Minimally Invasive Sutureless Aortic Valve Replacement is Associated With Improved Outcomes in Patients With Left Ventricular Dysfunction. Issue 5 (September 2019)
- Record Type:
- Journal Article
- Title:
- Minimally Invasive Sutureless Aortic Valve Replacement is Associated With Improved Outcomes in Patients With Left Ventricular Dysfunction. Issue 5 (September 2019)
- Main Title:
- Minimally Invasive Sutureless Aortic Valve Replacement is Associated With Improved Outcomes in Patients With Left Ventricular Dysfunction
- Authors:
- Concistrè, Giovanni
Bianchi, Giacomo
Chiaramonti, Francesca
Margaryan, Rafik
Marchi, Federica
Kallushi, Enkel
Solinas, Marco - Abstract:
- Abstract : Objective: Patients with severe aortic stenosis and reduced left ventricular ejection fraction (LVEF) have a poor prognosis compared with patients with preserved LVEF. To evaluate the impact of sutureless Perceval (LivaNova, Italy) aortic bioprosthesis on LVEF and clinical outcomes in patients with baseline left ventricular (LV) dysfunction who underwent isolated aortic valve replacement (AVR). Methods: Between March 2011 and August 2017, 803 patients underwent AVR with Perceval bioprosthesis implantation. Fifty-two isolated AVR had preoperative LVEF ⩽45%. Mean age of these patients was 77 ± 6 years, 24 patients were female (46%), and mean EuroSCORE II was 9.4% ± 4.8%. Perceval bioprosthesis was implanted in 9 REDO operations. In 43 patients (83%), AVR was performed in minimally invasive surgery with an upper ministernotomy ( n = 13) or right anterior minithoracotomy ( n = 30). Results: One patient died in hospital. Cardiopulmonary bypass and aortic cross-clamp times were 85.5 ± 26 minutes and 55.5 ± 19 minutes, respectively. At mean follow-up of 33 ± 20 months (range: 1 to 75 months), survival was 90%, freedom from reoperation was 100%, and mean transvalvular pressure gradient was 11 ± 5 mmHg. LVEF improved from 37% ± 7% preoperatively to 43% ± 8% at discharge ( P < 0.01) and further increased to 47% ± 9% at follow-up ( P = 0.06), LV mass decreased from 149.8 ± 16.9 g/m 2 preoperatively to 115.3 ± 11.6 g/m 2 at follow-up ( P < 0.001), and moderate paravalvularAbstract : Objective: Patients with severe aortic stenosis and reduced left ventricular ejection fraction (LVEF) have a poor prognosis compared with patients with preserved LVEF. To evaluate the impact of sutureless Perceval (LivaNova, Italy) aortic bioprosthesis on LVEF and clinical outcomes in patients with baseline left ventricular (LV) dysfunction who underwent isolated aortic valve replacement (AVR). Methods: Between March 2011 and August 2017, 803 patients underwent AVR with Perceval bioprosthesis implantation. Fifty-two isolated AVR had preoperative LVEF ⩽45%. Mean age of these patients was 77 ± 6 years, 24 patients were female (46%), and mean EuroSCORE II was 9.4% ± 4.8%. Perceval bioprosthesis was implanted in 9 REDO operations. In 43 patients (83%), AVR was performed in minimally invasive surgery with an upper ministernotomy ( n = 13) or right anterior minithoracotomy ( n = 30). Results: One patient died in hospital. Cardiopulmonary bypass and aortic cross-clamp times were 85.5 ± 26 minutes and 55.5 ± 19 minutes, respectively. At mean follow-up of 33 ± 20 months (range: 1 to 75 months), survival was 90%, freedom from reoperation was 100%, and mean transvalvular pressure gradient was 11 ± 5 mmHg. LVEF improved from 37% ± 7% preoperatively to 43% ± 8% at discharge ( P < 0.01) and further increased to 47% ± 9% at follow-up ( P = 0.06), LV mass decreased from 149.8 ± 16.9 g/m 2 preoperatively to 115.3 ± 11.6 g/m 2 at follow-up ( P < 0.001), and moderate paravalvular leakage occurred in 1 patient without hemolysis not requiring any treatment. Conclusions: AVR with sutureless aortic bioprosthesis implantation in patients with preoperative LV dysfunction demonstrated a significant immediate and early improvement in LVEF. … (more)
- Is Part Of:
- Innovations. Volume 14:Issue 5(2019)
- Journal:
- Innovations
- Issue:
- Volume 14:Issue 5(2019)
- Issue Display:
- Volume 14, Issue 5 (2019)
- Year:
- 2019
- Volume:
- 14
- Issue:
- 5
- Issue Sort Value:
- 2019-0014-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-09
- Subjects:
- aortic valve replacement -- sutureless aortic bioprosthesis -- echocardiography -- left ventricular dysfunction -- minimally invasive surgery
Cardiovascular system -- Surgery -- Periodicals
Heart -- Surgery -- Periodicals
Blood-vessels -- Surgery -- Periodicals
Chest -- Surgery -- Periodicals
Thoracic Surgical Procedures -- methods -- Periodicals
Vascular Surgical Procedures -- methods -- Periodicals
Thorax -- Chirurgie -- Méthodologie -- Périodiques
Vaisseaux sanguins -- Chirurgie -- Méthodologie -- Périodiques
Blood-vessels -- Surgery
Chest -- Surgery
Periodicals
617.41 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01243895-000000000-00000 ↗
http://journals.lww.com/innovjournal/pages/default.aspx ↗
http://www.lww.com/product/?1556-9845 ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1177/1556984519872990 ↗
- Languages:
- English
- ISSNs:
- 1556-9845
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24262.xml