Individual heterogeneity and airborne infection: Effect of non-uniform air distribution. (December 2022)
- Record Type:
- Journal Article
- Title:
- Individual heterogeneity and airborne infection: Effect of non-uniform air distribution. (December 2022)
- Main Title:
- Individual heterogeneity and airborne infection: Effect of non-uniform air distribution
- Authors:
- Jia, Wei
Cheng, Pan
Ma, Luping
Wang, Shengqi
Qian, Hua
Li, Yuguo - Abstract:
- Abstract: The classical Wells–Riley equation assumes homogeneity of susceptible individuals and environments to airborne exposure. However, individual susceptibility to infection is mostly heterogeneous, and exposure variability could arise from differences in inhalation rate, spatiotemporal non-uniformity of infectious aerosol concentrations, and the exposure trajectory and time. Non-uniform air distribution results in spatial non-uniformity of infectious aerosol concentrations. The non-uniformity effect is essentially a problem of individual infection probability. Here, we derived a general dose-response equation and a heterogeneous Wells–Riley equation accounting for individual variability in infection probability. The heterogeneous Wells-Riley equation shows the potential of the zone air distribution effectiveness to consider spatial non-uniformity under steady-state conditions. An existing quanta generation rate formula was theoretically justified. The new equation was then applied to a restaurant reporting an outbreak of coronavirus disease 2019, with spatial and/or temporal heterogeneity of infectious aerosol concentrations. Our results show the need to include spatial non-uniformity in outbreak investigations. A hypothetical two-zone setup was used to demonstrate how the inter-zonal distribution of clean air and the inter-zonal exchange flow affect airborne infections. An infector in a poorly diluted zone with the greatest number of susceptible individuals wouldAbstract: The classical Wells–Riley equation assumes homogeneity of susceptible individuals and environments to airborne exposure. However, individual susceptibility to infection is mostly heterogeneous, and exposure variability could arise from differences in inhalation rate, spatiotemporal non-uniformity of infectious aerosol concentrations, and the exposure trajectory and time. Non-uniform air distribution results in spatial non-uniformity of infectious aerosol concentrations. The non-uniformity effect is essentially a problem of individual infection probability. Here, we derived a general dose-response equation and a heterogeneous Wells–Riley equation accounting for individual variability in infection probability. The heterogeneous Wells-Riley equation shows the potential of the zone air distribution effectiveness to consider spatial non-uniformity under steady-state conditions. An existing quanta generation rate formula was theoretically justified. The new equation was then applied to a restaurant reporting an outbreak of coronavirus disease 2019, with spatial and/or temporal heterogeneity of infectious aerosol concentrations. Our results show the need to include spatial non-uniformity in outbreak investigations. A hypothetical two-zone setup was used to demonstrate how the inter-zonal distribution of clean air and the inter-zonal exchange flow affect airborne infections. An infector in a poorly diluted zone with the greatest number of susceptible individuals would result in the most secondary infections, whereas an infector in a well-ventilated zone with few susceptible individuals would result in the least secondary infections. Graphical abstract: Image 1 Highlights: The individual inhalation probability of a virion in space was estimated. A new Wells–Riley equation was developed to determine individual infection probability. Spatial non-uniformity of clean air was found to significantly affect airborne infections. The zone air distribution effectiveness in the ASHRAE standard was linked to airborne infection risk. Outbreak investigations should consider airflow non-uniformity. … (more)
- Is Part Of:
- Building and environment. Volume 226(2022)
- Journal:
- Building and environment
- Issue:
- Volume 226(2022)
- Issue Display:
- Volume 226, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 226
- Issue:
- 2022
- Issue Sort Value:
- 2022-0226-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-12
- Subjects:
- Effective dilution air -- Intake fraction time -- Poisson-binomial distribution -- Wells–Riley equation -- SARS-CoV-2 transmission
Buildings -- Environmental engineering -- Periodicals
Building -- Research -- Periodicals
Constructions -- Technique de l'environnement -- Périodiques
Electronic journals
696 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03601323 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.buildenv.2022.109674 ↗
- Languages:
- English
- ISSNs:
- 0360-1323
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2359.355000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24344.xml