Assessment of CBCT–based synthetic CT generation accuracy for adaptive radiotherapy planning. Issue 11 (5th October 2022)
- Record Type:
- Journal Article
- Title:
- Assessment of CBCT–based synthetic CT generation accuracy for adaptive radiotherapy planning. Issue 11 (5th October 2022)
- Main Title:
- Assessment of CBCT–based synthetic CT generation accuracy for adaptive radiotherapy planning
- Authors:
- O'Hara, Christopher J.
Bird, David
Al‐Qaisieh, Bashar
Speight, Richard - Abstract:
- Abstract: Purpose: Cone‐beam CT (CBCT)–based synthetic CT (sCT) dose calculation has the potential to make the adaptive radiotherapy (ART) pathway more efficient while removing subjectivity. This study assessed four sCT generation methods using 15 head‐and‐neck rescanned ART patients. Each patient's planning CT (pCT), rescan CT (rCT), and CBCT post‐rCT was acquired with the CBCT deformably registered to the rCT (dCBCT). Methods: The four methods investigated were as follows: method 1—deformably registering the pCT to the dCBCT. Method 2—assigning six mass density values to the dCBCT. Method 3—iteratively removing artifacts and correcting the dCBCT Hounsfield units (HU). Method 4—using a cycle general adversarial network machine learning model (trained with 45 paired pCT and CBCT). Treatment plans were created on the rCT and recalculated on each sCT. Planning target volume (PTV) and organ‐at‐risk (OAR) structures were contoured by clinicians on the rCT (high‐dose PTV, low‐dose PTV, spinal canal, larynx, brainstem, and parotids) to allow the assessment of dose–volume histogram statistics at clinically relevant points. Results: The HU mean absolute error (MAE) and minimum dose gamma index pass rate (2%/2 mm) were calculated, and the generation time was measured for 15 patients using the rCT as the comparator. For methods 1–4 the MAE, gamma index analysis, and generation time were as follows: 59.7 HU, 100.0%, and 143 s; 164.2 HU, 95.2%, and 232 s; 75.7 HU, 99.9%, and 153 s; andAbstract: Purpose: Cone‐beam CT (CBCT)–based synthetic CT (sCT) dose calculation has the potential to make the adaptive radiotherapy (ART) pathway more efficient while removing subjectivity. This study assessed four sCT generation methods using 15 head‐and‐neck rescanned ART patients. Each patient's planning CT (pCT), rescan CT (rCT), and CBCT post‐rCT was acquired with the CBCT deformably registered to the rCT (dCBCT). Methods: The four methods investigated were as follows: method 1—deformably registering the pCT to the dCBCT. Method 2—assigning six mass density values to the dCBCT. Method 3—iteratively removing artifacts and correcting the dCBCT Hounsfield units (HU). Method 4—using a cycle general adversarial network machine learning model (trained with 45 paired pCT and CBCT). Treatment plans were created on the rCT and recalculated on each sCT. Planning target volume (PTV) and organ‐at‐risk (OAR) structures were contoured by clinicians on the rCT (high‐dose PTV, low‐dose PTV, spinal canal, larynx, brainstem, and parotids) to allow the assessment of dose–volume histogram statistics at clinically relevant points. Results: The HU mean absolute error (MAE) and minimum dose gamma index pass rate (2%/2 mm) were calculated, and the generation time was measured for 15 patients using the rCT as the comparator. For methods 1–4 the MAE, gamma index analysis, and generation time were as follows: 59.7 HU, 100.0%, and 143 s; 164.2 HU, 95.2%, and 232 s; 75.7 HU, 99.9%, and 153 s; and 79.4 HU, 99.8%, and 112 s, respectively. Dose differences for PTVs and OARs were all <0.3 Gy except for method 2 (<0.5 Gy). Conclusion: All methods were considered clinically viable. The machine learning method was found to be most suitable for clinical implementation due to its high dosimetric accuracy and short generation time. Further investigation is required for larger anatomical changes between the CBCT and pCT and for other anatomical sites. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 23:Issue 11(2022)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 23:Issue 11(2022)
- Issue Display:
- Volume 23, Issue 11 (2022)
- Year:
- 2022
- Volume:
- 23
- Issue:
- 11
- Issue Sort Value:
- 2022-0023-0011-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2022-10-05
- Subjects:
- adaptive radiotherapy -- CBCT -- CBCT dosimetric accuracy -- CBCT‐based sCT -- synthetic CT
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.13737 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24379.xml