A Preliminary In Vivo Assessment of Anterior Cruciate Ligament–Deficient Knee Kinematics With the KneeM Device: A New Method to Assess Rotatory Laxity Using Open MRI. Issue 3 (12th March 2014)
- Record Type:
- Journal Article
- Title:
- A Preliminary In Vivo Assessment of Anterior Cruciate Ligament–Deficient Knee Kinematics With the KneeM Device: A New Method to Assess Rotatory Laxity Using Open MRI. Issue 3 (12th March 2014)
- Main Title:
- A Preliminary In Vivo Assessment of Anterior Cruciate Ligament–Deficient Knee Kinematics With the KneeM Device
- Authors:
- Tardy, Nicolas
Marchand, Philippe
Kouyoumdjian, Pascal
Blin, Dominique
Demattei, Christophe
Asencio, Gérard - Abstract:
- Background: Methods of objectively measuring rotational knee laxity are either experimental or difficult to use in daily practice. A new method has been developed to quantitatively assess rotatory laxity using an open MRI system and new tool, the KneeM device. Purpose/Hypothesis: To perform a preliminary evaluation of a novel knee rotation measurement device to assess knee kinematics during flexion in an MRI field, in both anterior cruciate ligament (ACL)–deficient and healthy contralateral knees. The hypothesis was that the KneeM device would allow in vivo reproduction and analysis of knee kinematics during flexion in healthy and ACL-deficient knees. Study Design: Controlled laboratory study. Methods: Ten subjects (7 men and 3 women; mean age ± standard deviation, 32.3 ± 9.4 years) with ACL-deficient knees and contralateral uninjured knees participated in the study. An open MRI was performed with the KneeM device at a mean 4.9 months (range, 3.0-7 months) after ACL injury. The device exerted on the knee an anterior drawer force of 100 N, with an internal rotation of 20°, through the range of flexion (0°, 20°, 40°, and 60°). Both ACL-deficient and healthy contralateral knees were analyzed using the Iwaki method. Results: There was no statistical difference of anterior translation in the medial compartment between intact and ACL-deficient knees at all degrees of flexion. However, significant differences in the anterior translation of the lateral compartment were observedBackground: Methods of objectively measuring rotational knee laxity are either experimental or difficult to use in daily practice. A new method has been developed to quantitatively assess rotatory laxity using an open MRI system and new tool, the KneeM device. Purpose/Hypothesis: To perform a preliminary evaluation of a novel knee rotation measurement device to assess knee kinematics during flexion in an MRI field, in both anterior cruciate ligament (ACL)–deficient and healthy contralateral knees. The hypothesis was that the KneeM device would allow in vivo reproduction and analysis of knee kinematics during flexion in healthy and ACL-deficient knees. Study Design: Controlled laboratory study. Methods: Ten subjects (7 men and 3 women; mean age ± standard deviation, 32.3 ± 9.4 years) with ACL-deficient knees and contralateral uninjured knees participated in the study. An open MRI was performed with the KneeM device at a mean 4.9 months (range, 3.0-7 months) after ACL injury. The device exerted on the knee an anterior drawer force of 100 N, with an internal rotation of 20°, through the range of flexion (0°, 20°, 40°, and 60°). Both ACL-deficient and healthy contralateral knees were analyzed using the Iwaki method. Results: There was no statistical difference of anterior translation in the medial compartment between intact and ACL-deficient knees at all degrees of flexion. However, significant differences in the anterior translation of the lateral compartment were observed between ACL-deficient and intact contralateral knees at 0° and 20° of flexion ( P = .005 and P = .002, respectively). Between 20° and 40°, the lateral plateau of ACL-deficient knees translated 7.7 mm posteriorly, whereas the medial compartment remained stable, reflecting a sudden external rotation of the lateral plateau under the femoral condyle. Conclusion: This preliminary study suggests that measurement of tibiofemoral movements in both compartments during flexion using the KneeM device was useful for quantifying rotatory laxity in ACL-deficient knees. Moreover, this device seemed to allow a "mechanized pivot shift" and allowed reproduction of the "pivot" phase in the MRI field between 20° and 40° of flexion. Clinical Relevance: This device could be used for diagnostic purposes or to investigate the outcomes of ACL reconstructions. … (more)
- Is Part Of:
- Orthopaedic journal of sports medicine. Volume 2:Issue 3(2014)
- Journal:
- Orthopaedic journal of sports medicine
- Issue:
- Volume 2:Issue 3(2014)
- Issue Display:
- Volume 2, Issue 3 (2014)
- Year:
- 2014
- Volume:
- 2
- Issue:
- 3
- Issue Sort Value:
- 2014-0002-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2014-03-12
- Subjects:
- knee -- pivot shift -- rotatory laxity -- open MRI -- MRI-compatible device
Sports medicine -- Periodicals
Orthopedics -- Periodicals
Arthroscopy -- Periodicals
Arthroplasty -- Periodicals
Knee -- Surgery -- Periodicals
616.7 - Journal URLs:
- http://www.sagepublications.com/ ↗
- DOI:
- 10.1177/2325967114525583 ↗
- Languages:
- English
- ISSNs:
- 2325-9671
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24413.xml