An analytic model to calculate voxel s-values for 177Lu. (1st November 2022)
- Record Type:
- Journal Article
- Title:
- An analytic model to calculate voxel s-values for 177Lu. (1st November 2022)
- Main Title:
- An analytic model to calculate voxel s-values for 177Lu
- Authors:
- Pistone, Daniele
Auditore, Lucrezia
Italiano, Antonio
Baldari, Sergio
Amato, Ernesto - Abstract:
- Abstract: Objective . 177 Lu is one of the most employed isotopes in targeted radionuclide therapies and theranostics, and 3D internal dosimetry for such procedures has great importance. Voxel S-Values (VSVs) approach is widely used for this purpose, but VSVs are available for a limited number of voxel dimensions. The aim of this work is to develop an analytic model for the calculation of 177 Lu-VSVs in any cubic voxelized geometry of practical interest. Approach . Monte Carlo (MC) simulations were implemented with the toolkit GAMOS to evaluate VSVs in voxelized geometries of soft tissue from a source of 177 Lu homogeneously distributed in the central voxel. Nine geometric setups, containing 15 × 15 × 15 cubic voxels of sides l ranging from 2 mm to 6 mm, in steps of 0.5 mm, were considered. For each l, the VSVs computed as a function of the 'normalized radius', R n = R/l (with R = distance from the center of the source voxel), were fitted with a parametric function. The dependencies of the parameters as a function of l were then fitted with appropriate functions, in order to implement the model for deducing 177 Lu-VSVs for any l within the aforementioned range. Main results . The MC-derived VSVs were satisfactorily compared with literature data for validation, and the VSVs computed with the analytic model agree with the MC ones within 2% for R n ≤ 2 and within 6% for R n > 2. Significance . The proposed model enables the easy and fast calculation, with a simpleAbstract: Objective . 177 Lu is one of the most employed isotopes in targeted radionuclide therapies and theranostics, and 3D internal dosimetry for such procedures has great importance. Voxel S-Values (VSVs) approach is widely used for this purpose, but VSVs are available for a limited number of voxel dimensions. The aim of this work is to develop an analytic model for the calculation of 177 Lu-VSVs in any cubic voxelized geometry of practical interest. Approach . Monte Carlo (MC) simulations were implemented with the toolkit GAMOS to evaluate VSVs in voxelized geometries of soft tissue from a source of 177 Lu homogeneously distributed in the central voxel. Nine geometric setups, containing 15 × 15 × 15 cubic voxels of sides l ranging from 2 mm to 6 mm, in steps of 0.5 mm, were considered. For each l, the VSVs computed as a function of the 'normalized radius', R n = R/l (with R = distance from the center of the source voxel), were fitted with a parametric function. The dependencies of the parameters as a function of l were then fitted with appropriate functions, in order to implement the model for deducing 177 Lu-VSVs for any l within the aforementioned range. Main results . The MC-derived VSVs were satisfactorily compared with literature data for validation, and the VSVs computed with the analytic model agree with the MC ones within 2% for R n ≤ 2 and within 6% for R n > 2. Significance . The proposed model enables the easy and fast calculation, with a simple spreadsheet, of 177 Lu-VSVs in any cubic voxelized geometry of practical interest, avoiding the necessity of implementing ad-hoc MC simulations to estimate VSVs for specific voxel dimensions not available in literature data. … (more)
- Is Part Of:
- Biomedical physics & engineering express. Volume 8:Number 6(2022)
- Journal:
- Biomedical physics & engineering express
- Issue:
- Volume 8:Number 6(2022)
- Issue Display:
- Volume 8, Issue 6 (2022)
- Year:
- 2022
- Volume:
- 8
- Issue:
- 6
- Issue Sort Value:
- 2022-0008-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-11-01
- Subjects:
- Lutetium-177 -- voxel S-values -- internal dosimetry -- monte carlo -- GAMOS
Medical physics -- Periodicals
Biophysics -- Periodicals
Biomedical engineering -- Periodicals
Medical sciences -- Periodicals
610.153 - Journal URLs:
- http://iopscience.iop.org/2057-1976/ ↗
http://www.iop.org/ ↗ - DOI:
- 10.1088/2057-1976/ac997e ↗
- Languages:
- English
- ISSNs:
- 2057-1976
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 24323.xml