Assessing the Effect of Directional Bremsstrahlung Splitting on the Output Spectra and Parameters Using BEAMnrc Monte Carlo Simulation Package. (November 2022)
- Record Type:
- Journal Article
- Title:
- Assessing the Effect of Directional Bremsstrahlung Splitting on the Output Spectra and Parameters Using BEAMnrc Monte Carlo Simulation Package. (November 2022)
- Main Title:
- Assessing the Effect of Directional Bremsstrahlung Splitting on the Output Spectra and Parameters Using BEAMnrc Monte Carlo Simulation Package
- Authors:
- Babapour, Hamed
Semyari, Somayeh
Yadollahi, Masoumeh
Majdaeen, Mehrsa
Abedi-Firouzjah, Razzagh
Ataei, Gholamreza - Abstract:
- Introduction: EGSnrc software package is one of the computational packages for Monte Carlo simulation in radiation therapy and has several subset codes. Directional bremsstrahlung splitting (DBS) is a technique that applies braking radiations in interactions in this software. This study aimed to evaluate the effect of this technique on the simulation time, uncertainty, particle number of phase-space data, and photon beam spectrum resulting from a medical linear accelerator (LINAC). Materials and methods: The gantry of the accelerator, including the materials and geometries of different parts, was simulated using the BEAMnrc code (a subset code in the EGSnrc package). The phase-space data were recorded in different parts of the LINAC. The DBS values (1, 10, 100, and 1000) were changed, and their effects were evaluated on the simulation parameters and output spectra. Results: Increasing the DBS value from 1 to 1000 resulted in an increase in the simulation time from 1.778 to 11.310 hours, and increasing the number of particles in the phase-space plane (5 590 732-180 328 382). When the DBS had been picked up from 1 to 100, the simulation uncertainty decreased by about 1.29%. In addition, the DBS increment value from 100 to 1000 leads to an increase in uncertainty and simulation time of about 0.71% and 315%, respectively. Conclusion: Although using the DBS technique reduces the simulation time or uncertainty, increasing the DBS from a specific value, equal to 100 in our study,Introduction: EGSnrc software package is one of the computational packages for Monte Carlo simulation in radiation therapy and has several subset codes. Directional bremsstrahlung splitting (DBS) is a technique that applies braking radiations in interactions in this software. This study aimed to evaluate the effect of this technique on the simulation time, uncertainty, particle number of phase-space data, and photon beam spectrum resulting from a medical linear accelerator (LINAC). Materials and methods: The gantry of the accelerator, including the materials and geometries of different parts, was simulated using the BEAMnrc code (a subset code in the EGSnrc package). The phase-space data were recorded in different parts of the LINAC. The DBS values (1, 10, 100, and 1000) were changed, and their effects were evaluated on the simulation parameters and output spectra. Results: Increasing the DBS value from 1 to 1000 resulted in an increase in the simulation time from 1.778 to 11.310 hours, and increasing the number of particles in the phase-space plane (5 590 732-180 328 382). When the DBS had been picked up from 1 to 100, the simulation uncertainty decreased by about 1.29%. In addition, the DBS increment value from 100 to 1000 leads to an increase in uncertainty and simulation time of about 0.71% and 315%, respectively. Conclusion: Although using the DBS technique reduces the simulation time or uncertainty, increasing the DBS from a specific value, equal to 100 in our study, increases simulation uncertainties and times. Therefore, we propose considering a specific DBS value as we obtained for the Monte Carlo simulation of photon beams produced by linear accelerators. … (more)
- Is Part Of:
- Biomedical engineering and computational biology. Volume 13(2022)
- Journal:
- Biomedical engineering and computational biology
- Issue:
- Volume 13(2022)
- Issue Display:
- Volume 13, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 13
- Issue:
- 2022
- Issue Sort Value:
- 2022-0013-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-11
- Subjects:
- Directional bremsstrahlung splitting -- BEAMnrc Monte Carlo -- phase-space data
Biomedical engineering -- Periodicals
Computational biology -- Periodicals
Biomedical Engineering
Computational Biology
Biomedical engineering
Computational biology
Electronic journals
Periodicals
Fulltext
Internet Resources
Periodicals
Periodicals
610.2805 - Journal URLs:
- http://insights.sagepub.com/journal-biomedical-engineering-and-computational-biology-j170 ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/11795972221138473 ↗
- Languages:
- English
- ISSNs:
- 1179-5972
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24242.xml