Reduced Graphene Oxide‐Gold Nanoparticle Nanohybrid Modified Cost‐Effective Paper‐Based Biosensor for Procalcitonin Detection. Issue 41 (3rd November 2022)
- Record Type:
- Journal Article
- Title:
- Reduced Graphene Oxide‐Gold Nanoparticle Nanohybrid Modified Cost‐Effective Paper‐Based Biosensor for Procalcitonin Detection. Issue 41 (3rd November 2022)
- Main Title:
- Reduced Graphene Oxide‐Gold Nanoparticle Nanohybrid Modified Cost‐Effective Paper‐Based Biosensor for Procalcitonin Detection
- Authors:
- Gupta, Yachana
Pandey, Chandra Mouli
Ghrera, Aditya Sharma - Abstract:
- Abstract: The present study reports the fabrication of reduced graphene oxide (rGO)/gold nanoparticles (AuNP) nanocomposites modified cellulose fiber paper‐based electrochemical biosensor for procalcitonin (PCT) biomarker detection. PCT is a biomarker specific for bacterial infection (BI) detection and has gained much attention as a potential solution to the problems associated with determining appropriate antibiotic use. In sepsis and other severe infections, serum PCT levels increase to values above 100 ng mL −1 in response to pro‐inflammatory stimulation. The structural and morphological characterization of the rGO‐AuNP composite are investigated using UV‐Vis spectroscopy, FTIR spectroscopy, X‐ray diffraction, and scanning electron microscopy. Monoclonal antibodies specific to PCT were covalently immobilized onto the rGO‐AuNP nanocomposite modified paper to fabricate an electrochemical biosensor. The fabricated biosensor exhibits linearity in the PCT concentration range 10 −15×10 3 pg mL −1, with a low detection limit 10 pg mL −1 . Furthermore, the proposed biosensor also exhibited good selectivity and could detect PCT biomarkers even in the presence of other interfering electroactive species such as glucose, oxalic acid, and urea. The proposed CF‐based biosensor has been proven as an accelerated simple point‐of‐care (POC) exploratory approach for early PCT diagnosis in inadequate areas with limited production facilities, computational techniques, and highly skilledAbstract: The present study reports the fabrication of reduced graphene oxide (rGO)/gold nanoparticles (AuNP) nanocomposites modified cellulose fiber paper‐based electrochemical biosensor for procalcitonin (PCT) biomarker detection. PCT is a biomarker specific for bacterial infection (BI) detection and has gained much attention as a potential solution to the problems associated with determining appropriate antibiotic use. In sepsis and other severe infections, serum PCT levels increase to values above 100 ng mL −1 in response to pro‐inflammatory stimulation. The structural and morphological characterization of the rGO‐AuNP composite are investigated using UV‐Vis spectroscopy, FTIR spectroscopy, X‐ray diffraction, and scanning electron microscopy. Monoclonal antibodies specific to PCT were covalently immobilized onto the rGO‐AuNP nanocomposite modified paper to fabricate an electrochemical biosensor. The fabricated biosensor exhibits linearity in the PCT concentration range 10 −15×10 3 pg mL −1, with a low detection limit 10 pg mL −1 . Furthermore, the proposed biosensor also exhibited good selectivity and could detect PCT biomarkers even in the presence of other interfering electroactive species such as glucose, oxalic acid, and urea. The proposed CF‐based biosensor has been proven as an accelerated simple point‐of‐care (POC) exploratory approach for early PCT diagnosis in inadequate areas with limited production facilities, computational techniques, and highly skilled experts. Abstract : The figure is presenting modification of cellulose paper substrate with rGO‐AuNP composite modified are used for electrochemical studies and sensor development. … (more)
- Is Part Of:
- ChemistrySelect. Volume 7:Issue 41(2022)
- Journal:
- ChemistrySelect
- Issue:
- Volume 7:Issue 41(2022)
- Issue Display:
- Volume 7, Issue 41 (2022)
- Year:
- 2022
- Volume:
- 7
- Issue:
- 41
- Issue Sort Value:
- 2022-0007-0041-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2022-11-03
- Subjects:
- Chronoamperometry -- gold nanoparticles -- procalcitonin -- paper-based sensor -- reduced graphene oxide
Chemistry -- Periodicals
540.5 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2365-6549 ↗ - DOI:
- 10.1002/slct.202202642 ↗
- Languages:
- English
- ISSNs:
- 2365-6549
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3172.241000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24267.xml