Use of ABC/2 method for rapidly estimating the target mismatch on computed tomography perfusion imaging in patients with acute ischemic stroke. (January 2023)
- Record Type:
- Journal Article
- Title:
- Use of ABC/2 method for rapidly estimating the target mismatch on computed tomography perfusion imaging in patients with acute ischemic stroke. (January 2023)
- Main Title:
- Use of ABC/2 method for rapidly estimating the target mismatch on computed tomography perfusion imaging in patients with acute ischemic stroke
- Authors:
- Shen, Guang-Chen
Chu, Yue
Ma, Gao
Xu, Xiao-Quan
Lu, Shan-Shan
Shi, Hai-Bin
Wu, Fei-Yun - Abstract:
- Background: Target mismatch (ischemic core, mismatch volume and mismatch ratio) in patients with acute ischemic stroke (AIS) highly relies on the automated perfusion analysis software. Purpose: To evaluate the feasibility and accuracy of using the ABC/2 method to rapidly estimate the target mismatch on computed tomography perfusion (CTP) imaging in patients with AIS, using RAPID results as a reference. Material and Methods: In total, 243 patients with anterior circulation AIS who underwent CTP imaging were retrospectively reviewed. Target mismatch associated perfusion parameters were derived from RAPID results and calculated using the ABC/2 method. Paired t -test was used to assess the difference of volumetric parameters between the two methods. The ability of using the ABC/2 method to predict the important cutoff volumetric metrics was also evaluated. Result: There was no significant difference in the volumes of ischemic core ( P = 0.068), ischemic area ( P = 0.209), and mismatch volume ( P = 0.518) between ABC/2 and RAPID. Using RAPID results as reference, the ABC/2 method showed high accuracy for predicting perfusion parameters (70 mL and 90 mL: sensitivity=98.5% and 98.5%, specificity=100% and 100%, positive predictive value [PPV]=100% and 100%, negative predictive value [NPV]=93.8% and 92.9%; 10 mL and 15mL: sensitivity=99.6% and 99.5%, specificity=55.6% and 50.0%, PPV=96.6% and 94.8%, NPV=90.9% and 92.3%; 1.2 and 1.8: sensitivity=99.6% and 94.8%, specificity=75.0%Background: Target mismatch (ischemic core, mismatch volume and mismatch ratio) in patients with acute ischemic stroke (AIS) highly relies on the automated perfusion analysis software. Purpose: To evaluate the feasibility and accuracy of using the ABC/2 method to rapidly estimate the target mismatch on computed tomography perfusion (CTP) imaging in patients with AIS, using RAPID results as a reference. Material and Methods: In total, 243 patients with anterior circulation AIS who underwent CTP imaging were retrospectively reviewed. Target mismatch associated perfusion parameters were derived from RAPID results and calculated using the ABC/2 method. Paired t -test was used to assess the difference of volumetric parameters between the two methods. The ability of using the ABC/2 method to predict the important cutoff volumetric metrics was also evaluated. Result: There was no significant difference in the volumes of ischemic core ( P = 0.068), ischemic area ( P = 0.209), and mismatch volume ( P = 0.518) between ABC/2 and RAPID. Using RAPID results as reference, the ABC/2 method showed high accuracy for predicting perfusion parameters (70 mL and 90 mL: sensitivity=98.5% and 98.5%, specificity=100% and 100%, positive predictive value [PPV]=100% and 100%, negative predictive value [NPV]=93.8% and 92.9%; 10 mL and 15mL: sensitivity=99.6% and 99.5%, specificity=55.6% and 50.0%, PPV=96.6% and 94.8%, NPV=90.9% and 92.3%; 1.2 and 1.8: sensitivity=99.6% and 94.8%, specificity=75.0% and 96.9%, PPV=98.7% and 99.5%, NPV=90.0% and 73.8%). Conclusion: The ABC/2 method may be a feasible alternative to RAPID for estimation of target mismatch parameters on CTP in patients with AIS. … (more)
- Is Part Of:
- Acta radiologica. Volume 64:Number 1(2023)
- Journal:
- Acta radiologica
- Issue:
- Volume 64:Number 1(2023)
- Issue Display:
- Volume 64, Issue 1 (2023)
- Year:
- 2023
- Volume:
- 64
- Issue:
- 1
- Issue Sort Value:
- 2023-0064-0001-0000
- Page Start:
- 320
- Page End:
- 327
- Publication Date:
- 2023-01
- Subjects:
- Acute ischemic stroke -- computed tomography -- perfusion -- target mismatch -- ABC/2 method
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1177/02841851211069778 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24206.xml