A 90‐channel triaxial magnetoencephalography system using optically pumped magnetometers. Issue 1 (5th September 2022)
- Record Type:
- Journal Article
- Title:
- A 90‐channel triaxial magnetoencephalography system using optically pumped magnetometers. Issue 1 (5th September 2022)
- Main Title:
- A 90‐channel triaxial magnetoencephalography system using optically pumped magnetometers
- Authors:
- Rea, Molly
Boto, Elena
Holmes, Niall
Hill, Ryan
Osborne, James
Rhodes, Natalie
Leggett, James
Rier, Lukas
Bowtell, Richard
Shah, Vishal
Brookes, Matthew J. - Abstract:
- Abstract: Magnetoencephalography (MEG) measures the small magnetic fields generated by current flow in neural networks, providing a noninvasive metric of brain function. MEG is well established as a powerful neuroscientific and clinical tool. However, current instrumentation is hampered by cumbersome cryogenic field‐sensing technologies. In contrast, MEG using optically pumped magnetometers (OPM‐MEG) employs small, lightweight, noncryogenic sensors that provide data with higher sensitivity and spatial resolution, a natural scanning environment (including participant movement), and adaptability to any age. However, OPM‐MEG is new and the optimum way to design a system is unknown. Here, we construct a novel, 90‐channel triaxial OPM‐MEG system and use it to map motor function during a naturalistic handwriting task. Results show that high‐precision magnetic field control reduced background fields to ∼200 pT, enabling free participant movement. Our triaxial array offered twice the total measured signal and better interference rejection compared to a conventional (single‐axis) design. We mapped neural oscillatory activity to the sensorimotor network, demonstrating significant differences in motor network activity and connectivity for left‐handed versus right‐handed handwriting. Repeatability across scans showed that we can map electrophysiological activity with an accuracy ∼4 mm. Overall, our study introduces a novel triaxial OPM‐MEG design and confirms its potential forAbstract: Magnetoencephalography (MEG) measures the small magnetic fields generated by current flow in neural networks, providing a noninvasive metric of brain function. MEG is well established as a powerful neuroscientific and clinical tool. However, current instrumentation is hampered by cumbersome cryogenic field‐sensing technologies. In contrast, MEG using optically pumped magnetometers (OPM‐MEG) employs small, lightweight, noncryogenic sensors that provide data with higher sensitivity and spatial resolution, a natural scanning environment (including participant movement), and adaptability to any age. However, OPM‐MEG is new and the optimum way to design a system is unknown. Here, we construct a novel, 90‐channel triaxial OPM‐MEG system and use it to map motor function during a naturalistic handwriting task. Results show that high‐precision magnetic field control reduced background fields to ∼200 pT, enabling free participant movement. Our triaxial array offered twice the total measured signal and better interference rejection compared to a conventional (single‐axis) design. We mapped neural oscillatory activity to the sensorimotor network, demonstrating significant differences in motor network activity and connectivity for left‐handed versus right‐handed handwriting. Repeatability across scans showed that we can map electrophysiological activity with an accuracy ∼4 mm. Overall, our study introduces a novel triaxial OPM‐MEG design and confirms its potential for high‐performance functional neuroimaging. Abstract : Magnetoencephalography (MEG) measures the tiny magnetic fields generated by current flow in the brain, but conventional MEG is hampered by cumbersome cryogenic field‐sensing technologies. Our wearable, 90‐channel triaxial optically‐pumped magnetometer (OPM) MEG system—in conjunction with precision magnetic field control that reduced background fields to ∼200 pT—is used here to map electrophysiological activity during handwriting to the motor cortex, with accuracy ∼4 mm. … (more)
- Is Part Of:
- Annals of the New York Academy of Sciences. Volume 1517:Issue 1(2022)
- Journal:
- Annals of the New York Academy of Sciences
- Issue:
- Volume 1517:Issue 1(2022)
- Issue Display:
- Volume 1517, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 1517
- Issue:
- 1
- Issue Sort Value:
- 2022-1517-0001-0000
- Page Start:
- 107
- Page End:
- 124
- Publication Date:
- 2022-09-05
- Subjects:
- electrophysiology -- human brain imaging -- magnetoencephalography -- optically pumped magnetometers
Medical sciences -- Periodicals
Medicine -- Periodicals
Science -- Periodicals
610 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1749-6632 ↗
http://www.blackwellpublishing.com/journal.asp?ref=0077-8923&site=1 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/nyas.14890 ↗
- Languages:
- English
- ISSNs:
- 0077-8923
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1031.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 24365.xml