Evaluation of CT dose and establishment of local DRLs for abdomen and pelvis examinations in hospitals in Taif City, Saudi Arabia. (January 2023)
- Record Type:
- Journal Article
- Title:
- Evaluation of CT dose and establishment of local DRLs for abdomen and pelvis examinations in hospitals in Taif City, Saudi Arabia. (January 2023)
- Main Title:
- Evaluation of CT dose and establishment of local DRLs for abdomen and pelvis examinations in hospitals in Taif City, Saudi Arabia
- Authors:
- Osman, Hamid
Alosaimi, Maathir
Alghamdi, Fai
Aljuaid, Atheer
Alqurashi, Manar
Aldajani, Shihanah
Faizo, Nahla L.
Alamri, Sultan
Althobaiti, Yazeed S.
Khandaker, Mayeen Uddin
Suleiman, Abdelmoneim - Abstract:
- Abstract: This study measures the CT dose of the abdomen and pelvic examinations for adult patients, as well as establishes the provincial diagnostic reference level (DRL) for hospitals in Taif city, Saudi Arabia. A total of 200 patients who underwent pelvis and abdomen examinations in two main hospitals in Taif city were selected for this study. The data were collected in a spreadsheet that records patients' demographic data, exposure parameters and dose indicators such as dose length product (DLP) and volume computed tomography dose index (CTDIvol) for each examination. The patients' average age and BMI were 37.3 years and 25.5 kg/m 2, respectively. The mean DLP and CTDIvol for the pelvis were found to be 379.6 mGy-cm and 10.8 mGy, respectively, whereas the corresponding mean values for the abdomen were 369.5 mGy-cm and 11.5 mGy, respectively. The average effective dosages for the abdomen and pelvis in both hospitals were estimated to be 5.6 and 7.2 mSv, respectively. Based on the third quartile data of DLP and CTDIvol, this study suggests DRL for pelvic DLP and CTDIw are 402.5 mGy-cm and 21.8 mGy, respectively, whereas the respective values are 407.5 mGy-cm and 18.4 mGy for CT abdominal DLP and CTDIw. The present study reports lower values for effective dose and DRL when compared with earlier data available in the literature. However, this work suggests further studies with different kV stations on pediatric patients in the future. Highlights: Radiation dose for adult CTAbstract: This study measures the CT dose of the abdomen and pelvic examinations for adult patients, as well as establishes the provincial diagnostic reference level (DRL) for hospitals in Taif city, Saudi Arabia. A total of 200 patients who underwent pelvis and abdomen examinations in two main hospitals in Taif city were selected for this study. The data were collected in a spreadsheet that records patients' demographic data, exposure parameters and dose indicators such as dose length product (DLP) and volume computed tomography dose index (CTDIvol) for each examination. The patients' average age and BMI were 37.3 years and 25.5 kg/m 2, respectively. The mean DLP and CTDIvol for the pelvis were found to be 379.6 mGy-cm and 10.8 mGy, respectively, whereas the corresponding mean values for the abdomen were 369.5 mGy-cm and 11.5 mGy, respectively. The average effective dosages for the abdomen and pelvis in both hospitals were estimated to be 5.6 and 7.2 mSv, respectively. Based on the third quartile data of DLP and CTDIvol, this study suggests DRL for pelvic DLP and CTDIw are 402.5 mGy-cm and 21.8 mGy, respectively, whereas the respective values are 407.5 mGy-cm and 18.4 mGy for CT abdominal DLP and CTDIw. The present study reports lower values for effective dose and DRL when compared with earlier data available in the literature. However, this work suggests further studies with different kV stations on pediatric patients in the future. Highlights: Radiation dose for adult CT abdomen and pelvis were assessed. Average DLP and CTDIw for adult CT abdomen and pelvis were evaluated. Average patient effective dose for CT abdomen and pelvis were estimated to be 5.6 and 7.2 mSv. Third quartile of DLP and CTDIw was used to establish provincial DRL. … (more)
- Is Part Of:
- Radiation physics and chemistry. Volume 202(2023)
- Journal:
- Radiation physics and chemistry
- Issue:
- Volume 202(2023)
- Issue Display:
- Volume 202, Issue 2023 (2023)
- Year:
- 2023
- Volume:
- 202
- Issue:
- 2023
- Issue Sort Value:
- 2023-0202-2023-0000
- Page Start:
- Page End:
- Publication Date:
- 2023-01
- Subjects:
- CT dose -- Pelvis and abdomen -- Taif city hospitals -- Local DRLs
Radiation chemistry -- Periodicals
Radiometry -- Periodicals
Radiation -- Periodicals
Chimie sous rayonnement -- Périodiques
539.2 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0969806X ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiation-physics-and-chemistry/ ↗ - DOI:
- 10.1016/j.radphyschem.2022.110206 ↗
- Languages:
- English
- ISSNs:
- 0969-806X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.984000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24259.xml