Compressed sensing (CS) MP2RAGE versus standard MPRAGE: A comparison of derived brain volume measurements. (November 2022)
- Record Type:
- Journal Article
- Title:
- Compressed sensing (CS) MP2RAGE versus standard MPRAGE: A comparison of derived brain volume measurements. (November 2022)
- Main Title:
- Compressed sensing (CS) MP2RAGE versus standard MPRAGE: A comparison of derived brain volume measurements
- Authors:
- Ferraro, Pilar Maria
Gualco, Lorenzo
Costagli, Mauro
Schiavi, Simona
Ponzano, Marta
Signori, Alessio
Massa, Federico
Pardini, Matteo
Castellan, Lucio
Levrero, Fabrizio
Zacà, Domenico
Piredda, Gian Franco
Hilbert, Tom
Kober, Tobias
Roccatagliata, Luca - Abstract:
- Abstract: Purpose: T1 Magnetization Prepared Two Rapid Acquisition Gradient Echo (MP2RAGE) with compress sensing (CS) has been proposed as an improvement of the standard MPRAGE sequence with multiple advantages including reduced acquisition time needed to provide a quantitative 3D anatomical image coupled with T1-map. Here we investigated the agreement between FreeSurfer-derived volume measurements obtained from MPRAGE and CS MP2RAGE acquisitions. Methods: MPRAGE and CS MP2RAGE images of 37 subjects (14 patients with neurodegenerative disorders and 23 healthy controls) were acquired on a 3 T MR scanner and grey matter volumes were extracted using standard FreeSurfer parcellation. Lin's concordance correlation coefficient (Lin's CCC), Bland-Altman analysis, Passing-Bablok regression and DICE similarity coefficient were calculated to assess the agreement between the two. Results: We found a good correspondence for most of the regions examined, with 93.5 % of them showing a mean DICE index >0.70. Poorer results were found with Lin's CCC especially for subcortical labels across patients. The Bland-Altman analysis showed CS MP2RAGE tended to measure lower cortical volumes compared to MPRAGE but in most cases the difference wasn't statistically relevant. The Passing-Bablock regression indicated overall an absence of systematic constant and proportional bias when CS MP2RAGE was used instead of MPRAGE. Conclusions: We found a good concordance for volumes obtained from MPRAGE and CSAbstract: Purpose: T1 Magnetization Prepared Two Rapid Acquisition Gradient Echo (MP2RAGE) with compress sensing (CS) has been proposed as an improvement of the standard MPRAGE sequence with multiple advantages including reduced acquisition time needed to provide a quantitative 3D anatomical image coupled with T1-map. Here we investigated the agreement between FreeSurfer-derived volume measurements obtained from MPRAGE and CS MP2RAGE acquisitions. Methods: MPRAGE and CS MP2RAGE images of 37 subjects (14 patients with neurodegenerative disorders and 23 healthy controls) were acquired on a 3 T MR scanner and grey matter volumes were extracted using standard FreeSurfer parcellation. Lin's concordance correlation coefficient (Lin's CCC), Bland-Altman analysis, Passing-Bablok regression and DICE similarity coefficient were calculated to assess the agreement between the two. Results: We found a good correspondence for most of the regions examined, with 93.5 % of them showing a mean DICE index >0.70. Poorer results were found with Lin's CCC especially for subcortical labels across patients. The Bland-Altman analysis showed CS MP2RAGE tended to measure lower cortical volumes compared to MPRAGE but in most cases the difference wasn't statistically relevant. The Passing-Bablock regression indicated overall an absence of systematic constant and proportional bias when CS MP2RAGE was used instead of MPRAGE. Conclusions: We found a good concordance for volumes obtained from MPRAGE and CS MP2RAGE images using FreeSurfer, suggesting a possible role of CS MP2RAGE for structural analysis with significant advantages like shorter acquisition time and the possibility to simultaneously obtain quantitative T1-maps of the brain enriching the diagnostic power of this technique. … (more)
- Is Part Of:
- Physica medica. Volume 103(2022)
- Journal:
- Physica medica
- Issue:
- Volume 103(2022)
- Issue Display:
- Volume 103, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 103
- Issue:
- 2022
- Issue Sort Value:
- 2022-0103-2022-0000
- Page Start:
- 166
- Page End:
- 174
- Publication Date:
- 2022-11
- Subjects:
- MPRAGE -- CS MP2RAGE -- FreeSurfer -- Brain volume
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2022.10.023 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24376.xml