Validating the accuracy of a novel virtual reality platform for determining implant orientation in simulated primary total hip replacement. (December 2022)
- Record Type:
- Journal Article
- Title:
- Validating the accuracy of a novel virtual reality platform for determining implant orientation in simulated primary total hip replacement. (December 2022)
- Main Title:
- Validating the accuracy of a novel virtual reality platform for determining implant orientation in simulated primary total hip replacement
- Authors:
- Howgate, Daniel
Oliver, Michael
Stebbins, Julie
Roberts, Patrick Garfjeld
Kendrick, Ben
Rees, Jonathan
Taylor, Stephen - Abstract:
- Introduction: Accurate acetabular cup and femoral stem component orientation are critical for optimising patient outcomes, reducing complications and increasing component longevity following total hip replacement (THR). This study aimed to determine the accuracy of a novel virtual reality (VR) platform in assessing component orientation in a simulated THR model. Methods: The VR platform (HTC Vive Pro® system hardware) was compared against the validated Vicon® optical motion capture (MoCap) system. An acetabular cup and femoral stem were manually implanted across a range of orientations into pelvic and femur sawbones, respectively. Simultaneous readings of the acetabular cup operative anteversion (OA) and inclination (OI) and femoral stem alignment (FSA) and neck anteversion (FNA) were obtained from the VR and MoCap systems. Statistical analysis was performed using Pearson product-moment correlation coefficient (PPMCC) (Pearson's r) and linear regression (R 2 ). Results: A total of 55 readings were obtained for the acetabular cup and 68 for the femoral stem model. The mean average differences in OA, OI, FSA and FNA between the systems were 3.44°, −0.01°, 0.01° and −0.04°, respectively. Strong positive correlations were demonstrated between both systems in OA, OI, FSA and FNA, with Pearson's r = 0.92, 0.94, 0.99 and 0.99, and adjusted R 2 = 0.82, 0.9, 0.98 and 0.98, respectively. Conclusion: The novel VR platform is highly accurate and reliable in determining both acetabularIntroduction: Accurate acetabular cup and femoral stem component orientation are critical for optimising patient outcomes, reducing complications and increasing component longevity following total hip replacement (THR). This study aimed to determine the accuracy of a novel virtual reality (VR) platform in assessing component orientation in a simulated THR model. Methods: The VR platform (HTC Vive Pro® system hardware) was compared against the validated Vicon® optical motion capture (MoCap) system. An acetabular cup and femoral stem were manually implanted across a range of orientations into pelvic and femur sawbones, respectively. Simultaneous readings of the acetabular cup operative anteversion (OA) and inclination (OI) and femoral stem alignment (FSA) and neck anteversion (FNA) were obtained from the VR and MoCap systems. Statistical analysis was performed using Pearson product-moment correlation coefficient (PPMCC) (Pearson's r) and linear regression (R 2 ). Results: A total of 55 readings were obtained for the acetabular cup and 68 for the femoral stem model. The mean average differences in OA, OI, FSA and FNA between the systems were 3.44°, −0.01°, 0.01° and −0.04°, respectively. Strong positive correlations were demonstrated between both systems in OA, OI, FSA and FNA, with Pearson's r = 0.92, 0.94, 0.99 and 0.99, and adjusted R 2 = 0.82, 0.9, 0.98 and 0.98, respectively. Conclusion: The novel VR platform is highly accurate and reliable in determining both acetabular cup and femoral stem component orientations in simulated THR models. This adaptable and cost-effective digital tracking platform may be modified for use in a range of simulated surgical training and educational purposes, particularly in orthopaedic surgery. … (more)
- Is Part Of:
- Digital health. Volume 8(2022)
- Journal:
- Digital health
- Issue:
- Volume 8(2022)
- Issue Display:
- Volume 8, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 8
- Issue:
- 2022
- Issue Sort Value:
- 2022-0008-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-12
- Subjects:
- Total hip replacement -- medical education -- surgical training -- surgical simulation -- implant positioning -- virtual reality
Medical care -- Data processing -- Periodicals
Medical informatics -- Periodicals
362.10285 - Journal URLs:
- http://www.uk.sagepub.com/home.nav ↗
http://dhj.sagepub.com/ ↗ - DOI:
- 10.1177/20552076221141215 ↗
- Languages:
- English
- ISSNs:
- 2055-2076
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24208.xml