MO769COMPARISON OF HEMODIALYSIS CONNECTORS CAPS VS ANTIMICROIAL BARRIER CAPS IN CENTERAL LINE-ASSOICATED BLOOSTREAM INFECTION RATES FOR HEMODIALYSIS PATIENTS. (29th May 2021)
- Record Type:
- Journal Article
- Title:
- MO769COMPARISON OF HEMODIALYSIS CONNECTORS CAPS VS ANTIMICROIAL BARRIER CAPS IN CENTERAL LINE-ASSOICATED BLOOSTREAM INFECTION RATES FOR HEMODIALYSIS PATIENTS. (29th May 2021)
- Main Title:
- MO769COMPARISON OF HEMODIALYSIS CONNECTORS CAPS VS ANTIMICROIAL BARRIER CAPS IN CENTERAL LINE-ASSOICATED BLOOSTREAM INFECTION RATES FOR HEMODIALYSIS PATIENTS
- Authors:
- Hemeyer, Connie
Moreland, Marshall
Olson, Elsa
Fitzpatrick, Peter
Hickson, Latonya - Abstract:
- Abstract: Background and Aims: Central line-associated bloodstream infections (CLABSI) lead to increased morbidity and mortality in hemodialysis-dependent patients and are costly to treat. Devices such as hemodialysis connector caps (Tego) and antimicrobial barrier caps (ClearGuardHD) represent promising interventions to reduce CLABSIs. The aim of this study was to assess the efficacy of these devices in reducing CLABSIs in hemodialysis patients who use tunneled dialysis catheters at outpatient dialysis units in a healthcare system. Method: In a retrospective review of a quality improvement project, we compared cumulative 6-month CLABSI infection rates before and after transition from Tego connectors to ClearGuardHD caps. CLABSI events, reported to National Healthcare Safety Network (NHSN), were expressed as CLABSI events per 100 patient-months. All adult patients (age >18 years) receiving hemodialysis via a tunneled central catheter were included in the study from February 2018-August 2020. The study cohort was comprised of 13 outpatient dialysis units in a healthcare system with locations throughout the Northern Midwest and Southeastern United States. The date of change from Tego to ClearGuardHD was phased throughout the different units over the study period with events recorded 6 months pre- and post-intervention. Patients receiving home dialysis therapies were excluded from the study. Results: The cumulative 6-month CLABSI event rate decreased by 75.7%; Tego (0.465/100Abstract: Background and Aims: Central line-associated bloodstream infections (CLABSI) lead to increased morbidity and mortality in hemodialysis-dependent patients and are costly to treat. Devices such as hemodialysis connector caps (Tego) and antimicrobial barrier caps (ClearGuardHD) represent promising interventions to reduce CLABSIs. The aim of this study was to assess the efficacy of these devices in reducing CLABSIs in hemodialysis patients who use tunneled dialysis catheters at outpatient dialysis units in a healthcare system. Method: In a retrospective review of a quality improvement project, we compared cumulative 6-month CLABSI infection rates before and after transition from Tego connectors to ClearGuardHD caps. CLABSI events, reported to National Healthcare Safety Network (NHSN), were expressed as CLABSI events per 100 patient-months. All adult patients (age >18 years) receiving hemodialysis via a tunneled central catheter were included in the study from February 2018-August 2020. The study cohort was comprised of 13 outpatient dialysis units in a healthcare system with locations throughout the Northern Midwest and Southeastern United States. The date of change from Tego to ClearGuardHD was phased throughout the different units over the study period with events recorded 6 months pre- and post-intervention. Patients receiving home dialysis therapies were excluded from the study. Results: The cumulative 6-month CLABSI event rate decreased by 75.7%; Tego (0.465/100 patient-months) vs. ClearGuardHD caps (0.113/100 patient-months). A total of 17 CLABSI occurrences were reported within 3, 654 patient-months with Tego use. However, only 4 CLABSI occurrences were reported within 3, 527 patient-months during ClearGuardHD use. Conclusion: ClearGuardHD caps reduced the rate of CLABSI among hemodialysis patients and are superior to Tego connectors. These findings support prior studies. Implementation of ClearGuardHD caps may help eliminate CLABSI-associated morbidity among individuals requiring maintenance hemodialysis therapy. … (more)
- Is Part Of:
- Nephrology dialysis transplantation. Volume 36(2021)Supplement 1
- Journal:
- Nephrology dialysis transplantation
- Issue:
- Volume 36(2021)Supplement 1
- Issue Display:
- Volume 36, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 36
- Issue:
- 1
- Issue Sort Value:
- 2021-0036-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-05-29
- Subjects:
- Nephrology -- Periodicals
Hemodialysis -- Periodicals
Kidneys -- Transplantation -- Periodicals
Hemodialysis
Kidneys -- Transplantation
Nephrology
Periodicals
616.61 - Journal URLs:
- http://ndt.oxfordjournals.org/ ↗
http://www.oup.co.uk/ndt/ ↗
http://ukcatalogue.oup.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0931-0509;screen=info;ECOIP ↗ - DOI:
- 10.1093/ndt/gfab103.007 ↗
- Languages:
- English
- ISSNs:
- 0931-0509
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6075.685300
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24346.xml