Comparison of Long-Term Microscopic and Endoscopic Audiologic Results After Total Ossicular Replacement Prosthesis Surgery. Issue 10 (December 2022)
- Record Type:
- Journal Article
- Title:
- Comparison of Long-Term Microscopic and Endoscopic Audiologic Results After Total Ossicular Replacement Prosthesis Surgery. Issue 10 (December 2022)
- Main Title:
- Comparison of Long-Term Microscopic and Endoscopic Audiologic Results After Total Ossicular Replacement Prosthesis Surgery
- Authors:
- Baazil, Adrianus H.A.
Ebbens, Fenna A.
van Spronsen, Erik
De Wolf, Maarten J.F.
Dikkers, Frederik G. - Abstract:
- Abstract : Objective: To compare short-term and long-term outcomes after transcanal endoscope-assisted with microscope-assisted ossiculoplasty using the Fisch titanium total prosthesis (FTTP). Study Design: Retrospective chart review. Setting: Tertiary referral center. Patients: Pediatric (<18 yr of age) and adult patients undergoing ossiculoplasty with the FTTP between January 2016 and December 2019. Intervention: Transcanal endoscope-assisted (n = 30) or microscope-assisted (n = 76) ossiculoplasty with the FTTP. In the microscopic group, 48 were performed through the ear canal and 28 by retroauricular approach. Main Outcome Measure: Short-term (3 mo) and long-term (average 20.2 mo) PTA0.5-2kHz air and bone conduction thresholds were evaluated. Results: In total, 106 patients were included. Nine of 30 (30.0%) of endoscopic and 15 of 76 (19.7%) of microscopic patients were pediatric. Endoscopic preoperative air conduction PTA0.5-2kHz was 52.1 ± 15.8 dB and 52.2 ± 17.9 dB for the microscopic group ( p > 0.05). Three months postoperative endoscopic air conduction PTA0.5-2kHz was 37.6 ± 17.4 dB (14.5 dB improvement) and 44.6 ± 19.9 dB (7.6 dB improvement) in the microscopic group ( p > 0.05). Three months postoperative endoscopic PTA0.5-2kHz ABG was 26.8 ± 16.6 dB and 28.4 ± 14.7 dB in the microscopic group ( p > 0.05). Latest follow-up endoscopic air conduction PTA0.5-2kHz audiogram (mean follow-up, 20.6 ± 10.4 mo) was 36.1 ± 18.2 dB (16.0 dB improvement) and 40.1 ± 16.8 dBAbstract : Objective: To compare short-term and long-term outcomes after transcanal endoscope-assisted with microscope-assisted ossiculoplasty using the Fisch titanium total prosthesis (FTTP). Study Design: Retrospective chart review. Setting: Tertiary referral center. Patients: Pediatric (<18 yr of age) and adult patients undergoing ossiculoplasty with the FTTP between January 2016 and December 2019. Intervention: Transcanal endoscope-assisted (n = 30) or microscope-assisted (n = 76) ossiculoplasty with the FTTP. In the microscopic group, 48 were performed through the ear canal and 28 by retroauricular approach. Main Outcome Measure: Short-term (3 mo) and long-term (average 20.2 mo) PTA0.5-2kHz air and bone conduction thresholds were evaluated. Results: In total, 106 patients were included. Nine of 30 (30.0%) of endoscopic and 15 of 76 (19.7%) of microscopic patients were pediatric. Endoscopic preoperative air conduction PTA0.5-2kHz was 52.1 ± 15.8 dB and 52.2 ± 17.9 dB for the microscopic group ( p > 0.05). Three months postoperative endoscopic air conduction PTA0.5-2kHz was 37.6 ± 17.4 dB (14.5 dB improvement) and 44.6 ± 19.9 dB (7.6 dB improvement) in the microscopic group ( p > 0.05). Three months postoperative endoscopic PTA0.5-2kHz ABG was 26.8 ± 16.6 dB and 28.4 ± 14.7 dB in the microscopic group ( p > 0.05). Latest follow-up endoscopic air conduction PTA0.5-2kHz audiogram (mean follow-up, 20.6 ± 10.4 mo) was 36.1 ± 18.2 dB (16.0 dB improvement) and 40.1 ± 16.8 dB (12.1 dB improvement) in the microscopic group (mean follow-up, 19.9 ± 10.3 mo)( p > 0.05). For endoscopic air conduction PTA0.5-2kHz, between the 3 months and latest follow-up audiogram, 25.0% showed improvement, 50.0% remained stable, and 25.0% deteriorated. In the microscopic group, 26.7% improved, 46.6% remained stable, and 26.7% deteriorated ( p > 0.05). Conclusion: Our study shows that hearing results with the Fisch titanium total prosthesis are in line with literature. Endoscope-assisted total ossiculoplasty proves to be a suitable technique with comparable results to the microscopic approach. … (more)
- Is Part Of:
- Otology & neurotology. Volume 43:Issue 10(2022)
- Journal:
- Otology & neurotology
- Issue:
- Volume 43:Issue 10(2022)
- Issue Display:
- Volume 43, Issue 10 (2022)
- Year:
- 2022
- Volume:
- 43
- Issue:
- 10
- Issue Sort Value:
- 2022-0043-0010-0000
- Page Start:
- 1189
- Page End:
- 1195
- Publication Date:
- 2022-12
- Subjects:
- Audiologic outcome -- Long-term -- Ossiculoplasty -- Total endoscopic ear surgery -- Total ossicular replacement prosthesis
Otology -- Periodicals
Ear -- Diseases -- Periodicals
Skull base -- Surgery -- Periodicals
617.8005 - Journal URLs:
- http://www.otology-neurotology.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MAO.0000000000003733 ↗
- Languages:
- English
- ISSNs:
- 1531-7129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6313.528000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 24256.xml