Development and initial validation of a novel thread design for nonlocking cancellous screws. Issue 12 (10th March 2022)
- Record Type:
- Journal Article
- Title:
- Development and initial validation of a novel thread design for nonlocking cancellous screws. Issue 12 (10th March 2022)
- Main Title:
- Development and initial validation of a novel thread design for nonlocking cancellous screws
- Authors:
- Feng, Xiaoreng
Zhang, Sheng
Luo, Zhaopei
Liang, Hongfeng
Chen, Bin
Leung, Frankie - Abstract:
- Abstract: High failure rates have been associated with nonlocking cancellous screws with a typical buttress thread in patients with osteoporotic bone. This study aimed to develop a novel thread design and compare its fixation stability with that of a typical buttress thread. Nonlocking cancellous screws with a novel thread design (proximal flank angle of 120 degrees, a flat crest feature, a tip‐facing undercut feature) and nonlocking cancellous screws with a typical buttress thread were manufactured using stainless steel. Fixation stabilities were evaluated individually by the axial pullout and lateral migration tests, and they were evaluated in pairs together with a dynamic compression plate in an osteoporotic bone substitute (10 PCF polyurethane foam per ASTM F1839) under cyclic craniocaudal and torsional loadings. Pullout strength and lateral migration resistance for the individual screw test and the force, torque, and number of cycles required to achieve specific displacement and torsion for the multi‐screw test were comparatively analyzed between both screw types. A finite element analysis model was constructed to analyze the stress distributions in the bone tissue adjacent to the threads. The biomechanical test revealed the novel undercut thread had superior axial pullout strength, lateral migration resistance, and superior fixation stability when applied to a dynamic compression plate under cyclic craniocaudal loading and torsional loading than those in the typicalAbstract: High failure rates have been associated with nonlocking cancellous screws with a typical buttress thread in patients with osteoporotic bone. This study aimed to develop a novel thread design and compare its fixation stability with that of a typical buttress thread. Nonlocking cancellous screws with a novel thread design (proximal flank angle of 120 degrees, a flat crest feature, a tip‐facing undercut feature) and nonlocking cancellous screws with a typical buttress thread were manufactured using stainless steel. Fixation stabilities were evaluated individually by the axial pullout and lateral migration tests, and they were evaluated in pairs together with a dynamic compression plate in an osteoporotic bone substitute (10 PCF polyurethane foam per ASTM F1839) under cyclic craniocaudal and torsional loadings. Pullout strength and lateral migration resistance for the individual screw test and the force, torque, and number of cycles required to achieve specific displacement and torsion for the multi‐screw test were comparatively analyzed between both screw types. A finite element analysis model was constructed to analyze the stress distributions in the bone tissue adjacent to the threads. The biomechanical test revealed the novel undercut thread had superior axial pullout strength, lateral migration resistance, and superior fixation stability when applied to a dynamic compression plate under cyclic craniocaudal loading and torsional loading than those in the typical buttress thread. The finite element analysis simulation revealed that the novel thread can distribute stress more evenly without high‐stress concentration at the adjacent bone tissue when compared to that of a typical buttress thread. … (more)
- Is Part Of:
- Journal of orthopaedic research. Volume 40:Issue 12(2022)
- Journal:
- Journal of orthopaedic research
- Issue:
- Volume 40:Issue 12(2022)
- Issue Display:
- Volume 40, Issue 12 (2022)
- Year:
- 2022
- Volume:
- 40
- Issue:
- 12
- Issue Sort Value:
- 2022-0040-0012-0000
- Page Start:
- 2813
- Page End:
- 2821
- Publication Date:
- 2022-03-10
- Subjects:
- buttress thread -- fixation stability -- lateral migration resistance -- nonlocking cancellous screw -- pullout strength -- undercut thread
Orthopedics -- Periodicals
Musculoskeletal system -- Periodicals
616.7 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jor.25305 ↗
- Languages:
- English
- ISSNs:
- 0736-0266
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5027.665000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: