Dynamic cardiac PET motion correction using 3D normalized gradient fields in patients and phantom simulations. Issue 9 (20th July 2021)
- Record Type:
- Journal Article
- Title:
- Dynamic cardiac PET motion correction using 3D normalized gradient fields in patients and phantom simulations. Issue 9 (20th July 2021)
- Main Title:
- Dynamic cardiac PET motion correction using 3D normalized gradient fields in patients and phantom simulations
- Authors:
- Nye, Jonathon A.
Piccinelli, Marina
Hwang, Doyeon
David Cooke, Charles
Paeng, Jin Chul
Lee, Joo Myung
Cho, Sang‐Geon
Folks, Russell
Bom, Hee‐Seung
Koo, Bon‐Kwon
Garcia, Ernest V. - Abstract:
- Abstract: This work expands on the implementation of three‐dimensional (3D) normalized gradient fields to correct for whole‐body motion and cardiac creep in [N‐13]‐ammonia patient studies and evaluates its accuracy using a dynamic phantom simulation model. Methods: A full rigid‐body algorithm was developed using 3D normalized gradient fields including a multi‐resolution step and sampling off the voxel grid to reduce interpolation artifacts. Optimization was performed using a weighted similarity metric that accounts for opposing gradients between images of blood pool and perfused tissue without the need for segmentation. Forty‐three retrospective dynamic [N‐13]‐ammonia PET/CT rest/adenosine‐stress patient studies were motion corrected and the mean motion parameters plotted at each frame time point. Motion correction accuracy was assessed using a comprehensive dynamic XCAT simulation incorporating published physiologic parameters of the heart's trajectory following adenosine infusion as well as corrupted attenuation correction commonly observed in clinical studies. Accuracy of the algorithm was assessed objectively by comparing the errors between isosurfaces and centers of mass of the motion corrected XCAT simulations. Results: In the patient studies, the overall mean cranial‐to‐caudal translation was 7 mm at stress over the duration of the adenosine infusion. Noninvasive clinical measures of relative flow reserve and myocardial flow reserve were highly correlated with theirAbstract: This work expands on the implementation of three‐dimensional (3D) normalized gradient fields to correct for whole‐body motion and cardiac creep in [N‐13]‐ammonia patient studies and evaluates its accuracy using a dynamic phantom simulation model. Methods: A full rigid‐body algorithm was developed using 3D normalized gradient fields including a multi‐resolution step and sampling off the voxel grid to reduce interpolation artifacts. Optimization was performed using a weighted similarity metric that accounts for opposing gradients between images of blood pool and perfused tissue without the need for segmentation. Forty‐three retrospective dynamic [N‐13]‐ammonia PET/CT rest/adenosine‐stress patient studies were motion corrected and the mean motion parameters plotted at each frame time point. Motion correction accuracy was assessed using a comprehensive dynamic XCAT simulation incorporating published physiologic parameters of the heart's trajectory following adenosine infusion as well as corrupted attenuation correction commonly observed in clinical studies. Accuracy of the algorithm was assessed objectively by comparing the errors between isosurfaces and centers of mass of the motion corrected XCAT simulations. Results: In the patient studies, the overall mean cranial‐to‐caudal translation was 7 mm at stress over the duration of the adenosine infusion. Noninvasive clinical measures of relative flow reserve and myocardial flow reserve were highly correlated with their invasive analogues. Motion correction accuracy assessed with the XCAT simulations showed an error of <1 mm in late perfusion frames that broadened gradually to <3 mm in earlier frames containing blood pool. Conclusion: This work demonstrates that patients undergoing [N‐13]‐ammonia dynamic PET/CT exhibit a large cranial‐to‐caudal translation related to cardiac creep primarily at stress and to a lesser extent at rest, which can be accurately corrected by optimizing their 3D normalized gradient fields. Our approach provides a solution to the challenging condition where the image intensity and its gradients are opposed without the need for segmentation and remains robust in the presence of PET‐CT mismatch. … (more)
- Is Part Of:
- Medical physics. Volume 48:Issue 9(2021)
- Journal:
- Medical physics
- Issue:
- Volume 48:Issue 9(2021)
- Issue Display:
- Volume 48, Issue 9 (2021)
- Year:
- 2021
- Volume:
- 48
- Issue:
- 9
- Issue Sort Value:
- 2021-0048-0009-0000
- Page Start:
- 5072
- Page End:
- 5084
- Publication Date:
- 2021-07-20
- Subjects:
- cardiac PET -- phantoms -- registration
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.15059 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24248.xml