MO676COMPLEMENT ACTIVATION BY DIALYSIS MEMBRANES AND ITS ASSOCIATION WITH SECONDARY MEMBRANE FORMATION AND SURFACE CHARGE. (29th May 2021)
- Record Type:
- Journal Article
- Title:
- MO676COMPLEMENT ACTIVATION BY DIALYSIS MEMBRANES AND ITS ASSOCIATION WITH SECONDARY MEMBRANE FORMATION AND SURFACE CHARGE. (29th May 2021)
- Main Title:
- MO676COMPLEMENT ACTIVATION BY DIALYSIS MEMBRANES AND ITS ASSOCIATION WITH SECONDARY MEMBRANE FORMATION AND SURFACE CHARGE
- Authors:
- Melchior, Pascal
Erlenkötter, Ansgar
Zawada, Adam
Delinski, Dirk
Schall, Christian
Stauss-Grabo, Manuela
Kennedy, James - Abstract:
- Abstract: Background and Aims: Activation of the complement system may occur during blood-membrane interactions in hemodialysis and contribute to chronic inflammation of patients with end-stage renal disease (ESRD). Hydrophilic modification with polyvinylpyrrolidone (PVP) has been suggested to increase the biocompatibility profile of dialysis membranes. In the present study we compared complement activation of synthetic and cellulose-based membranes, including the polysulfone membrane with α-tocopherol-stabilized, PVP-enriched inner surface of the novel FX CorAL dialyzer, and linked the results to their physical characteristics. Method: Eight synthetic and cellulose-based dialyzers (FX CorAL, FX CorDiax [Fresenius Medical Care]; Polyflux, THERANOVA [Baxter]; ELISIO, SUREFLUX [Nipro]; xevonta [B. Braun]; FDX [Nikkisio Medical]) were investigated in the present study. Complement activation (C3a, C5a, sC5b-9) was evaluated in a 3h ex vivo recirculation model with human blood. Albumin sieving coefficients were determined over a 4h ex vivo recirculation model with human plasma as a surrogate of secondary membrane formation. Zeta potential was measured as an indicator for the surface charge of the membranes. Results: The FX CorAL dialyzer induced the lowest activation of the three complement factors (C3a: -39.4%; C5a: -57.5%; sC5b-9: -58.9% compared to the reference). Highest complement activation was found for the cellulose-based SUREFLUX (C3a: +154.0%) and the FDX (C5a: +335.0%;Abstract: Background and Aims: Activation of the complement system may occur during blood-membrane interactions in hemodialysis and contribute to chronic inflammation of patients with end-stage renal disease (ESRD). Hydrophilic modification with polyvinylpyrrolidone (PVP) has been suggested to increase the biocompatibility profile of dialysis membranes. In the present study we compared complement activation of synthetic and cellulose-based membranes, including the polysulfone membrane with α-tocopherol-stabilized, PVP-enriched inner surface of the novel FX CorAL dialyzer, and linked the results to their physical characteristics. Method: Eight synthetic and cellulose-based dialyzers (FX CorAL, FX CorDiax [Fresenius Medical Care]; Polyflux, THERANOVA [Baxter]; ELISIO, SUREFLUX [Nipro]; xevonta [B. Braun]; FDX [Nikkisio Medical]) were investigated in the present study. Complement activation (C3a, C5a, sC5b-9) was evaluated in a 3h ex vivo recirculation model with human blood. Albumin sieving coefficients were determined over a 4h ex vivo recirculation model with human plasma as a surrogate of secondary membrane formation. Zeta potential was measured as an indicator for the surface charge of the membranes. Results: The FX CorAL dialyzer induced the lowest activation of the three complement factors (C3a: -39.4%; C5a: -57.5%; sC5b-9: -58.9% compared to the reference). Highest complement activation was found for the cellulose-based SUREFLUX (C3a: +154.0%) and the FDX (C5a: +335.0%; sC5b-9: +287.9%) dialyzers. Moreover, the FX CorAL dialyzer had the nearest-to-neutral zeta potential (-2.38 mV) and the lowest albumin sieving coefficient decrease over time. Albumin sieving coefficient decrease was associated with complement activation by the investigated dialyzers. Conclusion: Our present results indicate that the surface modification implemented in the FX CorAL dialyzer reduces secondary membrane formation and improves the biocompatibility profile. Further clinical studies are needed to investigate whether these observations will result in a lower inflammatory burden of hemodialysis patients. … (more)
- Is Part Of:
- Nephrology dialysis transplantation. Volume 36(2021)Supplement 1
- Journal:
- Nephrology dialysis transplantation
- Issue:
- Volume 36(2021)Supplement 1
- Issue Display:
- Volume 36, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 36
- Issue:
- 1
- Issue Sort Value:
- 2021-0036-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-05-29
- Subjects:
- Nephrology -- Periodicals
Hemodialysis -- Periodicals
Kidneys -- Transplantation -- Periodicals
Hemodialysis
Kidneys -- Transplantation
Nephrology
Periodicals
616.61 - Journal URLs:
- http://ndt.oxfordjournals.org/ ↗
http://www.oup.co.uk/ndt/ ↗
http://ukcatalogue.oup.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0931-0509;screen=info;ECOIP ↗ - DOI:
- 10.1093/ndt/gfab099.0021 ↗
- Languages:
- English
- ISSNs:
- 0931-0509
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6075.685300
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24345.xml