, 44 consecutive diabetic patients (32 men; mean age 74±11 years) were treated with DEBs and enrolled in the study. The control group comprised 42 diabetic patients (23 men; mean age 76±7 years) treated with a conventional balloon for femoropopliteal ISR from 2008 to 2009. Results: No significant differences in terms of clinical, angiographic, or procedural characteristics were observed between the study groups. Lesion length was 132±86 mm in the DEB group vs. 137±82 mm in the BA group. Procedural success, defined as a residual stenosis <30% in the restenotic segment (stent +5 mm at proximal and distal edges), was obtained in all treated lesions. At 1-year follow-up, 6 patients died (3 in each group), and 1 patient in the BA group underwent major amputation. Recurrent restenosis, assessed by angiography (66%) or ultrasound (34%), occurred in 8/41 (19.5%) patients in the DEB group vs. 28/39 (71.8%) in thePurpose: To test the ability of a drug-eluting balloon (DEB) to reduce recurrent in-stent restenosis (ISR) in diabetic patients with femoropopliteal stents. Methods: A prospective all-comers study [Drug-Eluting Balloon in Peripheral Intervention for In-Stent Restenosis (DEBATE-ISR); ClinicalTrials.gov identifier NCT01558531] of symptomatic diabetic patients with femoropopliteal ISR undergoing treatment with paclitaxel-eluting balloons was designed to compare their 12-month recurrent restenosis rate with that of historical diabetic controls. From January 2010 to December 2011, 44 consecutive diabetic patients (32 men; mean age 74±11 years) were treated with DEBs and enrolled in the study. The control group comprised 42 diabetic patients (23 men; mean age 76±7 years) treated with a conventional balloon for femoropopliteal ISR from 2008 to 2009. Results: No significant differences in terms of clinical, angiographic, or procedural characteristics were observed between the study groups. Lesion length was 132±86 mm in the DEB group vs. 137±82 mm in the BA group. Procedural success, defined as a residual stenosis <30% in the restenotic segment (stent +5 mm at proximal and distal edges), was obtained in all treated lesions. At 1-year follow-up, 6 patients died (3 in each group), and 1 patient in the BA group underwent major amputation. Recurrent restenosis, assessed by angiography (66%) or ultrasound (34%), occurred in 8/41 (19.5%) patients in the DEB group vs. 28/39 (71.8%) in the BA group (p<0.001). Target lesion revascularization for symptomatic recurrent restenosis was performed in 6/44 (13.6%) patients in the DEB vs.13/42 (31.0%) in the BA group (p=0.045). Conclusion: Using DEB for treating femoropopliteal ISR led to a significant reduction in recurrent restenosis and repeat angioplasty at 1-year follow-up as compared to historical controls. … (more)
- Is Part Of:
- Journal of endovascular therapy. Volume 21:Number 1(2014)
- Journal:
- Journal of endovascular therapy
- Issue:
- Volume 21:Number 1(2014)
- Issue Display:
- Volume 21, Issue 1 (2014)
- Year:
- 2014
- Volume:
- 21
- Issue:
- 1
- Issue Sort Value:
- 2014-0021-0001-0000
- Page Start:
- 1
- Page End:
- 8
- Publication Date:
- 2014-02
- Subjects:
- peripheral artery disease -- drug-eluting balloon -- paclitaxel -- restenosis -- in-stent restenosis -- recurrent restenosis -- femoropopliteal segment -- superficial femoral artery -- popliteal artery -- diabetes -- balloon angioplasty -- target lesion revascularization -- comparative study -- outcome analysis
Blood-vessels -- Endoscopic surgery -- Periodicals
Angioscopy -- Periodicals
Intravenous catheterization -- Periodicals
Peripheral vascular diseases -- Treatment -- Periodicals
Vascular Surgical Procedures -- Periodicals
Angioscopy -- Periodicals
Catheterization, Peripheral -- Periodicals
Peripheral Vascular Diseases -- therapy -- Periodicals
Angioscopie
Maladies vasculaires périphériques
617.413 - Journal URLs:
- http://jet.sagepub.com/ ↗
http://www.jevt.org ↗
http://www.uk.sagepub.com ↗ - DOI:
- 10.1583/13-4420R.1 ↗
- Languages:
- English
- ISSNs:
- 1526-6028
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24402.xml