Clinical assessment of geometric distortion for a 0.35T MR‐guided radiotherapy system. Issue 8 (7th July 2021)
- Record Type:
- Journal Article
- Title:
- Clinical assessment of geometric distortion for a 0.35T MR‐guided radiotherapy system. Issue 8 (7th July 2021)
- Main Title:
- Clinical assessment of geometric distortion for a 0.35T MR‐guided radiotherapy system
- Authors:
- Neylon, John
Cook, Kiri A.
Yang, Yingli
Du, Dongsu
Sheng, Ke
Chin, Robert K.
Kishan, Amar U.
Lamb, James M.
Low, Daniel A.
Cao, Minsong - Abstract:
- Abstract: Purpose: To estimate the overall spatial distortion on clinical patient images for a 0.35 T MR‐guided radiotherapy system. Methods: Ten patients with head‐and‐neck cancer underwent CT and MR simulations with identical immobilization. The MR images underwent the standard systematic distortion correction post‐processing. The images were rigidly registered and landmark‐based analysis was performed by an anatomical expert. Distortion was quantified using Euclidean distance between each landmark pair and tagged by tissue interface: bone‐tissue, soft tissue, or air‐tissue. For baseline comparisons, an anthropomorphic phantom was imaged and analyzed. Results: The average spatial discrepancy between CT and MR landmarks was 1.15 ± 1.14 mm for the phantom and 1.46 ± 1.78 mm for patients. The error histogram peaked at 0–1 mm. 66% of the discrepancies were <2 mm and 51% <1 mm. In the patient data, statistically significant differences ( p ‐values < 0.0001) were found between the different tissue interfaces with averages of 0.88 ± 1.24 mm, 2.01 ± 2.20 mm, and 1.41 ± 1.56 mm for the air/tissue, bone/tissue, and soft tissue, respectively. The distortion generally correlated with the in‐plane radial distance from the image center along the longitudinal axis of the MR. Conclusion: Spatial distortion remains in the MR images after systematic distortion corrections. Although the average errors were relatively small, large distortions observed at bone/tissue interfaces emphasize theAbstract: Purpose: To estimate the overall spatial distortion on clinical patient images for a 0.35 T MR‐guided radiotherapy system. Methods: Ten patients with head‐and‐neck cancer underwent CT and MR simulations with identical immobilization. The MR images underwent the standard systematic distortion correction post‐processing. The images were rigidly registered and landmark‐based analysis was performed by an anatomical expert. Distortion was quantified using Euclidean distance between each landmark pair and tagged by tissue interface: bone‐tissue, soft tissue, or air‐tissue. For baseline comparisons, an anthropomorphic phantom was imaged and analyzed. Results: The average spatial discrepancy between CT and MR landmarks was 1.15 ± 1.14 mm for the phantom and 1.46 ± 1.78 mm for patients. The error histogram peaked at 0–1 mm. 66% of the discrepancies were <2 mm and 51% <1 mm. In the patient data, statistically significant differences ( p ‐values < 0.0001) were found between the different tissue interfaces with averages of 0.88 ± 1.24 mm, 2.01 ± 2.20 mm, and 1.41 ± 1.56 mm for the air/tissue, bone/tissue, and soft tissue, respectively. The distortion generally correlated with the in‐plane radial distance from the image center along the longitudinal axis of the MR. Conclusion: Spatial distortion remains in the MR images after systematic distortion corrections. Although the average errors were relatively small, large distortions observed at bone/tissue interfaces emphasize the need for quantitative methods for assessing and correcting patient‐specific spatial distortions. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 22:Issue 8(2021)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 22:Issue 8(2021)
- Issue Display:
- Volume 22, Issue 8 (2021)
- Year:
- 2021
- Volume:
- 22
- Issue:
- 8
- Issue Sort Value:
- 2021-0022-0008-0000
- Page Start:
- 303
- Page End:
- 309
- Publication Date:
- 2021-07-07
- Subjects:
- geometric distortion -- MRgRT -- MR‐guided radiotherapy -- patient‐specific distortion
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.13340 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24285.xml