Can guided wave ultrasound predict bone mechanical properties at the femoral neck in patients undergoing hip arthroplasty?. (December 2022)
- Record Type:
- Journal Article
- Title:
- Can guided wave ultrasound predict bone mechanical properties at the femoral neck in patients undergoing hip arthroplasty?. (December 2022)
- Main Title:
- Can guided wave ultrasound predict bone mechanical properties at the femoral neck in patients undergoing hip arthroplasty?
- Authors:
- Behforootan, Sara
Thorniley, Madelaine
Minonzio, Jean-Gabriel
Boughton, Oliver
Karia, Monil
Bhattacharya, Rajarshi
Hansen, Ulrich
Cobb, Justin
Abel, Richard - Abstract:
- Abstract: The bone quality of patients undergoing hip replacement surgery is poorly predicted by radiographs alone. With better bone quality information available to a surgeon, the operation can be performed more safely. The aim of this study was to investigate whether ultrasound signals of cortical bone at peripheral sites such as the tibia and radius can be used to predict the compressive mechanical properties of cortical bone at the femoral neck. We recruited 19 patients undergoing elective hip arthroplasty and assessed the radius and tibia of these patients with the Azalée guided wave ultrasound to estimate the porosity and thickness of the cortex. Excess bone tissues were collected from the femoral neck and the compressive mechanical properties of the cortex were characterised under a mechanical loading rig to determine stiffness, ultimate strength, and density. The correlations between the ultrasound measurements and mechanical properties were analysed using linear regression, Pearson correlation statistics, and multiple regression analysis. Cortical mechanical properties were weakly to moderately correlated with the ultrasound measurements at various sites ( R 2 = 0.00–0.36). The significant correlations found were not consistent across all 4 peripheral measurement sites. Additionally, weak to moderate ability of the ultrasound to predict mechanical properties at the neck of femur with multiple regression analysis was found ( R 2 = 0.00–0.48). Again, this wasAbstract: The bone quality of patients undergoing hip replacement surgery is poorly predicted by radiographs alone. With better bone quality information available to a surgeon, the operation can be performed more safely. The aim of this study was to investigate whether ultrasound signals of cortical bone at peripheral sites such as the tibia and radius can be used to predict the compressive mechanical properties of cortical bone at the femoral neck. We recruited 19 patients undergoing elective hip arthroplasty and assessed the radius and tibia of these patients with the Azalée guided wave ultrasound to estimate the porosity and thickness of the cortex. Excess bone tissues were collected from the femoral neck and the compressive mechanical properties of the cortex were characterised under a mechanical loading rig to determine stiffness, ultimate strength, and density. The correlations between the ultrasound measurements and mechanical properties were analysed using linear regression, Pearson correlation statistics, and multiple regression analysis. Cortical mechanical properties were weakly to moderately correlated with the ultrasound measurements at various sites ( R 2 = 0.00–0.36). The significant correlations found were not consistent across all 4 peripheral measurement sites. Additionally, weak to moderate ability of the ultrasound to predict mechanical properties at the neck of femur with multiple regression analysis was found ( R 2 = 0.00–0.48). Again, this was inconsistent across the different anatomical sites. Overall, the results demonstrate the need for ultrasound scans to be collected directly from clinically relevant sites such as the femoral neck due to the inconsistency of mechanical properties across various sites. … (more)
- Is Part Of:
- Journal of the mechanical behavior of biomedical materials. Volume 136(2022)
- Journal:
- Journal of the mechanical behavior of biomedical materials
- Issue:
- Volume 136(2022)
- Issue Display:
- Volume 136, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 136
- Issue:
- 2022
- Issue Sort Value:
- 2022-0136-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-12
- Subjects:
- Ultrasound -- Guided wave -- Osteoarthritis -- Bone -- Cortical bone -- Mechanical properties
Biomedical materials -- Periodicals
Biomedical materials -- Mechanical properties -- Periodicals
Biomedical materials
Biomedical materials -- Mechanical properties
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17516161 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jmbbm.2022.105468 ↗
- Languages:
- English
- ISSNs:
- 1751-6161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5015.809000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24213.xml