Artificial intelligence-enabled electrocardiogram screens low left ventricular ejection fraction with a degree of confidence. (December 2022)
- Record Type:
- Journal Article
- Title:
- Artificial intelligence-enabled electrocardiogram screens low left ventricular ejection fraction with a degree of confidence. (December 2022)
- Main Title:
- Artificial intelligence-enabled electrocardiogram screens low left ventricular ejection fraction with a degree of confidence
- Authors:
- Lee, Chun-Ho
Liu, Wei-Ting
Lou, Yu-Sheng
Lin, Chin-Sheng
Fang, Wen-Hui
Lee, Chia-Cheng
Ho, Ching-Liang
Wang, Chih-Hung
Lin, Chin - Abstract:
- Background: Artificial intelligence-enabled electrocardiogram has become a substitute tool for echocardiography in left ventricular ejection fraction estimation. However, the direct use of artificial intelligence-enabled electrocardiogram may be not trustable due to the uncertainty of the prediction. Objective: The study aimed to establish an artificial intelligence-enabled electrocardiogram with a degree of confidence to identify left ventricular dysfunction. Methods: The study collected 76, 081 and 11, 771 electrocardiograms from an academic medical center and a community hospital to establish and validate the deep learning model, respectively. The proposed deep learning model provided the point estimation of the actual ejection fraction and its standard deviation derived from the maximum probability density function of a normal distribution. The primary analysis focused on the accuracy of identifying patients with left ventricular dysfunction (ejection fraction ≤ 40%). Since the standard deviation was an uncertainty indicator in a normal distribution, we used it as a degree of confidence in the artificial intelligence-enabled electrocardiogram. We further explored the clinical application of estimated standard deviation and followed up on the new-onset left ventricular dysfunction in patients with initially normal ejection fraction. Results: The area under receiver operating characteristic curves (AUC) of detecting left ventricular dysfunction were 0.9549 and 0.9365 inBackground: Artificial intelligence-enabled electrocardiogram has become a substitute tool for echocardiography in left ventricular ejection fraction estimation. However, the direct use of artificial intelligence-enabled electrocardiogram may be not trustable due to the uncertainty of the prediction. Objective: The study aimed to establish an artificial intelligence-enabled electrocardiogram with a degree of confidence to identify left ventricular dysfunction. Methods: The study collected 76, 081 and 11, 771 electrocardiograms from an academic medical center and a community hospital to establish and validate the deep learning model, respectively. The proposed deep learning model provided the point estimation of the actual ejection fraction and its standard deviation derived from the maximum probability density function of a normal distribution. The primary analysis focused on the accuracy of identifying patients with left ventricular dysfunction (ejection fraction ≤ 40%). Since the standard deviation was an uncertainty indicator in a normal distribution, we used it as a degree of confidence in the artificial intelligence-enabled electrocardiogram. We further explored the clinical application of estimated standard deviation and followed up on the new-onset left ventricular dysfunction in patients with initially normal ejection fraction. Results: The area under receiver operating characteristic curves (AUC) of detecting left ventricular dysfunction were 0.9549 and 0.9365 in internal and external validation sets. After excluding the cases with a lower degree of confidence, the artificial intelligence-enabled electrocardiogram performed better in the remaining cases in internal (AUC = 0.9759) and external (AUC = 0.9653) validation sets. For the application of future left ventricular dysfunction risk stratification in patients with initially normal ejection fraction, a 4.57-fold risk of future left ventricular dysfunction when the artificial intelligence-enabled electrocardiogram is positive in the internal validation set. The hazard ratio was increased to 8.67 after excluding the cases with a lower degree of confidence. This trend was also validated in the external validation set. Conclusion: The deep learning model with a degree of confidence can provide advanced improvements in identifying left ventricular dysfunction and serve as a decision support and management-guided screening tool for prognosis. … (more)
- Is Part Of:
- Digital health. Volume 8(2022)
- Journal:
- Digital health
- Issue:
- Volume 8(2022)
- Issue Display:
- Volume 8, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 8
- Issue:
- 2022
- Issue Sort Value:
- 2022-0008-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-12
- Subjects:
- Artificial intelligence -- electrocardiogram -- deep learning -- ejection fraction -- continuous numerical prediction -- degree of confidence
Medical care -- Data processing -- Periodicals
Medical informatics -- Periodicals
362.10285 - Journal URLs:
- http://www.uk.sagepub.com/home.nav ↗
http://dhj.sagepub.com/ ↗ - DOI:
- 10.1177/20552076221143249 ↗
- Languages:
- English
- ISSNs:
- 2055-2076
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24208.xml