A T1‐based correction method for proton resonance frequency shift thermometry in breast tissue. Issue 9 (6th August 2021)
- Record Type:
- Journal Article
- Title:
- A T1‐based correction method for proton resonance frequency shift thermometry in breast tissue. Issue 9 (6th August 2021)
- Main Title:
- A T1‐based correction method for proton resonance frequency shift thermometry in breast tissue
- Authors:
- McLean, McKenzie
Parker, Dennis L.
Odéen, Henrik
Payne, Allison - Abstract:
- Abstract: Purpose: Develop and evaluate the effectiveness of a T1‐based correction method for errors in proton resonant frequency shift thermometry due to non‐local field effects caused by heating in fatty breast tissues. Methods: Computational models of human breast tissue were created by segmenting MRI data from a healthy human volunteer. MR‐guided focused ultrasound (MRgFUS) heating and MR thermometry measurements were simulated in several locations in the heterogeneous segmented breast models. A T1‐based correction method for PRF thermometry errors was applied and the maximum positive and negative errors and the root mean squared error (RMSE) in a region around each heating location was evaluated with and without correction. The method uses T1 measurements to estimate the temperature change in fatty tissues and correct for their influence. Experimental data from a heating study in cadaver breast tissue were analyzed, and the expected PRFS error computed. Results: The simulated MR thermometry had maximum single voxel errors ranging between 10% and 18% when no correction was applied. Applying the correction led to a considerable improvement, lowering the maximum error range to 2%–5%. The 5th to 95th percentile interval of the temperature error distribution was also lowered with correction, from approximately 3.5 to 1°C. This correction worked even when T1 times were uniformly raised or lowered by 5%–10%. The experimental data showed predicted errors of 15%. Conclusions:Abstract: Purpose: Develop and evaluate the effectiveness of a T1‐based correction method for errors in proton resonant frequency shift thermometry due to non‐local field effects caused by heating in fatty breast tissues. Methods: Computational models of human breast tissue were created by segmenting MRI data from a healthy human volunteer. MR‐guided focused ultrasound (MRgFUS) heating and MR thermometry measurements were simulated in several locations in the heterogeneous segmented breast models. A T1‐based correction method for PRF thermometry errors was applied and the maximum positive and negative errors and the root mean squared error (RMSE) in a region around each heating location was evaluated with and without correction. The method uses T1 measurements to estimate the temperature change in fatty tissues and correct for their influence. Experimental data from a heating study in cadaver breast tissue were analyzed, and the expected PRFS error computed. Results: The simulated MR thermometry had maximum single voxel errors ranging between 10% and 18% when no correction was applied. Applying the correction led to a considerable improvement, lowering the maximum error range to 2%–5%. The 5th to 95th percentile interval of the temperature error distribution was also lowered with correction, from approximately 3.5 to 1°C. This correction worked even when T1 times were uniformly raised or lowered by 5%–10%. The experimental data showed predicted errors of 15%. Conclusions: This simulation study demonstrates that the T1‐based correction method reduces MR thermometry errors due to non‐local effects from heating in fatty tissues, potentially improving the accuracy of thermometry measurements during MRgFUS treatments. The presented correction method is reliant on having a patient‐specific 3D model of the breast, and may be limited by the accuracy of the fat temperatures which in turn may be limited by noise or bias present in the T1 measurements. … (more)
- Is Part Of:
- Medical physics. Volume 48:Issue 9(2021)
- Journal:
- Medical physics
- Issue:
- Volume 48:Issue 9(2021)
- Issue Display:
- Volume 48, Issue 9 (2021)
- Year:
- 2021
- Volume:
- 48
- Issue:
- 9
- Issue Sort Value:
- 2021-0048-0009-0000
- Page Start:
- 4719
- Page End:
- 4729
- Publication Date:
- 2021-08-06
- Subjects:
- magnetic resonance thermometry -- PRF -- T1 -- tumor ablation
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.15085 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24280.xml