Watkinson, P - Abstract:
- Abstract: Objectives. Clinical assessment of skin perfusion informs prognosis in critically ill patients. Video camera monitoring could provide an objective, continuous method to monitor skin perfusion. In this prospective, interventional study of healthy volunteers, we tested whether video camera-derived photoplethysmography imaging and colour measurements could detect drug-induced skin perfusion changes. Approach. We monitored the lower limbs of 30 volunteers using video cameras while administering phenylephrine (a vasoconstrictor) and glyceryl trinitrate (a vasodilator). We report relative pixel intensity changes from baseline, as absolute values are sensitive to environmental factors. The primary outcome was the pre- to peak- infusion green channel amplitude change in the pulsatile PPGi waveform component. Secondary outcomes were pre-to-peak changes in the photoplethysmographic imaging waveform baseline, skin colour hue and skin colour saturation. Main results. The 30 participants had a median age of 29 years (IQR 25–34), sixteen (53%) were male. A 34.7% ( p = 0.0001) mean decrease in the amplitude of the pulsatile photoplethysmographic imaging waveform occurred following phenylephrine infusion. A 30.7% ( p = 0.000004) mean increase occurred following glyceryl trinitrate infusion. The photoplethysmographic imaging baseline decreased with phenylephrine by 2.1% ( p = 0.000 02) and increased with glyceryl trinitrate by 0.5% ( p = 0.026). Skin colour hue changed in oppositeAbstract: Objectives. Clinical assessment of skin perfusion informs prognosis in critically ill patients. Video camera monitoring could provide an objective, continuous method to monitor skin perfusion. In this prospective, interventional study of healthy volunteers, we tested whether video camera-derived photoplethysmography imaging and colour measurements could detect drug-induced skin perfusion changes. Approach. We monitored the lower limbs of 30 volunteers using video cameras while administering phenylephrine (a vasoconstrictor) and glyceryl trinitrate (a vasodilator). We report relative pixel intensity changes from baseline, as absolute values are sensitive to environmental factors. The primary outcome was the pre- to peak- infusion green channel amplitude change in the pulsatile PPGi waveform component. Secondary outcomes were pre-to-peak changes in the photoplethysmographic imaging waveform baseline, skin colour hue and skin colour saturation. Main results. The 30 participants had a median age of 29 years (IQR 25–34), sixteen (53%) were male. A 34.7% ( p = 0.0001) mean decrease in the amplitude of the pulsatile photoplethysmographic imaging waveform occurred following phenylephrine infusion. A 30.7% ( p = 0.000004) mean increase occurred following glyceryl trinitrate infusion. The photoplethysmographic imaging baseline decreased with phenylephrine by 2.1% ( p = 0.000 02) and increased with glyceryl trinitrate by 0.5% ( p = 0.026). Skin colour hue changed in opposite direction with phenylephrine (−0.0013, p = 0.0002) and glyceryl trinitrate (+0.0006, p = 0.019). Skin colour saturation decreased with phenylephrine by 0.0022 ( p = 0.0002), with no significant change observed with glyceryl trinitrate (+0.0005, p = 0.21). Significance. Drug-induced vasoconstriction and vasodilation are associated with detectable changes in photoplethysmographic imaging waveform parameters and skin hue. Our findings suggest video cameras have great potential for continuous, contactless skin perfusion monitoring. … (more)
- Is Part Of:
- Physiological measurement. Volume 43:Number 11(2022)
- Journal:
- Physiological measurement
- Issue:
- Volume 43:Number 11(2022)
- Issue Display:
- Volume 43, Issue 11 (2022)
- Year:
- 2022
- Volume:
- 43
- Issue:
- 11
- Issue Sort Value:
- 2022-0043-0011-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-11-30
- Subjects:
- perfusion -- monitoring -- non-contact -- camera
Physiology -- Measurement -- Periodicals
Patient monitoring -- Periodicals
612 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0967-3334 ↗ - DOI:
- 10.1088/1361-6579/ac9c82 ↗
- Languages:
- English
- ISSNs:
- 0967-3334
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 24262.xml