A wear model to predict damage of reconstructed ACL. (December 2022)
- Record Type:
- Journal Article
- Title:
- A wear model to predict damage of reconstructed ACL. (December 2022)
- Main Title:
- A wear model to predict damage of reconstructed ACL
- Authors:
- Maeztu Redin, Deyo
Caroux, Julien
Rohan, Pierre-Yves
Pillet, Hélène
Cermolacce, Alexia
Trnka, Julien
Manassero, Mathieu
Viateau, Véronique
Corté, Laurent - Abstract:
- Abstract: Impingement with surrounding tissues is a major cause of failure of anterior cruciate ligament reconstruction. However, the complexity of the knee kinematics and anatomical variations make it difficult to predict the occurrence of contact and the extent of the resulting damage. Here we hypothesise that a description of wear between the reconstructed ligament and adjacent structures captures the in vivo damage produced with physiological loadings. To test this, we performed an in vivo study on a sheep model and investigated the role of different sources of damage: overstretching, excessive twist, excessive compression, and wear. Seven sheep underwent cranial cruciate ligament reconstruction using a tendon autograft. Necropsy observations and pull-out force measurements performed postoperatively at three months showed high variability across specimens of the extent and location of graft damage. Using 3D digital models of each stifle based on X-ray imaging and kinematics measurements, we determined the relative displacements between the graft and the surrounding bones and computed a wear index describing the work of friction forces underwent by the graft during a full flexion-extension movement. While tensile strain, angle of twist and impingement volume showed no correlation with pull-out force (ρ = −0.321, p = 0.498), the wear index showed a strong negative correlation (r = −0.902, p = 0.006). Moreover, contour maps showing the distribution of wear on the graft wereAbstract: Impingement with surrounding tissues is a major cause of failure of anterior cruciate ligament reconstruction. However, the complexity of the knee kinematics and anatomical variations make it difficult to predict the occurrence of contact and the extent of the resulting damage. Here we hypothesise that a description of wear between the reconstructed ligament and adjacent structures captures the in vivo damage produced with physiological loadings. To test this, we performed an in vivo study on a sheep model and investigated the role of different sources of damage: overstretching, excessive twist, excessive compression, and wear. Seven sheep underwent cranial cruciate ligament reconstruction using a tendon autograft. Necropsy observations and pull-out force measurements performed postoperatively at three months showed high variability across specimens of the extent and location of graft damage. Using 3D digital models of each stifle based on X-ray imaging and kinematics measurements, we determined the relative displacements between the graft and the surrounding bones and computed a wear index describing the work of friction forces underwent by the graft during a full flexion-extension movement. While tensile strain, angle of twist and impingement volume showed no correlation with pull-out force (ρ = −0.321, p = 0.498), the wear index showed a strong negative correlation (r = −0.902, p = 0.006). Moreover, contour maps showing the distribution of wear on the graft were consistent with the observations of damage during the necropsy. These results demonstrate that wear is a good proxy of graft damage. The proposed wear index could be used in implant design and surgery planning to minimise the risk of implant failure. Its application to sheep can provide a way to increase preclinical testing efficiency. … (more)
- Is Part Of:
- Journal of the mechanical behavior of biomedical materials. Volume 136(2022)
- Journal:
- Journal of the mechanical behavior of biomedical materials
- Issue:
- Volume 136(2022)
- Issue Display:
- Volume 136, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 136
- Issue:
- 2022
- Issue Sort Value:
- 2022-0136-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-12
- Subjects:
- ACL -- Ligament reconstruction -- Wear -- Surgery planning -- Animal model
Biomedical materials -- Periodicals
Biomedical materials -- Mechanical properties -- Periodicals
Biomedical materials
Biomedical materials -- Mechanical properties
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17516161 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jmbbm.2022.105426 ↗
- Languages:
- English
- ISSNs:
- 1751-6161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5015.809000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24252.xml