Examining the efficacy and safety of endobiliary radiofrequency ablation for ingrowth occlusion after metal stent placement using a bovine model. (31st December 2022)
- Record Type:
- Journal Article
- Title:
- Examining the efficacy and safety of endobiliary radiofrequency ablation for ingrowth occlusion after metal stent placement using a bovine model. (31st December 2022)
- Main Title:
- Examining the efficacy and safety of endobiliary radiofrequency ablation for ingrowth occlusion after metal stent placement using a bovine model
- Authors:
- Inoue, Tadahisa
Kutsumi, Hiromu
Ibusuki, Mayu
Yoneda, Masashi - Abstract:
- Abstract: Background: Although endobiliary radiofrequency ablation (RFA) may be an option for the treatment of ingrowth occlusion after self-expandable metal stent (SEMS) deployment, its utility remains uncertain. This study aimed to clarify its utility and safety using bovine liver. Methods: A prototype multifunctional RFA catheter and conventional uncovered SEMS were employed in this experimental study. We devised three model types: the ingrowth-ablation, ingrowth-ablation with stent-wire contact (created such that the electrodes were in contact with the metal stent-wire), and standard-ablation models (control). The study outcome was the ablation depth associated with RFA, which was compared among the three models. Results: Thirty-six ablation procedures were conducted (12 for each of the 3 models). In the unipolar mode, the median ablation depth with the stent-wire contact model (1.0 mm) was significantly lower than that of the ingrowth-ablation (2.0 mm, p = 0.005) and standard-ablation models (2.3 mm, p = 0.004). There was no significant difference between the ingrowth-ablation and standard-ablation models ( p = 0.563). In the bipolar mode, the median ablation depth with the stent-wire contact model (1.0 mm) was also significantly lower than that of the ingrowth-ablation (2.1 mm, p = 0.008) and standard-ablation models (2.0 mm, p = 0.011), and there was no significant difference between the ingrowth-ablation and standard-ablation models ( p = 0.807). ScorchingAbstract: Background: Although endobiliary radiofrequency ablation (RFA) may be an option for the treatment of ingrowth occlusion after self-expandable metal stent (SEMS) deployment, its utility remains uncertain. This study aimed to clarify its utility and safety using bovine liver. Methods: A prototype multifunctional RFA catheter and conventional uncovered SEMS were employed in this experimental study. We devised three model types: the ingrowth-ablation, ingrowth-ablation with stent-wire contact (created such that the electrodes were in contact with the metal stent-wire), and standard-ablation models (control). The study outcome was the ablation depth associated with RFA, which was compared among the three models. Results: Thirty-six ablation procedures were conducted (12 for each of the 3 models). In the unipolar mode, the median ablation depth with the stent-wire contact model (1.0 mm) was significantly lower than that of the ingrowth-ablation (2.0 mm, p = 0.005) and standard-ablation models (2.3 mm, p = 0.004). There was no significant difference between the ingrowth-ablation and standard-ablation models ( p = 0.563). In the bipolar mode, the median ablation depth with the stent-wire contact model (1.0 mm) was also significantly lower than that of the ingrowth-ablation (2.1 mm, p = 0.008) and standard-ablation models (2.0 mm, p = 0.011), and there was no significant difference between the ingrowth-ablation and standard-ablation models ( p = 0.807). Scorching around the stent-wire was not observed in any specimen. Conclusions: In this ex vivo study, endobiliary RFA for ingrowth occlusion can be considered a useful modality, but the ablation effect is diminished when the electrode comes into contact with the stent-wire. … (more)
- Is Part Of:
- International journal of hyperthermia. Volume 39:Number 1(2022)
- Journal:
- International journal of hyperthermia
- Issue:
- Volume 39:Number 1(2022)
- Issue Display:
- Volume 39, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 39
- Issue:
- 1
- Issue Sort Value:
- 2022-0039-0001-0000
- Page Start:
- 1415
- Page End:
- 1420
- Publication Date:
- 2022-12-31
- Subjects:
- Radiofrequency ablation -- ingrowth -- metal stent -- malignant biliary stricture; reintervention
Thermotherapy -- Periodicals
615.832 - Journal URLs:
- http://informahealthcare.com/loi/hth ↗
http://www.tandf.co.uk/journals/titles/02656736.asp ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/02656736.2022.2146212 ↗
- Languages:
- English
- ISSNs:
- 0265-6736
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.297000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 24352.xml