Detection rates of colorectal neoplasia during colonoscopies and their associated factors in the SCREESCO study. Issue 11 (9th September 2022)
- Record Type:
- Journal Article
- Title:
- Detection rates of colorectal neoplasia during colonoscopies and their associated factors in the SCREESCO study. Issue 11 (9th September 2022)
- Main Title:
- Detection rates of colorectal neoplasia during colonoscopies and their associated factors in the SCREESCO study
- Authors:
- Sekiguchi, Masau
Westerberg, Marcus
Ekbom, Anders
Hultcrantz, Rolf
Forsberg, Anna - Abstract:
- Abstract: Background and Aim: Colonoscopy quality, including lesion detectability, is variable, and factors influencing lesion detection are not fully understood. This study investigated lesion detection rates during colonoscopies and the associated factors in the SCREEning of Swedish COlons (SCREESCO) study. Methods: In this cross‐sectional analysis of data from SCREESCO, a large‐scale randomized controlled trial of colorectal cancer screening in the Swedish population aged 60 years, we assessed data of first‐time colonoscopies performed in both colonoscopy and fecal immunochemical test (FIT) arms. Results: This study included 16 552 individuals. The adenoma detection rate was 23.9% and 37.8% in colonoscopy and FIT arms, respectively. Regarding colonoscopy procedures, a withdrawal time ≥ 6 min was associated with higher detection rates of advanced adenomas (adjusted odds ratio [AOR] 2.474, 95% confidence interval [CI] 1.295–4.723), adenomas (2.181, 1.515–3.140), and proximal serrated lesions (pSLs) (1.713, 1.007–2.915). Antispasmodic use was associated with higher detection rates of these lesions and sessile serrated lesions (SSLs) (AOR, 95% CI: 1.523, 1.295–1.791; 1.361, 1.217–1.522; 1.450, 1.247–1.687; and 1.810, 1.512–2.167, respectively). Insertion time > 20 min was related to lower detection rates of adenomas, pSLs, and SSLs (AOR, 95% CI: 0.753, 0.639–0.887; 0.640, 0.495–0.828; and 0.704, 0.518–0.955, respectively). The relationship between a recent period and higherAbstract: Background and Aim: Colonoscopy quality, including lesion detectability, is variable, and factors influencing lesion detection are not fully understood. This study investigated lesion detection rates during colonoscopies and the associated factors in the SCREEning of Swedish COlons (SCREESCO) study. Methods: In this cross‐sectional analysis of data from SCREESCO, a large‐scale randomized controlled trial of colorectal cancer screening in the Swedish population aged 60 years, we assessed data of first‐time colonoscopies performed in both colonoscopy and fecal immunochemical test (FIT) arms. Results: This study included 16 552 individuals. The adenoma detection rate was 23.9% and 37.8% in colonoscopy and FIT arms, respectively. Regarding colonoscopy procedures, a withdrawal time ≥ 6 min was associated with higher detection rates of advanced adenomas (adjusted odds ratio [AOR] 2.474, 95% confidence interval [CI] 1.295–4.723), adenomas (2.181, 1.515–3.140), and proximal serrated lesions (pSLs) (1.713, 1.007–2.915). Antispasmodic use was associated with higher detection rates of these lesions and sessile serrated lesions (SSLs) (AOR, 95% CI: 1.523, 1.295–1.791; 1.361, 1.217–1.522; 1.450, 1.247–1.687; and 1.810, 1.512–2.167, respectively). Insertion time > 20 min was related to lower detection rates of adenomas, pSLs, and SSLs (AOR, 95% CI: 0.753, 0.639–0.887; 0.640, 0.495–0.828; and 0.704, 0.518–0.955, respectively). The relationship between a recent period and higher detection rates of pSLs and SSLs was also demonstrated. Conclusion: Lesion detectability in SCREESCO was mostly acceptable with room for improvement. In addition to sufficient withdrawal time, antispasmodic use and acquiring skills enabling short insertion time may improve lesion detection. Trial registration: ClinicalTrials.gov, ID: NCT02078804. … (more)
- Is Part Of:
- Journal of gastroenterology and hepatology. Volume 37:Issue 11(2022)
- Journal:
- Journal of gastroenterology and hepatology
- Issue:
- Volume 37:Issue 11(2022)
- Issue Display:
- Volume 37, Issue 11 (2022)
- Year:
- 2022
- Volume:
- 37
- Issue:
- 11
- Issue Sort Value:
- 2022-0037-0011-0000
- Page Start:
- 2120
- Page End:
- 2130
- Publication Date:
- 2022-09-09
- Subjects:
- adenoma detection rate -- antispasmodic -- colonoscopy -- colorectal cancer screening -- fecal immunochemical test
Gastroenterology -- Periodicals
Digestive organs -- Diseases -- Periodicals
Liver -- Diseases -- Periodicals
Gastroenterology -- Periodicals
Liver Diseases -- Periodicals
616.33 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1440-1746 ↗
http://onlinelibrary.wiley.com/ ↗
http://www.blackwell-synergy.com/loi/jgh ↗ - DOI:
- 10.1111/jgh.15990 ↗
- Languages:
- English
- ISSNs:
- 0815-9319
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4987.615000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24358.xml