Assessment of Indoor Levels of Carbon Monoxide Emission from Smoldering Mosquito Coils Used in Nigeria. (April 2022)
- Record Type:
- Journal Article
- Title:
- Assessment of Indoor Levels of Carbon Monoxide Emission from Smoldering Mosquito Coils Used in Nigeria. (April 2022)
- Main Title:
- Assessment of Indoor Levels of Carbon Monoxide Emission from Smoldering Mosquito Coils Used in Nigeria
- Authors:
- Elehinafe, Francis Boluwaji
Okedere, Oyetunji Babatunde
Adesanmi, Adewole Johnson
Jimoh, Eniola Mistura - Abstract:
- Mosquito coils are commonly burnt in indoor environments to drive away mosquitoes which are vectors for malaria parasites. The levels of carbon monoxide (CO) emitted and human health implications during smoldering of 5 different brands of mosquito coils commonly used in Nigeria were investigated in 4 microenvironments of different sizes. The experiments were done by taking a scenario of a sleeping arrangement and the farthest distance between the coil burning and an arbitrary bed position in 4 different bedrooms of different sizes in poor ventilation condition of closed doors and windows. With monitoring device, ALTAIR 5X portable gas analyzer, at the position of the bed, measurements were taking at 2 minutes interval from start to the end of burning of each coil. The emission profile was determined by making concentration-time plots of CO emission to determine its levels from the burning of each brand of the mosquito coils in each microenvironment. From the emission profile, coils A, C, and D showed that CO levels exceeded Nigeria's Federal Ministry of Environment (FMEnv) and the World Health Organization (WHO) statutory limit of 9.0 ppm for indoor environments in each of the microenvironments between 3 and 7 hours after the burning commenced. It was concluded that the CO concentrations from smoldering mosquito coils is a function of the size of the microenvironment in which it is used. It was recommended that the size of a microenvironment be determined for consumption ofMosquito coils are commonly burnt in indoor environments to drive away mosquitoes which are vectors for malaria parasites. The levels of carbon monoxide (CO) emitted and human health implications during smoldering of 5 different brands of mosquito coils commonly used in Nigeria were investigated in 4 microenvironments of different sizes. The experiments were done by taking a scenario of a sleeping arrangement and the farthest distance between the coil burning and an arbitrary bed position in 4 different bedrooms of different sizes in poor ventilation condition of closed doors and windows. With monitoring device, ALTAIR 5X portable gas analyzer, at the position of the bed, measurements were taking at 2 minutes interval from start to the end of burning of each coil. The emission profile was determined by making concentration-time plots of CO emission to determine its levels from the burning of each brand of the mosquito coils in each microenvironment. From the emission profile, coils A, C, and D showed that CO levels exceeded Nigeria's Federal Ministry of Environment (FMEnv) and the World Health Organization (WHO) statutory limit of 9.0 ppm for indoor environments in each of the microenvironments between 3 and 7 hours after the burning commenced. It was concluded that the CO concentrations from smoldering mosquito coils is a function of the size of the microenvironment in which it is used. It was recommended that the size of a microenvironment be determined for consumption of a mosquito coil before it is released into the market. … (more)
- Is Part Of:
- Environmental health insights. Volume 16(2022)
- Journal:
- Environmental health insights
- Issue:
- Volume 16(2022)
- Issue Display:
- Volume 16, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 16
- Issue:
- 2022
- Issue Sort Value:
- 2022-0016-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-04
- Subjects:
- Mosquito coils -- burning -- emission -- carbon monoxide -- levels of exposure -- Nigeria
Environmental health -- Periodicals
Health risk assessment -- Periodicals
Environmental Health
Risk Assessment
Environmental health
Health risk assessment
Electronic journals
Periodicals
Fulltext
Internet Resources
Periodicals
Periodicals
613.105 - Journal URLs:
- http://insights.sagepub.com/journal-environmental-health-insights-j110 ↗
http://www.uk.sagepub.com/home.nav ↗
http://la-press.com/journal.php?journal_id=110&issue_id=125 ↗
http://bibpurl.oclc.org/web/40916 ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/1224/ ↗ - DOI:
- 10.1177/11786302221091031 ↗
- Languages:
- English
- ISSNs:
- 1178-6302
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24241.xml