Systematic review, meta-analysis and single-centre experience of the diagnostic accuracy of intraoperative near-infrared indocyanine green-fluorescence in detecting pancreatic tumours. Issue 11 (November 2022)
- Record Type:
- Journal Article
- Title:
- Systematic review, meta-analysis and single-centre experience of the diagnostic accuracy of intraoperative near-infrared indocyanine green-fluorescence in detecting pancreatic tumours. Issue 11 (November 2022)
- Main Title:
- Systematic review, meta-analysis and single-centre experience of the diagnostic accuracy of intraoperative near-infrared indocyanine green-fluorescence in detecting pancreatic tumours
- Authors:
- Rompianesi, Gianluca
Montalti, Roberto
Giglio, Mariano C.
Ceresa, Carlo D.L.
Nasto, Riccardo A.
De Simone, Giuseppe
Troisi, Roberto I. - Abstract:
- Abstract: Background: During pancreatic resections assessing tumour boundaries and identifying the ideal resection margins can be challenging due to the associated pancreatic gland inflammation and texture. This is particularly true in the context of minimally invasive surgery, where there is a very limited or absent tactile feedback. Indocyanine green (ICG) fluorescence imaging can assist surgeons by simply providing valuable real-time intraoperative information at low cost with minimal side effects. This meta-analysis summarises the available evidence on the use of near-infrared fluorescence imaging with ICG for the intraoperative visualization of pancreatic tumours (PROSPERO ID: CRD42021247203). Methods: MEDLINE, Embase, and Web Of Science electronic databases were searched to identify manuscripts where ICG was intravenously administered prior to or during pancreatic surgery and reporting the prevalence of pancreatic lesions visualised through fluorescence imaging. Results: Six studies with 7 series' reporting data on 64 pancreatic lesions were included in the analysis. MINOR scores ranged from 6 to 10, with a median of 8. The most frequent indications were pancreatic adenocarcinoma and neuroendocrine tumours. In most cases (67.2%) ICG was administered during surgery. ICG fluorescence identified 48/64 lesions (75%) with 81.3% accuracy, 0.788 (95%CI 0.361–0.961) sensitivity, 1 (95%CI 0.072–1) specificity and positive predictive value of 0.982 (95%CI 0.532–1). In line withAbstract: Background: During pancreatic resections assessing tumour boundaries and identifying the ideal resection margins can be challenging due to the associated pancreatic gland inflammation and texture. This is particularly true in the context of minimally invasive surgery, where there is a very limited or absent tactile feedback. Indocyanine green (ICG) fluorescence imaging can assist surgeons by simply providing valuable real-time intraoperative information at low cost with minimal side effects. This meta-analysis summarises the available evidence on the use of near-infrared fluorescence imaging with ICG for the intraoperative visualization of pancreatic tumours (PROSPERO ID: CRD42021247203). Methods: MEDLINE, Embase, and Web Of Science electronic databases were searched to identify manuscripts where ICG was intravenously administered prior to or during pancreatic surgery and reporting the prevalence of pancreatic lesions visualised through fluorescence imaging. Results: Six studies with 7 series' reporting data on 64 pancreatic lesions were included in the analysis. MINOR scores ranged from 6 to 10, with a median of 8. The most frequent indications were pancreatic adenocarcinoma and neuroendocrine tumours. In most cases (67.2%) ICG was administered during surgery. ICG fluorescence identified 48/64 lesions (75%) with 81.3% accuracy, 0.788 (95%CI 0.361–0.961) sensitivity, 1 (95%CI 0.072–1) specificity and positive predictive value of 0.982 (95%CI 0.532–1). In line with the literature, ICG fluorescence identified 5/6 (83.3%) of pancreatic lesions during robotic pancreatic resections performed at our Institution. Conclusion: This meta-analysis is the first summarising the results of ICG immunofluorescence in detecting pancreatic tumours during surgery, showing good accuracy. Additional research is needed to define optimal ICG administration strategies and fluorescence intensity cut-offs. … (more)
- Is Part Of:
- HPB. Volume 24:Issue 11(2022)
- Journal:
- HPB
- Issue:
- Volume 24:Issue 11(2022)
- Issue Display:
- Volume 24, Issue 11 (2022)
- Year:
- 2022
- Volume:
- 24
- Issue:
- 11
- Issue Sort Value:
- 2022-0024-0011-0000
- Page Start:
- 1823
- Page End:
- 1831
- Publication Date:
- 2022-11
- Subjects:
- Liver -- Diseases -- Periodicals
Biliary tract -- Diseases -- Periodicals
Pancreas -- Diseases -- Periodicals
616.362005 - Journal URLs:
- https://www.journals.elsevier.com/hpb/ ↗
http://www.hpbonline.org/current ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1477-2574 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1016/j.hpb.2022.05.004 ↗
- Languages:
- English
- ISSNs:
- 1365-182X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4335.262340
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 24216.xml