Cost-efficient anthropomorphic head phantom for quantitative image quality assessment in cone beam CT. (1st November 2022)
- Record Type:
- Journal Article
- Title:
- Cost-efficient anthropomorphic head phantom for quantitative image quality assessment in cone beam CT. (1st November 2022)
- Main Title:
- Cost-efficient anthropomorphic head phantom for quantitative image quality assessment in cone beam CT
- Authors:
- Wang, Yichao
Dankelman, Jenny
Ruijters, Danny - Abstract:
- Abstract: In this study, a novel anthropomorphic head phantom for quantitative image quality assessment in cone beam computed tomography (CBCT) is proposed. The phantom is composed of tissue equivalent materials (TEMs) which are suitable for cost-efficient fabrication methods such as silicone casting and 3D printing. A monocalcium phosphate/gypsum mixture (MCPHG), nylon and a silyl modified polymer gel (SMP) are proposed as bone, muscle and brain equivalent materials respectively. The TEMs were evaluated for their radiodensity in terms of Hounsfield Units (HU) and their x-ray scatter characteristics. The median radiodensity and inter quartile range (IQR) of the MCPHG and SMP were found to be within the range of the theoretical radiodensity for bone and brain tissue: 922 (IQR = 156) and 47 (IQR = 7) HU respectively. The median radiodensity of nylon was slightly outside of the HU range of muscle tissue, but within the HU range of a combination of muscle and adipose tissue: −18 (IQR = 40) HU. The median ratios between the measured scatter characteristics and simulated tissues were between 0.84 and 1.13 (IQR between 0.05 and 0.14). The preliminary results of this study show that the proposed design and TEMs are potentially suitable for the fabrication of a cost-efficient anthropomorphic head phantom for quantitative image quality assessment in CT or CBCT.
- Is Part Of:
- Biomedical physics & engineering express. Volume 8:Number 6(2022)
- Journal:
- Biomedical physics & engineering express
- Issue:
- Volume 8:Number 6(2022)
- Issue Display:
- Volume 8, Issue 6 (2022)
- Year:
- 2022
- Volume:
- 8
- Issue:
- 6
- Issue Sort Value:
- 2022-0008-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-11-01
- Subjects:
- anthropomorphic head phantom -- cone beam computed tomography -- image quality assessment -- radiodensity -- scatter -- tissue equivalent materials
Medical physics -- Periodicals
Biophysics -- Periodicals
Biomedical engineering -- Periodicals
Medical sciences -- Periodicals
610.153 - Journal URLs:
- http://iopscience.iop.org/2057-1976/ ↗
http://www.iop.org/ ↗ - DOI:
- 10.1088/2057-1976/aca02d ↗
- Languages:
- English
- ISSNs:
- 2057-1976
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 24323.xml